Browse > Article
http://dx.doi.org/10.12989/sem.2022.82.5.651

Assessment of seismic demand and damping of a reinforced concrete building after CFRP jacketing of columns  

Inci, Pinar (Department of Civil Engineering, Istanbul Kultur University)
Goksu, Caglar (Faculty of Civil Engineering, Istanbul Technical University)
Tore, Erkan (Department of Civil Engineering, Balikesir University)
Binbir, Ergun (Faculty of Civil Engineering, Istanbul Technical University)
Ates, Ali Osman (Department of Civil Engineering, Faculty of Technology, Gazi University)
Ilki, Alper (Faculty of Civil Engineering, Istanbul Technical University)
Publication Information
Structural Engineering and Mechanics / v.82, no.5, 2022 , pp. 651-665 More about this Journal
Abstract
While the lateral confinement provided by an FRP jacket to a concrete column is passive in nature, confinement is activated when the concrete expands due to additional compression stresses or significant shear deformations. This characteristic of FRP jacketing theoretically leads to similar initial stiffness properties of FRP retrofitted buildings as the buildings without retrofit. In the current study, to validate this theoretical assumption, the initial stiffness characteristics, and thus, the potential seismic demands were investigated through forced vibration tests on two identical full-scale substandard reinforced concrete buildings with or without FRP retrofit. Power spectral density functions obtained using the acceleration response data captured through forced vibration tests were used to estimate the modal characteristics of these buildings. The test results clearly showed that the natural frequencies and the mode shapes of the buildings are quite similar. Since the seismic demand is controlled by the fundamental vibration modes, it is confirmed using vibration-based full-scale tests that the seismic demands of RC buildings remain unchanged after CFRP jacketing of columns. Furthermore, the damping characteristics were also found similar for both structures.
Keywords
CFRP; forced vibration test; reinforced concrete; retrofitting; seismic demand;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 Chopra, A.K. (2001), Dynamics of Structures: Theory and Application to Earthquake Engineering, 3rd Edition, Prentice Hall, Upper Saddle River.
2 Corradi, M., Borri, A., Castori, G. and Coventry, K (2015), "Experimental analysis of dynamic effects of FRP reinforced masonry vaults", Mater., 8(12), 8059-8071. https://doi.org/10.3390/ma8125445.   DOI
3 Ewins, D.J. (1984), Modal Testing: Theory and Practice, Vol. 15, Letchworth, Research Studies Press.
4 Fardis, M.N. and Khalili HH (1982), "FRP-encased concrete as a structural material", Mag. Concrete Res., 34, 191-202. https://doi.org/10.1680/macr.1982.34.121.191.   DOI
5 Ghatte, H.F., Comert, M., Demir, C. and Ilki, A. (2016), "Evaluation of FRP confinement models for substandard rectangular RC columns based on full-scale reversed cyclic lateral loading tests in strong and weak directions", Polym. (Basel), 8, 1-24. https://doi.org/10.3390/polym8090323.   DOI
6 Ilki, A. and Kumbasar, N. (2002), "Behavior of damaged and undamaged concrete strengthened by carbon fiber composite sheets", Struct. Eng. Mech., 13(1), 75-90. https://doi.org/10.12989/sem.2002.13.1.075.   DOI
7 Ilki, A., Kumbasar, N. and Koc, V. (2004), "Low strength concrete members externally confined with FRP sheets", Struct. Eng. Mech., 18(2), 167-194. https://doi.org/10.12989/sem.2004.18.2.167.   DOI
8 Ilki, A., Tore, E., Demir, C. and Comert, M. (2018), "Code based performance prediction for a full-scale FRP retrofitted building test", Seismic Hazard Risk Assess., 467-477. https://doi.org/10.1007/978-3-319-74724-8_31.   DOI
9 Lam, L. and Teng, J.G. (2003), "Design-oriented stress-strain model for FRP-confined concrete", Constr. Build. Mater., 17(6-7), 471-489. https://doi.org/10.1016/S0950-0618(03)00045-X.   DOI
10 Marthong, C. (2019), "Rehabilitation and strengthening of exterior RC beam column connections using epoxy resin injection and FRP sheet wrapping: Experimental study", Struct. Eng. Mech., 72(6), 723-736. https://doi.org/10.12989/sem.2019.72.6.723.   DOI
11 TS-500 (2000), Requirements for Design and Construction of Reinforced Concrete Structures, Turkish Standards Institute, Ankara. (in Turkish)
12 Turkish Seismic Design Code (TSDC) (2007), Regulations for Buildings to be Constructed in Earthquake Prone Areas, Ankara, Turkey.
