Browse > Article
http://dx.doi.org/10.12989/scs.2016.22.5.1039

Dynamic characteristics and wind-induced vibration coefficients of purlin-sheet roofs  

Zhang, Yingying (State Key Laboratory for GeoMechanics and Deep Underground Engineering, Jiangsu Key Laboratory of Environmental Impact and Structural Safety in Engineering, China University of Mining and Technology)
Song, Xiaoguang (Shandong Academy of building research)
Zhang, Qilin (College of Civil Engineering, Tongji University)
Publication Information
Steel and Composite Structures / v.22, no.5, 2016 , pp. 1039-1054 More about this Journal
Abstract
This paper presents the dynamic characteristics analysis of the purlin-sheet roofs by the random vibration theories. Results show that the natural vibration frequency of the purlin-sheet roof is low, while the frequencies and mode distributions are very intensive. The random vibration theory should be used for the dynamic characteristics of the roof structures due to complex vibration response. Among the first 20th vibration modes, the first vibration mode is mainly the deformations of purlins, while the rest modes are the overall deformations of the roof. In the following 30th modes, it mainly performs unilateral local deformations of the roof. The frequency distribution of the first 20th modes varies significantly while those of the following 30th modes are relatively sensitive. For different parts, the contributions of vibration modes on the vibration response are different. For the part far from the roof ridge, only considering the first 5th modes can reflect the wind-induced vibration response. For the part near the ridge, at least the first 12 modes should be considered, due to complex vibration response. The wind vibration coefficients of the upwind side are slightly higher than that of the leeward side. Finally, the corresponding wind vibration coefficient for the purlin-sheet roof is proposed.
Keywords
purlin sheet roof; random vibration theory; dynamic characteristic; wind-induced vibration coefficient;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 Martins, N.E., Martin, P.B. and Baskaran, A. (2016), "Application of statistical models to predict roof edge suctions based on wind speed", J. Wind Eng. Ind. Aerod., 150, 42-53.   DOI
2 Nakayama, M., Sasaki, Y., Masuda, K., Ogawa, T. (1998), "An efficient method for selection of vibration modes contributory to wind response on dome-like roofs", J. Wind Eng. Ind. Aerod., 73(1), 31-43.   DOI
3 Pei, Y.Z. (2009), Research on Wind Loads and Wind-induced Responses of Large-span Aircraft Maintenance Hangars, Tsinghua University, Beijing, China.
4 Ren, C., Zhao, X.Z. and Chen, Y.Y. (2016), "Buckling behaviour of partially restrained cold-formed steel zed purlins subjected to transverse distributed uplift loading", Eng. Struct., 114, 14-24.   DOI
5 Robertson, A., Hoxey, R., Short, J., Ferguson, W.A. and Blackmore, P.A. (1998), "Prediction of structural loads from fluctuating wind pressures: Validation from full-scale force and pressure measurements", J. Wind Eng. Ind. Aerod., 74(2), 631-640.
6 Shu, X.L. and Zhou, D. (2003), "AR model of wind speed time series and its rapid implementation", Spatial Struct., 9(4), 27-32.
7 Sun, X., Lin, B., Wu, X., Sun, X.Y., Lin, B., Wu, X.R., Wu, Y. and Shen, S.Z. (2008), "Application of numerical wind tunnel to simulate wind load on long-span roof", Build. Struct., 38(10), 83-86.
8 Surry, D., Sinno, R.R., Nail, B., Ho, T., Farquhar, S. and Kopp, G. (2007), "Structurally effective static wind loads for roof panels", J. Struct. Eng., 133(6), 871-885.   DOI
9 Tamura, T. (1999), "Reliability on CFD estimation for wind-structure interaction problems", J. Wind Eng. Ind. Aerod., 81(1-3), 117-143.   DOI
10 Ahmad, S. and Kumar, K. (2002), "Effect of geometry on wind pressures on low-rise hip roof buildings", J. Wind Eng. Ind. Aerod., 90(7), 755-779.   DOI
11 Cai, J.G., Feng, J., Xu, Y.X. and Wang, K. (2013a), "Investigation of the static and dynamic behavior of a deployable hybrid grid shell", Adv. Struct. Eng., 16(6), 1103-1111.   DOI
12 Cai, J.G., Gu, L.M., Xu, Y.X. Feng, J. and Zhang, J. (2013b), "Non-linear stability analysis of hybrid grid shells", Int. J. Struct. Stab. Dy., 13(1), Paper No. 1350006.
13 Tieleman, H.W., Surry, D. and Lin, J.X. (1994), "Characteristics of mean and fluctuating pressure coefficients under corner (delta wing) vortices", J. Wind Eng. Ind. Aerod., 52, 263-275.   DOI
14 Uematsu, Y., Watanabe, K., Sasaki, A., Yamada, M. and Hongo, T. (1999), "Wind-induced dynamic response and resultant load estimation of a circular flat roof", J. Wind Eng. Ind. Aerod., 83(1), 251-261.   DOI
15 Uematsu, Y., Yamada, M. and Karasu, A. (1997), "Design wind loads for structural frames of flat long-span roofs: Gust loading factor for the beams supporting roofs", J. Wind Eng. Ind. Aerod., 66(1), 35-50.   DOI
16 Xu, A., Fu, J.Y., Zhao, R.H. and Wu, J.R. (2010), "Field measurements of typhoons according to civil engineering research", Acta Aerodynamica Sinica, 28(1), 23-31.
