Browse > Article
http://dx.doi.org/10.12989/scs.2016.20.4.833

Retrofitting of RC girders using pre-stressed CFRP sheets  

Bansal, Prem Pal (Department of Civil Engineering, Thapar University)
Sharma, Raju (Department of Civil Engineering, Thapar University)
Mehta, Ankur (Department of Civil Engineering, Thapar University)
Publication Information
Steel and Composite Structures / v.20, no.4, 2016 , pp. 833-849 More about this Journal
Abstract
Pre-stressing of existing structures using steel cables, FRP cables or FRP laminates has been successfully tried in the past. Retrofitting of beams using pre-stressed laminates does not utilize the full strength of the FRP due to de-bonding of the laminates before the fibre fracture. In the present study attempt has been made to overcome this problem by replacing the FRP laminates by the FRP sheets. In the present paper the effect of initial damage level and pre-stress level on strength, stiffness, cracking behaviour and failure mode of girders retrofitted using pre-stressed CFRP sheets has been studied. The results indicate that rehabilitation of initially damaged girders by bonding pre-stressed CFRP sheets improves the flexural behaviour of beams appreciably. However, it has been observed that with increase in pre-stressing force the load carrying capacity of the girders increases up to a particular level up to which the mode of failure is fibre fracture. Thereafter, the mode of failure shifts from fibre fracture to de-bonding and there is no appreciable increase in load carrying capacity with further increase in pre-stressing force.
Keywords
retrofitting; pre-stressed FRP sheets; girders; initial damage level; pre-stressing force level;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 ACI 440-02 (2002), Guide for the design and construction of externally bonded FRP system for strengthening concrete structures; Reported by ACI-440.
2 Bank, L.C. (2006), Composites for Construction: Structural Design with FRP Materials, John Wiley & Sons.
3 Bansal, P.P., Kumar, M. and Kaushik, S.K. (2011), "Effect of initial stress levels on strength parameters of reinforced concrete beams retrofitted using ferrocement jackets", ASTM J. Test. Eval., 39(5), 879-888.
4 Bonacci, J.F. and Maalej, M. (2000), "Externally bonded FRP for rehabilitation of corrosion damaged concrete beams", ACI Struct. J., 97(5), 703-711.
5 Chaallal, O., Nollet, M.J. and Saleh, K. (1998), "Use of CFRP strips for flexure and shear strengthening of RC members", Proceedings of the Second International Conference on Composites in Infrastructure, Tucson, AZ, USA, January, pp. 249-159.
6 Diab, H., Wu, Z.S. and Iwashita, K. (2009), "Short and long-term bond performance of prestressed FRP sheet anchorages", Eng. Struct., 31(5), 1241-1249.   DOI
7 El Maaddawy, T., Soudki, K. and Topper, T. (2007), "Performance evaluation of carbon fiber reinforced polymer-repaired beams under corrosive environmental conditions", ACI Struct. J., 104(1), 3-11.
8 Hutchinson, R., Abdelrahman, A. and Rizkalla, S. (1998), "Shear strengthening using CFRP sheets for prestressed concrete bridge girders in Manitoba, Canada", Proceedings of the Second International Conference on Composites in Infrastructure, Tucson, AZ, USA, January, pp. 261-275.
9 Kim, N.E., Kim, H.Y. and Kim, S.H. (2015), "Experimental and analytical investigations for behaviors of RC beams strengthened with tapered CFRPs", Struct. Eng. Mech., Int. J., 53(6), 1067-1081.   DOI
10 Michels, J., Martinelli, E., Czaderski, C. and Motavalli, M. (2014), "Prestressed CFRP strips with gradient anchorage for structural concrete retrofitting: Experiments and numerical modeling", Polymers, 6(1), 114-131.   DOI
11 Mukherjee, A. and Gopal, G.L. (2009), "Performance of reinforced concrete beams externally prestressed with fiber composites", Construct. Build. Mater., 23(2), 822-828.   DOI
12 Mukherjee, A., Bagadi, S. and Rai, G. (2009), "Semianalytical modeling of concrete beams rehabilitated with externally prestressed composites", J. Compos. Construct., 13(2), 74-81.   DOI
13 Panjehpour, M., Ali, A.A.A. and Aznieta, F.N. (2014), "Energy absorption of reinforced concrete deep beams strengthened with CFRP sheet", Steel Compos. Struct., Int. J., 16(5), 481-489.   DOI
14 Park, J.W. and Yoo, J.H. (2015), "Flexural and compression behavior for steel structures strengthened with Carbon Fiber Reinforced Polymers (CFRPs) sheet", Steel Compos. Struct., Int. J., 19(2), 441-465.   DOI
15 Park, J., Park, Y., Yoo, Y. and Jung, W. (2005), "Strengthening capacity of RC beams tension-strengthened with carbon plate", Proc Korea Concrete Society, 17(1), 279-282.
16 Soudki, K.A., Sherwood, T. and Masoud, S. (2000), "FRP repair of corrosion-damaged reinforced concrete beams", Report; Department of Civil Engineering, University of Waterloo, Waterloo, ON, Canada.
17 Pellegrino, C. and Modena, C. (1998), "Flexural behaviour of RC and PC beams strengthened with external pretensioned FRP laminates", Proceedings of Fracture Mechanics of Concrete and Concrete Structures: Design, Assessment and Retrofitting of RC Structures, Catania, Italy, June, pp. 1235-1240.
18 Priestley, M.N. and Seible, F. (1993), "Repair of column using fiber glass/epoxy jacket and epoxy injection", SEQAD Consulting Engineers Report; Volume 04.
19 Saadatmanesh, M., Ehsani, M. and Li, M. (1994), "Strength and ductility of concrete columns externally reinforced with fiber composite straps", ACI Struct. J., 91(4), 443-446.
20 Soudki, K.A., Rteil, A.A., Al-Hammoud, R. and Topper, T.H. (2007), "Fatigue strength of fibrereinforcedpolymer-repaired beams subjected to mild corrosion", Can. J. Civil Eng., 34(3), 414-421.   DOI
21 Xiao, Y. (1998), "Shear retrofit of reinforced concrete bridge piers using prefabricated composites", Proceedings of the Second International Conference on Composites in Infrastructure, Tucson, AZ, USA, January, pp. 221-233.
22 Yoo, Y., Choi, K., Park, Y. and Kim, K. (2005), "Flexural behaviors of RC beams strengthened with externally prestressed carbon fiber plate", Proc. Korea Concrete Society, 17(1), 255-258.   DOI