Field measurements of wind effects on a super high-rise building during typhoons |
Liu, Chunlei
(State Key Laboratory of Subtropical Building Science, South China University of Technology)
Xie, Zhuangning (State Key Laboratory of Subtropical Building Science, South China University of Technology) Zhang, Lele (State Key Laboratory of Subtropical Building Science, South China University of Technology) Shi, Biqing (State Key Laboratory of Subtropical Building Science, South China University of Technology) Fu, Jiyang (Guangzhou University-Tamkang University Joint Research Center for Engineering Structure Disaster Prevention and Control, Guangzhou University) Deng, Ting (Guangzhou University-Tamkang University Joint Research Center for Engineering Structure Disaster Prevention and Control, Guangzhou University) |
1 | Belouchrani, A., Abed-Meraim, K., Cardoso, J.F. and Moulines, E. (1997), "A blind source separation technique using second order statistics", IEEE Trans. Signal Process., 45(2), 434-444. https://doi.org/10.1109/78.554307. DOI |
2 | Cole, H.A. (1973), "On-line failure detection and damping measurement of aerospace structures by random decrement signatures", NASA., CR-2205. |
3 | Li, Q.S. and Wu, J.R. (2007), "Time-frequency analysis of typhoon effects on a 79-storey tall building", J. Wind Eng. Ind. Aerod., 95(12), 1648-1666. https://doi.org/10.1016/j.jweia.2007.02.030. DOI |
4 | Li, Q.S., Xiao, Y.Q., Wong, C.K. and Jeary, A.P. (2004), "Field measurements of typhoon effects on a super tall building. Engineering Structures", Eng. Struct., 26(2), 233-244. https://doi.org/10.1016/j.engstruct.2003.09.013. DOI |
5 | Fu, J.Y., Wu, J.R., Xu A., Li, Q.S. and Xiao, Y.Q. (2012), "Full-scale measurements of wind effects on Guangzhou West Tower", Eng. Struct., 35, 120-139. https://doi.org/10.1016/j.engstruct.2011.10.022. DOI |
6 | He, Y.H., Li, Q.S., Zhu H.P., Han, X.L., He, Y.C. and Li, X. (2018), "Monitoring of structural modal parameters and dynamic responses of a 600m-high skyscraper during a typhoon", Struct. Des. Tall Spec. Build., 27(6), e1456. https://doi.org/10.1002/tal.1456. DOI |
7 | Li, Q.S. and Yi, J. (2016), "Monitoring of dynamic behaviour of super-tall buildings during typhoons", Struct Infrastruct. E., 12(3), 289-311. https://doi.org/10.1080/15732479.2015.1010223. DOI |
8 | Li, Q.S., Xiao, Y.Q. and Wong, C.K. (2005), "Full-scale monitoring of typhoon effects on super tall buildings", J. Fluids Struct., 20(5), 697-717. https://doi.org/10.1016/j.jfluidstructs.2005.04.003. DOI |
9 | Li, Q.S., Xiao, Y.Q., Wu, J.R., Fu, J.Y. and Li, Z.N. (2008), "Typhoon effects on super-tall buildings", J. Sound Vib., 313(3-5), 581-602. https://doi.org/10.1016/j.jsv.2007.11.059. DOI |
10 | Pan, H.R. and Xie, Z.N. (2016), "Modified Bayesian spectral density approach and its application to modal parameter identification of super-tall building", J. Build. Struct., 37(12), 27-32. DOI: 10.14006/j.jzjgxb.2016.12.004. DOI |
11 | Tamura, Y. and Suganuma, S. (1996), "Evaluation of amplitude-dependent damping and modal frequency of buildings during strong winds", J. Wind Eng. Ind. Aerod., 59(2-3), 115-130. https://doi.org/10.1016/0167-6105(96)00003-7. DOI |
12 | Tamura, Y., Shimada, K. and Hibi, K. (1993), "Wind response of a tower (Typhoon observation at the Nagasaki Huis Ten Bosch Domtoren)", J. Wind Eng. Ind. Aerod., 50, 309-318. https://doi.org/10.1016/0167-6105(93)90086-4. DOI |
13 | Xu, A., Xie, Z.N., Gu, M. and Wu, J.R. (2015), "Amplitude dependency of damping of tall structures by random decrement technique", Wind Struct., 21(2), 159-182. DOI:10.12989/was.2015.21.2.159. DOI |
14 | Yi, J. and Li, Q.S. (2015), "Wind tunnel and full-scale study of wind effects on a super-tall building", J. Fluids Struct., 58, 236-253. https://doi.org/10.1016/j.jfluidstructs.2015.08.005. DOI |
15 | Zhou, K. and Li, Q.S. (2021), "Effects of time-variant modal frequencies of high-rise buildings on damping estimation", Earthq. Eng Struct. Dyn., 50(2), 394-414. https://doi.org/10.1002/eqe.3336. DOI |
16 | Fu, J.Y., Li, Q.S., Wu, J.R., Xiao, Y.Q. and Song, L.L. (2008), "Field measurements of boundary layer wind characteristics and wind-induced responses of super-tall buildings", J. Wind Eng. Ind. Aerod., 96(8-9), 1332-1358. https://doi.org/10.1016/j.jweia.2008.03.004. DOI |
17 | Zhang, L.L., Hu, X.Q., Xie, Z.N., Shi, B.Q., Zhang, L. and Wang, R.H. (2020), "Field measurement study on time-varying characteristics of modal parameters of super high-rise buildings during super typhoon", J. Wind Eng. Ind. Aerod., 200, 104139. https://doi.org/10.1016/j.jweia.2020.104139. DOI |
18 | Xie, Z.N., Liu, C.L. and Yu, X.F. (2020), "Field measurements and wind tunnel experimental investigations of wind effects on Guangzhou West Tower", Struct. Des. Tall Spec. Build., 29(13), e1774. https://doi.org/10.1002/tal.1774. DOI |
19 | Yi, J., Zhang, J.W. and Li, Q.S. (2013), "Dynamic properties and wind-induced responses of a super-tall building during typhoons", J. Wind Eng. Ind. Aerod., 121, 116-130. https://doi.org/10.1016/j.jweia.2013.08.006. DOI |
20 | Pan, H.R., Xie, Z.N., Xu, A. and Zhang, L. (2017), "Wind effects on Shenzhen Zhuoyue Century Center: Field measurement and wind tunnel test", Struct. Des. Tall Spec. Build., 26(13), e1376. https://doi.org/10.1002/tal.1376. DOI |
![]() |