Browse > Article
http://dx.doi.org/10.12989/scs.2017.23.1.067

Numerical analysis of tilted angle shear connectors in steel-concrete composite systems  

Khorramian, Koosha (Department of Civil Engineering, Sharif University of Technology)
Maleki, Shervin (Department of Civil Engineering, Sharif University of Technology)
Shariati, Mahdi (Faculty of Civil Engineering, University of Tabriz)
Jalali, Abdolrahim (Faculty of Civil Engineering, University of Tabriz)
Tahir, M.M. (UTM Construction Research Centre, Faculty of Civil Engineering, Institute for Smart Infrastructure and Innovative Construction, UTM)
Publication Information
Steel and Composite Structures / v.23, no.1, 2017 , pp. 67-85 More about this Journal
Abstract
This study investigates numerically the behavior of tilted angle shear connectors embedded in solid concrete slabs. Two different tilted angle connectors were used, titled angle with 112.5 and 135 degrees between the angle leg and steel beam flange. A nonlinear finite element model was developed to simulate and validate the experimental push-out tests. Parametric studies were performed to investigate the variations in concrete strength and connector's dimensions. The results indicate that the ultimate strength of a tilted angle shear connector is directly related to the square root of the concrete compressive strength. The effects of variations in the geometry of tilted angle connectors on the shear capacity are discussed in details. Based on the numerical analyses, two equations are proposed to estimate the ultimate capacity of tilted angle shear connectors of 112.5 and 135 degrees in the defined range of parameters.
Keywords
shear connector; composite; tilted angle; push-out test; finite element method;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Muhammad, N.Z., Shafaghat, A., Keyvanfar, A., Majid, M.Z.A., Ghoshal, S., Yasouj, S.E.M., Ganiyu, A.A., Kouchaksaraei, M.S., Kamyab, H. and Taheri, M.M. (2016), "Tests and methods of evaluating the self-healing efficiency of concrete: A review", Construct. Build. Mater., 112, 1123-1132.   DOI
2 Nakajima, A., Saiki, I., Kokai, M., Doi, K., Takabayashi, Y. and Ooe, H. (2003), "Cyclic shear force-slip behavior of studs under alternating and pulsating load condition", Eng. Struct., 25(5), 537-545.   DOI
3 Oguejiofor, E. and Hosain, M. (1997), "Numerical analysis of push-out specimens with perfobond rib connectors", Comput. Struct., 62(4), 617-624.   DOI
4 Razaqpur, A.G. and Nofal, M. (1989), "A finite element for modelling the nonlinear behavior of shear connectors in composite structures", Comput. Struct., 32(1), 169-174.   DOI
5 Safa, M., Shariati, M., Ibrahim, Z., Toghroli, A., Baharom, S.B., Nor, N.M. and Petkovic, D. (2016), "Potential of adaptive neuro fuzzy inference system for evaluating the factors affecting steelconcrete composite beam's shear strength", Steel Compos. Struct., Int. J., 21(3), 679-688.   DOI
6 Shah, S., Sulong, N.R., Shariati, M., Khan, R. and Jumaat, M. (2016), "Behavior of steel pallet rack beam-to-column connections at elevated temperatures", Thin-Wall. Struct., 106, 471-483.   DOI
7 Shariati, A. and Schumacher, T. (2015), "Oversampling in virtual visual sensors as a means to recover higher modes of vibration, 41st Annual Review of Progress in Quantitative Nondestructive Evaluation, Volume 34, AIP Publishing.
8 Shariati, A. and Schumacher, T. (2016), "Eulerian-based virtual visual sensors to measure dynamic displacements with subpixel accuracy of structures and mechanical systems", J. Struct. Control Health Monitor.
9 Shariati, M., Ramli Sulong, N.H., Suhatril, M., Shariati, A., Arabnejad, M.M.K. and Sinaei, H. (2012b), "Behaviour of Cshaped angle shear connectors under monotonic and fully reversed cyclic loading: An experimental study", Mater. Des., 41, 67-73.   DOI
10 Shariati, M., Ramli Sulong, N.H. and Arabnejad Khanouki, M.M. (2012a), "Experimental assessment of channel shear connectors under monotonic and fully reversed cyclic loading in high strength concrete", Mater. Des., 34, 325-331.   DOI
11 Shariati, M., Ramli Sulong, N., Suhatril, M., Shariati A., Arabnejad Khanouki, M. and Sinaei, H. (2012c), "Fatigue energy dissipation and failure analysis of channel shear connector embedded in the lightweight aggregate concrete in composite bridge girders", Proceedings of the 5th International Conference on Engineering Failure Analysis, The Hague, The Netherlands, July.