13 Wang, Z., Wang, D., Smith, S.T. and Lu, D. (2012), "Experimental testing and analytical modeling of CFRP-confined large circular RC columns subjected to cyclic axial compression", Eng. Struct., 40, 64-74. https://doi.org/10.1016/j.engstruct.2012.01.004.   DOI
14 Welch, P. (1967), "The use of fast Fourier transform for the estimation of power spectra: a method based on time averaging over short, modified periodograms", IEEE Tran. Audio Electroacoust., 15(2), 70-73. https://doi.org/10.1109/TAU.1967.1161901.   DOI
15 Lin, G., Zeng, J.J., Teng, J.G. and Li, L.J. (2020), "Behavior of large-scale FRP-confined rectangular RC columns under eccentric compression", Eng. Struct., 216, 110759. https://doi.org/10.1016/j.engstruct.2020.110759.   DOI
16 Russo, S. (2013), "On the monitoring of historic Anime Sante church damaged by earthquake in L'Aquila", Struct. Control Hlth. Monit., 20(9), 1226-1239. https://doi.org/10.1002/stc.1531.   DOI
17 Saadatmanesh, H., Ehsani, M.R. and Jin L. (1996). Seismic strengthening of circular bridge pier models with fiber composites", ACI Struct. J., 93, 639-647.
18 Singh, B., Chidambaram, R.S., Sharma, S. and Kwatra, N. (2017), "Behavior of FRP strengthened RC brick in-filled frames subjected to cyclic loading", Struct. Eng. Mech., 64(5), 557-566. https://doi.org/10.12989/sem.2017.64.5.557.   DOI
19 TEC (1975), Specification for Structures to be Built in Disaster Areas, Turkish Ministry of Public Works and Settlement, Ankara. (in Turkish)
20 Tore, E., Demir, C., Comert, M. and Ilki, A. (2021), "Seismic collapse performance of a full-scale concrete building with lightly reinforced columns", J. Struct. Eng., 147(12), 04021207. https://doi.org/10.1061/(ASCE)ST.1943-541X.0003178.   DOI
21 Baghiee, N., Esfahani, M.R. and Moslem, K. (2009), "Studies on damage and FRP strengthening of reinforced concrete beams by vibration monitoring", Eng. Struct., 31(4), 875-893. https://doi.org/10.1016/j.engstruct.2008.12.009.   DOI
22 Wu, Y.F. and Jiang, C. (2013), "Effect of load eccentricity on the stress-strain relationship of FRP-confined concrete columns", Compos. Struct., 98, 228-241. https://doi.org/10.1016/j.compstruct.2012.11.023.   DOI
23 Ozbakkaloglu, T., Lim, J.C. and Vincent, T. (2013), "FRP-confined concrete in circular sections: Review and assessment of stress-strain models", Eng. Struct., 49, 1068-1088. https://doi.org/10.1016/j.engstruct.2012.06.010.   DOI
24 PEER, Pasific Earthquake Research Center. https://peer.berkeley.edu/.
25 Qiu, Q. and Lau, D. (2018), "Defect detection in FRP-bonded structural system via phase-based motion magnification technique", Struct. Control Hlth. Monit., 25(12), e2259. https://doi.org/10.1002/stc.2259.   DOI
26 Michel, C., Karbassi, A. and Lestuzzi, P. (2018), "Evaluation of the seismic retrofitting of an unreinforced masonry building using numerical modeling and ambient vibration measurements", Eng. Struct., 158, 124-135. https://doi.org/10.1016/j.engstruct.2017.12.016.   DOI
27 Altunisik, A.C., Karahasan, O.S., Genc, A.F., Okur, F.Y., Gunaydin, M., Kalkan, E. and Adanur, S. (2018b), "Effect of fiber-reinforced polymer strengthening on dynamic characteristics of reinforced concrete frame using model updating", ACI Struct. J., 115, 1589-1601.   DOI
