1 |
Dong, Y. (2009) "Behaviour of full-scale frames with Slim Floor slab construction under exposure in a fire resistance furnace", J Fire Prot Eng, 19(3), 197-220.
DOI
ScienceOn
|
2 |
ArcelorMittal Commercial Sections (2008), "Slim Floor, an innovative concept for floors", Long Carbon Europe Sections and Merchant Bars, Esch-sur-Alzette, Luxembourg
|
3 |
Ellobody, E. (2011) "Nonlinear behaviour of unprotected composite Slim Floor steel beams exposed to different fire conditions", Thin Wall Struct, 49(6), 762-771.
DOI
ScienceOn
|
4 |
EN 1992-1-2 (2005) "Eurocode 2-Design of concrete structures. Part 1-2. General rules - Structural Fire Design", CEN, Brussels.
|
5 |
EN 1993-1-2 (2005) "Eurocode 3-Design of steel structures. Part 1-2. General rules - Structural Fire Design", CEN, Brussels.
|
6 |
Fontana, M., Borgogno, W. (1996) "Slim Floor slabs: fire resistance and system behaviour of hollow core slabs on flexible beams", Composite Construction in Steel and Concrete, Proceedings of Engineering Foundation Conference, ASCE, Irsee, Germany.
|
7 |
Franssen, J. M. (2005) "SAFIR. A Thermal/Structural Program Modelling Structures under Fire", Eng J Aisc, 42(3), 143-158.
|
8 |
Kim, H. J., Kim, H. Y., Park, S. Y. (2011) "An experimental study on fire resistance of Slim Floor beam", Appl Mech Mater, 82, 752-757.
DOI
|
9 |
Ma, Z., Makelainen, P. (2006) "Structural behaviour of composite Slim Floor frames in fire conditions", J Constr Steel Res, 62(12), 1282-1289.
DOI
ScienceOn
|
10 |
Newman, G. M. (1995) "Fire resistance of Slim Floor beams", J Constr Steel Res, 33(1-2), 87-100.
DOI
ScienceOn
|
11 |
Park, S., Kim, H., Kim, H., Hong, K. (2011) "Fire resistance of the Korean asymmetric Slim Floor beam depending on load ratio", J Asian Archit Build, 10(2), 413-420.
DOI
ScienceOn
|
12 |
PROFILARBED (1995), "RPS Report No 24/95 : Test au feu sur un Plancher type Slim Floor, EMPA/ETH Zurich le 6 aout 1994", Groupe Arcelor, Centre de Recherches, RPS Department, Esch-sur-Alzette, Luxembourg.
|
13 |
Simoes da Silva, Santiago, A., Vila Real, P., Moore, D. (2005), "Behaviour of steel joints under fire loading", Steel Compos Struct, 5(6), 485-513.
DOI
|
14 |
STC - Swinden Technology Centre (1999), 'The behaviour of Multi-storey steel framed buildings in fire - A European joint research programme", British Steel , Rotherham, U.K.
|
15 |
Wald, F., Simoes da Silva, L., Moore, D., Lennon, T., Chladna, M., Santiago, A., Benes, M., Borges, L. (2005), "Experimental behaviour of steel structure under natural fire", New Steel Construction, 13(3), 24-27.
|
16 |
Wang, Y. C. (1996), "Tensile membrane action in slabs and its application to the Cardington tests", Second Cardington Conference, BRE, Watford, U.K.
|
17 |
Zaharia, R., Duma, D., Vassart, O., Gernay, T., Franssen, J. M. "Simplified fire design for Slim Floor beams", Proceedings of the 6th European Conference on Steel and Composite Structures Eurosteel 2011, Budapest, Hungary, Vol. B, 1539-1544.
|
18 |
Bailey, C. G. (2003) "Large scale test on a composite Slim Floor system", Steel Compos Struct, 3(3), 153-168.
DOI
|