12 Shariati, M., Ramli Sulong, N.H., Suhatril, M., Shariati, A., Arabnejad Khanouki, M.M. and Sinaei, H. (2013), "Comparison of behaviour between channel and angle shear connectors under monotonic and fully reversed cyclic loading", Construct. Build. Mater., 38, 582-593.   DOI
13 Shariati, A., Shariati, M., Ramli Sulong, N.H., Suhatril, M., Arabnejad Khanouki, M.M. and Mahoutian, M. (2014), "Experimental assessment of angle shear connectors under monotonic and fully reversed cyclic loading in high strength concrete", Construct. Build. Mater., 52, 276-283.   DOI
14 Shariati, M., Ramli Sulong, N.H., Shariati, A. and Khanouki, M.A. (2015a), "Behavior of V-shaped angle shear connectors: experimental and parametric study", Mater. Struct., 1-18.
15 Shariati, A., Schumacher, T. and Ramanna, N. (2015b), "Eulerianbased virtual visual sensors to detect natural frequencies of structures", J. Civil Struct. Health Monitor., 5(4), 457-468.   DOI
16 Shehu, I. and Awal, A. (2012), "Mechanical properties of concrete incorporating high volume palm oil fuel ash", Adv. Mater. Res., 599, Trans Tech Publications.
17 Arabnejad Khanouki, M.M., Ramli Sulong, N.H. and Shariati, M. (2011), "Behavior of through beam connections composed of CFSST columns and steel beams by finite element studying", Adv. Mater. Res., 168, 2329-2333.
18 Abdul Awal, A.S. (1988), "Failure mechanism of prepacked concrete", J. Struct. Eng., 114(3), 727-732.   DOI
19 Abdul Awal, A.S. (1992), "Creep recovery of prepacked aggregate concrete", J. Mater. Civil Eng., 4(3), 320-325.   DOI
20 Arabnejad Khanouki, M.M., Ramli Sulong, N.H. and Shariati, M. (2010), "Investigation of seismic behaviour of composite structures with concrete filled square steel tubular (CFSST) column by push-over and time-history analyses", Proceedings of the 4th International Conference on Steel and Composite Structures, Sydney, Australia, July.
21 Choi, S.M., Tateishi, K., Uchida, D., Asano, K. and Kobayashi, K. (2008), "Fatigue strength of angle shape shear connector used in steel-concrete composite slab", Int. J. Steel Struct., 8(3), 199-204.
22 Faella, C., Martinelli, E. and Nigro, E. (2002), "Steel and concrete composite beams with flexible shear connection: "exact" analytical expression of the stiffness matrix and applications", Comput. Struct., 80(11), 1001-1009.   DOI
23 Cornelissen, H., Hordijk, D. and Reinhardt, H. (1986), "Experimental determination of crack softening characteristics of normalweight and lightweight concrete", HERON, 31(2), 1986.
24 Daie, M., Jalali, A., Suhatril, M., Shariati, M., Arabnejad, Khanouki, M.M., Shariati, A. and Kazemi Arbat, P. (2011), "A new finite element investigation on pre-bent steel strips as damper for vibration control", Int. J. Phys. Sci., 6(36), 8044-8050.
25 Ellobody, E. and, Lam, D. (2002), "Modeling of headed stud in steel-precast composite beams", Steel Compos. Struct., Int. J., 2(5), 355-378.   DOI
26 Hafizah, N.A.K., Bhutta, M.A.R., Jamaludin, M.Y., Warid, M.H., Ismail, M., Rahman, M.S., Yunus, I. and Azman, M. (2014), "Kenaf fiber reinforced polymer composites for strengthening RC beams", J. Adv. Concrete Technol., 12(6), 167-177.   DOI
27 Khalilian, M. (2013), "The assessment of shear capacity of angle shear connectors", Master; Sharif University of Technology.
28 Hillerborg, A., Modeer, M. and Petersson, P.-E. (1976), "Analysis of crack formation and crack growth in concrete by means of fracture mechanics and finite elements", Cement Concrete Res., 6(6), 773-781.   DOI
29 Hossain, M. and Awal, A.A. (2011), "Experimental validation of a theoretical model for flexural modulus of elasticity of thin cement composite", Construct. Build. Mater., 25(3), 1460-1465.   DOI
30 Institution, B.S. (2004), Eurocode 2: Design of Concrete Structures: Part 1-1: General Rules and Rules for Buildings, British Standards Institution.