28 ASCE41-17 (2017), Seismic Evaluation and Retrofit of Existing Buildings, ASCE/SEI 41-17, Reston, VA.
29 Bonfiglioli, B., Pascale, G. and Martinez de Mingo, S. (2004), "Dynamic testing of reinforced concrete beams damaged and repaired with CFRP sheets", J. Mater. Civil Eng., ASCE, 16(5), 400-406. https://doi.org/10.1061/(ASCE)0899-1561(2004)16:5(400).   DOI
30 Bai, Y.L., Dai, J.G., Mohammadi, M., Lin, G. and Mei, S.J. (2019), "Stiffness-based design-oriented compressive stressstrain model for large-rupture-strain (LRS) FRP-confined concrete", Compos. Struct., 223, 110953. https://doi.org/10.1016/j.compstruct.2019.110953.   DOI
31 Bournas, D.A. and Triantafillou, T.C. (2011), "Bar buckling in RC columns confined with composite materials", J. Compos. Constr., 15, 393-403. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000180.   DOI
32 Catbas, F.N., Aktan, A.E., Allemang, R.J. and Brown, D.L. (1998), "A correlation function for spatial locations of scaled mode shapes-(COMEF)", Society for Experimental Mechanics, Inc, 16th International Modal Analysis Conference, 2, 1550-1555.
33 Catbas, F.N., Grimmelsman, K.A., Ciloglu, S.K., Burgos-Gil, I. and Coll-Borgo, M. (2006), "Static and dynamic testing of a concrete T-beam bridge before and after carbon fiber reinforced polymers (CFRP) retrofit", J. Transp. Res. Board, 1976(1), 76-87. https://doi.org/10.1177/0361198106197600109.   DOI
34 Ye, L., Yue, Q., Zhao, S. and Li, Q. (2002), "Shear strength of reinforced concrete columns strengthened with carbon-fiber-reinforced plastic sheet", J. Struct. Eng., 128, 1527-1534. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:12(1527).   DOI
35 Ilki, A., Comert, M., Demir, C., Orakcal, K., Ulugtekin, D., Tapan, M. and Kumbasar, N. (2014), "Performance based rapid seismic assessment method (PERA) for reinforced concrete frame buildings", Adv. Struct. Eng., 17(3), 439-459. https://doi.org/10.1260/1369-4332.17.3.439.   DOI
36 Barros, J.A.O., Dias, S.J.E. and Lima, J.L.T. (2007), "Efficacy of CFRP-based techniques for the flexural and shear strengthening of concrete beams", Cement Concrete Compos., 29, 203-217. https://doi.org/10.1016/j.cemconcomp.2006.09.001.   DOI
37 AFAD, Disaster and Emergency Management Presidency, https://tadas.afad.gov.tr/map.
38 Abdessemed, M., Kenai, S., Bali, A. and Kibboua, A. (2011), "Dynamic analysis of a bridge repaired by CFRP: Experimental and numerical modelling", Constr. Build. Mater., 25(3), 1270-1276. https://doi.org/10.1016/j.conbuildmat.2010.09.025.   DOI
39 Del Zoppo, M., Di Ludovico, M., Balsamo, A. and Prota, A. (2018), "Comparative analysis of existing RC columns jacketed with CFRP or FRCC", Polym., 10(4), 361. https://doi.org/10.3390/polym10040361.   DOI
40 Fenerci, A., Binici, B., Ezzatfar, P., Canbay, E. and Ozcebe, G. (2016), "The effect of infill walls on the seismic behavior of boundary columns in RC frames", Earthq. Struct., 10(3), 539-562. https://doi.org/10.12989/eas.2016.10.3.539.   DOI
41 Inci, P., Goksu, C., Tore, E. and Ilki, A. (2021), "Effects of seismic damage and retrofitting on a full-scale substandard RC building-ambient vibration tests", J. Earthq. Eng., 1-28. https://doi.org/10.1080/13632469.2021.1887009.   DOI
42 Mander, J.B., Priestley, M.J. and Park, R. (1988), "Theoretical stress-strain model for confined concrete", J. Struct. Eng., 114(8), 1804-1826. https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1804).   DOI
43 Oggu, P., Gopikrishna, K. and Nagariya, A. (2021), "Seismic behavior and response reduction factors for concrete moment-resisting frames", Bull. Earthq. Eng., 19, 5643-5663. https://doi.org/10.1007/s10518-021-01184-z.   DOI
44 Altunisik, A.C., Karahasan, O.S., Genc, A.F., Okur, F.Y., Gunaydin, M., Kalkan, E. and Adanur, S. (2018a), "Modal parameter identification of RC frame under undamaged, damaged, repaired and strengthened conditions", Measure., 124, 260-276. https://doi.org/10.1016/j.measurement.2018.04.037.   DOI