Numerical analysis of partially fire protected composite slabs |
Zaharia, R.
(The "Politehnica" University of Timisoara)
Vulcu, C. (The "Politehnica" University of Timisoara) Vassart, O. (ArcelorMittal, Esch/Alzette) Gernay, T. (University of Liege) Franssen, J.M. (University of Liege) |
1 | Zhao, B., Roosefid, M. and Vassart, O. (2008), "Full scale test of a steel and concrete composite floor exposed to ISO fire", Proceedings of the 5th International Conference on Structures in Fire SiF'08, Singapore City, Singapore, May. |
2 | COSSFIRE (2006), "Connection of Steel and Composite Structures Under Natural Fire Conditions", RFCS research project RFSR-CT-2006-00028. |
3 | EN 1992-1-2 (2005), "Eurocode 2 - Design of concrete structures. Part 1-2. General rules - Structural Fire Design", CEN, Brussels. |
4 | EN 1993-1-2 (2005), "Eurocode 3 - Design of steel structures. Part 1-2. General rules - Structural Fire Design", CEN, Brussels. |
5 | EN 1994-1-2 (2005), "Eurocode 4 - Design of composite steel and concrete structures. Part 1-2. General rules - Structural Fire Design", CEN, Brussels. |
6 | Franssen, J.M. (2005), "SAFIR - A thermal/structural program modelling structures under fire", Eng J Aisc, 42(3), 143-158. |
7 | Huang, Z., Burgess, I.W. and Plank, R.J. (2002), "Modelling of six full-scale fire tests on a composite building", Struct Eng, 80(19), 30-38. |
8 | Huang, Z., Burgess, I., Plank, R. and Bailey, C. (2004), "Comparison of BRE simple design method for composite slabs in fire with non-linear FE modelling", Fire Mater, 28, 127-138. DOI ScienceOn |
9 | Li, G.Q., Guo, S.X. and Zhou, H.S. (2007) "Modelling of membrane action in floor slabs subjected to fire", Eng Struct, 29, 880-887. DOI ScienceOn |
10 | Moss, P.J., Clifton, G.C. (2004), "Modelling of the Cardington LBTF steel frame building fire tests", Fire Mater, 28, 177-198. DOI ScienceOn |
11 | SCI - Swinden Technology Centre (1999), 'The behaviour of Multi-storey steel framed buildings in fire - A European joint research programme", British Steel, Rotherham, U.K. |
12 | Simoes da Silva, L., Santiago, A., Vila Real, P. and Moore, D. (2005), "Behaviour of steel joints under fire loading", Steel Compos Struct, 5(6), 485-513. DOI ScienceOn |
13 | Vulcu, C., Gernay, Th., Zaharia, R. and Franssen, J.M. (2010), "Numerical modelling of membrane action of composite slabs in fire situation", Proceedings of 6th Intl Conference Structures in Fire, East Lansing, USA. |
14 | Wald, F., Simoes da Silva, L., Moore, D., Lennon, T., Chladna, M., Santiago, A., Benes and M., Borges, L. (2005), "Experimental behaviour of steel structure under natural fire", New Steel Construction, 13(3), 24-27. |
15 | Wald, F., Chladna, M., Moore, D., Santiago, A. and Lennon, T. (2006), "Temperature distribution in a fullscale steel framed building subjected to a antural fire", Steel Compos Struct, 6(2), 159-182. DOI ScienceOn |
16 | Wald, F., Kallerova, P., Chlouba, P., Sokol, Z., Strejcek, M., Pospisil, J., Stroner, M., Kremen, T. and Smitka, V. (2010), "Fire test on an administrative building in Mokrsko", CTU in Prague. |
17 | Wang, Y.C. (1996), "Tensile membrane action in slabs and its application to the Cardington tests", Second Cardington Conference, BRE, Watford, UK. |
18 | Yin, Y.Z. and Wang, Y.C. (2006), "Analysis of behaviour of steel beams with web openings at elevated temperatures", Steel Compos Struct, 6(1), 22-32. |
19 | Abu, A.K., Burgess, I.W. and Plank, R.J. (2008), "Slab panel vertical support and tensile membrane action in fire", Steel Compos Struct, 8(3), 217-230. DOI ScienceOn |
20 | Bailey, C.G. and Moore, D.B. (2000), "The structural behaviour of steel frames with composite floor slabs subjected to fire: Part 1: Theory", Struct Eng, 78, 9-26. |
21 | Bailey, C.G. (2001), "Membrane action of unrestrained lightly reinforced concrete slabs at large displacements", Eng Struct, 23, 470-483. DOI ScienceOn |
22 | Bailey, C.G. (2001), "Steel structures supporting composite floor slabs: design for fire", BRE Digest, 462 |
23 | Bailey , C.G., Lennon, T. and Moore, D. B. (2003), "The behaviour of a multi-storey composite steel framed building in fire", Struct Eng, 81/2, 27-36. |
24 | Bailey, C.G. (2004), "Membrane action of slab/ beam composite floor systems in fire", Eng Struct, 26, 1691-1703. DOI ScienceOn |
25 | Beard, A.N. (2000), "On a priori, blind and open comparisons between theory and experiment", Fire Safety J., 35, 63-66. DOI ScienceOn |
26 | Chlouba, J. and Wald, F. (2009), "Connection temperatures during Mokrsko fire test", Acta Polytechnica, Czech Technical University Publishing House, 49(1), 76-81. |
27 | Cadorin, J.F. and Franssen, J.M. (2003), "A tool to design steel elements submitted to compartment fires - OZone V2. Part 1: Pre- and post-flashover compartment fire model", Fire Safety J, 38, 395-427. DOI ScienceOn |
28 | Cadorin, J.F., Pintea, D., Dotreppe, J.C. and Franssen, J.M. (2003), "A tool to design steel elements submitted to compartment fires - OZone V2. Part 2: Methodology and application", Fire Safety J, Elsevier, 38, 429-451. DOI ScienceOn |