17 Zhou, W., Chen, Y., Peng, B., Yahg, H., Yu, H., Liu, H. and He, X. (2014), "Air damping analysis in comb microaccelerometer", Adv. Mech. Eng., 2014, Article ID 373172, 6 p.
18 Yuan, W.B., Cheng, S.S. and Li, L.Y. (2014), "Web-flange distortional buckling of partially restrained coldformed steel purlins under uplift loading", Int. J. Mech. Sci., 89, 476-481.   DOI
19 Zhang, X.T. (2006), Structural Wind Engineering, China Architecture and Building Press, Beijing, China.
20 Zhang, L. and Tong, G.S. (2016), "Lateral buckling of simply supported C- and Z-section purlins with top flange horizontally restrained", Thin-Wall. Struct., 99, 155-167.   DOI
21 Zhou, W., Yu, H.J., Zeng, J., Peng, B., Zeng, Z., He, X. and Liu, Y. (2015), "Improving the dynamic performance of capacitive micro-accelerometer through electrical damping", Microsyst. Technol., 22(12), 2961-2969. DOI: 10.1007/s00542-015-2694-1
22 Zhu, J., Chen, J.K. and Ren, C. (2014), "Numerical study on the moment capacity of zed-section purlins under uplift loading", Struct. Eng. Mech., Int. J., 49(2), 147-161.   DOI
23 Cai, J.G., Xu, Y.X., Feng, J. and Zhang, J. (2013c), "Design and analysis of a glass roof structure", Struct. Des. Tall Spec., 22(8), 677-686.   DOI
24 Cai, J.G., Zhou, Y., Xu, Y.X. and Feng, J. (2013d), "Non-linear stability analysis of a hybrid barrel vault roof", Steel Compos. Struct., Int. J., 14(6), 571-586.   DOI
25 Cai, J.G., Chao, J., Deng, X.W., Feng, J. and Xu, Y. (2015), "Static analysis of a radially retractable hybrid grid shell in the closed position", Steel Compos. Struct., Int. J., 18(6), 1391-1404.   DOI
26 Fu, J., Zhao, R., Xu, A. and Wu, J.R. (2010), "Wind tunnel and full-scale study of wind effects on a large roof structure", J. Hunan Univ. (Nat. Sci.), 37(9), 12-18
27 Cope, A.D., Gurley, K.R., Gioffre, M. and Reinhold, T.A. (2005), "Low-rise gable roof wind loads:Characterization and stochastic simulation", J. Wind Eng. Ind. Aerod., 93(9), 719-738.   DOI
28 Davenport, A.G. (1967), "Gust loading factors", J. Struct. Div., 93(3), 11-34.
29 Farquhar, S., Kopp, G.A. and Surry, D. (2005), "Wind tunnel and uniform pressure tests of a standing seam metal roof model", J. Struct. Eng., 131(4), 650-659.   DOI
30 GB50009-2012 (2012), Load code for the design of building structures; China Architecture & Building Press, Beijing, China.
31 Ginger, J.D. (2004), "Fluctuating wind loads across gable-end buildings with planar and curved roofs", Wind Struct., Int. J., 7(6), 359-372.   DOI
32 Habte, F., Mooneghi, M.A., Chowdhury, A.G. and Irwin, P. (2015), "Full-scale testing to evaluate the performance of standing seam metal roofs under simulated wind loading", Eng. Struct., 105, 231-248.   DOI
33 Huang, B.C. and Wang, C.J. (2008), Principle and Application of Structural Wind Resistance Analysis, Tongji University Press, Shanghai, China.
34 Lin, J.X., Surry, D. and Tieleman, H.W. (1995), "The distribution of pressure near roof corners of flat roof low buildings", J. Wind Eng. Ind. Aerod., 56(2), 235-265.   DOI
35 Jacklin, R.B., El Damatty, A.A. and Dessouki, A.A. (2014), "Finite-element modeling of a light-framed wood roof structure", Wind Struct., Int. J., 19(6), 603-621.   DOI
36 Jubayer, C.M. and Hangan, H. (2014), "Numerical simulation of wind effects on a stand-alone ground mounted photovoltaic (PV) system", J. Wind Eng. Ind. Aerod., 134, 56-64.   DOI
37 Kasperski, M. (2009), "Specification of the design wind load-A critical review of code concepts", J. Wind Eng. Ind. Aerod., 97(7), 335-357.   DOI
38 Krentowski, J. (2014), "Steel roofing disaster and the effect of the failure of butt joints", Eng. Fail Anal., 45, 245-251.   DOI
39 Li, Y.Q. and Dong, S.L. (2001), "Random wind load simulation and computer program for large-span spatial structures", Spatial Struct., 7(3), 3-11.
40 Liu, M., Chen, X.Z. and Yang, Q.S. (2016), "Characteristics of dynamic pressures on a saddle type roof in various boundary layer flow", J. Wind Eng. Ind. Aerod., 150, 1-14.   DOI
41 Lou, W., Li, B. and Lu, F. (2002), "Fitting formula to wind pressure distribution on long-span roofs and wind load suggestion", J. Tongji Univ., 30(5), 588-593.
42 Lovisa, A.C., Wang, V.Z., Henderson, D.J. and Ginger, J.D. (2013), "Development and validation of a numerical model for steel roof cladding subject to static uplift loads", Wind Struct., Int. J., 17(5), 495-513.   DOI
43 Lu, F., Lou, W.J. and Sun, B.N. (2002), "Wind-induced dynamic response and wind load factor for longspan flat roof structures", Eng. Mech., 19(2), 52-57.