31 Kwak, H.-G. and Hwang, J.-W. (2010), "FE model to simulate bond-slip behavior in composite concrete beam bridges", Comput. Struct., 88(17-18), 973-984.   DOI
32 Toghrolia, A., Mohammadhassani, M., Shariatib, M., Suhatrilc, M., Ibrahimd, Z. and Sulong, N.H.R. (2014), "Prediction of shear capacity of channel shear connectors using the ANFIS model", Steel Compos. Struct., Int. J., 17(5), 623-639.   DOI
33 Soltani, M., Topa, A., Karim, M.R. and Sulong, N.R. (2016), "Crashworthiness of G4 (2W) guardrail system: a finite element parametric study", Int. J. Crashworth., 1-21.
34 Tahmasbi, F., Maleki, S., Shariati, M., Ramli Sulong, N.H. and Tahir, M.M. (2016), "Shear capacity of C-shaped and L-shaped angle shear connectors", PLOS ONE, 11(8), e0156989.   DOI
35 Toghroli, A., Suhatril, M., Ibrahim, Z., Safa, M., Shariati M. and Shamshirband, S. (2016), "Potential of soft computing approach for evaluating the factors affecting the capacity of steel-concrete composite beam", J. Intel. Manuf., 1-9.
36 Walker, C., Miller, T., Gupta, R., Shariati, A. and Schumacher, T. (2016), "Development of virtual visual sensors applications to wood structural health monitoring", ASTM J. Test. Eval.
37 Khorramian, K., Maleki, S., Shariati, M. and Ramli Sulong, N.H. (2015), "Behavior of tilted angle shear connectors", PLoS ONE, 10(12), e0144288.   DOI
38 Wang, A.J. and Chung, K.F. (2008), "Advanced finite element modelling of perforated composite beams with flexible shear connectors", Eng. Struct., 30(10), 2724-2738.   DOI
39 Yahya Kasim Al-Darzi, S. and Chen, A. (2006), "Development of hybrid bridges: State of arts and conceptual design", J. Appl. Sci., 6(13), 2799-2803.   DOI
40 Yan, J.-B., Liew, J.R., Zhang, M.-H. and Sohel, K. (2015), "Experimental and analytical study on ultimate strength behavior of steel-concrete-steel sandwich composite beam structures", Mater. Struct., 48(5), 1523-1544.   DOI
41 Slutter, R. and Driscoll, G.C. (1965), "Flexural strength of steel and concrete composite beams", J. Struct. Eng., ASCE, 71-99.
42 Maleki, S. (2002), "Effect of deck and support stiffness on seismic response of slab-girder bridges", Eng. Struct., 24(2), 219-226.   DOI
43 Lam, D. and EI-Lobody, E. (2001), "Finite element modelling of headed stud shear connectors in steel-concrete composite beam", Elsevier Science Ltd.
44 Lam, D. and El-Lobody, E. (2005), "Behavior of headed stud shear connectors in composite beam", J. Struct. Eng., 131, 96-107.   DOI
45 Loh, H., Uy, B. and Bradford, M. (2006), "The effects of partial shear connection in composite flush end plate joints Part I--experimental study", J. Construct. Steel Res., 62(4), 378-390.   DOI
46 Mirza, O. and Uy, B. (2009), "Behaviour of headed stud shear connectors for composite steel-concrete beams at elevated temperatures", J. Construct. Steel Res., 65(3), 662-674.   DOI
47 Maleki, S. and Bagheri, S. (2008a), "Behavior of channel shear connectors, Part I: Experimental study", J. Construct. Steel Res., 64(12), 1333-1340.   DOI
48 Maleki, S. and Bagheri, S. (2008b), "Behavior of channel shear connectors, Part II: Analytical study", J. Construct. Steel Res., 64(12), 1341-1348.   DOI
49 Maleki, S. and Mahoutian, M. (2009), "Experimental and analytical study on channel shear connectors in fiber-reinforced concrete", J. Construct. Steel Res., 65(8-9), 1787-1793.   DOI
50 Muhammad, B., Ismail, M., Bhutta, M.A.R. and Abdul-Majid, Z. (2012), "Influence of non-hydrocarbon substances on the compressive strength of natural rubber latex-modified concrete", Construct. Build. Mater., 27(1), 241-246.   DOI
51 Muhammad, N.Z., Keyvanfar, A., Majid, M.Z.A., Shafaghat, A. and Mirza, J. (2015), "Waterproof performance of concrete: A critical review on implemented approaches", Construct. Build. Mater., 101, 80-90.   DOI