Browse > Article
http://dx.doi.org/10.12989/sem.2021.79.1.117

Application of a newly puzzle shaped crestbond rib shear connector in composite beam using inverted T steel girder: An experimental study  

Dao, Duy Kien (Department of Civil Engineering, Ho Chi Minh City University of Technology and Education)
Kim, In-Tae (School of Urban, Architecture and Civil Engineering, Pusan National University)
Phan, Haidang (Institute of Theoretical and Applied Research, Duy Tan University)
Publication Information
Structural Engineering and Mechanics / v.79, no.1, 2021 , pp. 117-129 More about this Journal
Abstract
The shear connector is the most important part of a composite beam and promotes a composite action between a steel beam and concrete slab. This paper presents the experiment results of three large-scale composite beams with a newly puzzle shaped crestbond rib shear connector. The behavior of this shear connector was investigated and the results were correlated with those obtained from the push-out-test specimens. Four-point-bending load testing was carried out on steel-concrete composite beam models to consider the effects of the concrete strength, number of transverse rebars in the crestbond and the width of the concrete slab. The results of large scale experimental test include of: the deflection, ultimate load, strains of the concrete, steel beam and Perfobond connectors; the relative slip between the steel beam and the concrete slab at the end of the beams; and the relative failure mechanism. The results showed that the general behavior of a steel-concrete composite beam using Perfobond shear connectors was similar to that of a steel-concrete composite beam using conventional shear connectors such as head stud shear connector. The newly puzzle shaped crestbond shear connectors showed satisfactory performance and could be considered for application in composite structures.
Keywords
composite behavior; crestbond rib shear connector; loading test; opposite steel beam; shear resistance formula;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Kim, S.H., Choi, K.T., Park, S.J., Park, S.M. and Jung, C.Y. (2013), "Experiment shear resistance evaluation of Y-type perfobond rib shear connector", J. Constr. Steel Res., 82, 1-18. https://doi.org/10.1016/j.jcsr.2012.12.001.   DOI
2 Hamed, A., Mehdi, D., Morteza, H.A.B., Bahram, N.N. and Ebrahim, R. (2014), "Mechanical behavior of steel-concrete composite decks with perfobond shear connectors", Steel Compos. Struct., 17(3), 339-358. https://doi.org/10.12989/scs.2014.17.3.339.   DOI
3 Jianan, Q., Jingquan, W., Ming, L. and LeileI, C. (2017), "Shear capacity of stud shear connectors with initial damage: Experiment, FEM model and theoretical formulation", Steel Compos. Struct., 25(1), 79-92. https://doi.org/10.12989/scs.2017.25.1.079.   DOI
4 Lorenc, W., Kubica, E. and Kozuch, M. (2010), "Testing procedures in evaluation of resistance of innovative shear connection with composite dowels", Arch. Civil Mech. Eng., 10, 51-63. https://doi.org/10.1016/S1644-9665(12)60136-8.   DOI
5 Ollgaard, J., Slutter, R. and Fisher, J. (1971), "Shear strength of stud connectors in lightweight and normal-weight concrete", AISC Eng. J., 8(2), 55-64.
6 Rodrigues, J.P.C. and Laim, L. (2014), "Experimental investigation on the structural response of T, T-block and T-Perfobond shear connectors at elevated temperatures", Eng. Struct., 75(0), 299-314. https://doi.org/10.1016/j.engstruct.2014.06.016.   DOI
7 Preco+ (2016), Prefabricated Enduring Composite Beams based on innovative Shear Transmission; RFCS RFS2-CT-2011-00026, Research Fund for Coal and Steel (RFCS) of the European Community, EU.
8 Rovnak, M., Duricova, A. and Ivanco, V. (2000), "Non-traditional shear connections in steel-concrete composite structures", Compos. Hybrid Struct., 1(2), 305-312.
9 Pilate. M., Bongani, S. and Hans, B. (2012), "Modelling and integrity assessment of shear connectors in precast cast-in-situ concrete bridges", Struct. Eng. Mech., 42(1), 55-72. https://doi.org/10.12989/sem.2012.42.1.055.   DOI
10 PreCo-Beam (2009), "Prefabricated enduring composite beams based on innovative shear transmission", Final Report, Research Fund for Coal and Steel, Contract No. RFSR-CT-2006-00030. 01/07/2006-30/06/2009.
11 Shim, C.S., Lee, P.G., Kim, D.W. and Chung, C.H. (2011), "Effects of group arrangement on the ultimate strength of stud shear connection", Compos. Constr. Steel Concrete, 6, 92-101. https://doi.org/10.1061/41142(396)8.   DOI
12 He, Y.L., Wu, X.D., Xiang, Y.Q., Wang, Y.H., Liu, L.S. and He, Z.H. (2017), "Mechanical behavior of stud shear connectors embedded in HFRC", Steel Compos. Struct., 24(2), 177-189. https://doi.org/10.12989/scs.2017.24.2.177.   DOI
13 Kim, S.H., Lee, C.G., Davaadorj, A., Yoon, J.H. and Won, J.H. (2010), "Experimental evaluation of joints consisting of parallel perfobond ribs in steel-PSC hybrid beams", Int. J. Steel Struct., 10, 373-384. https://doi.org/10.1007/BF03215845.   DOI
14 Thien, P.D., Kien, D.D., Van Khoa, N. and Hung, N.T. (2020), "Application of element combine39 to reflect the nature of newly puzzel shaped crestbond rib shear connector in composite beam", 2020 5th International Conference on Green Technology and Sustainable Development (GTSD), 317-320.
15 Kim, S.H., Park, S.J., Heo, W.H. and Jung, C.Y. (2015), "Shear resistance characteristic and ductility of Y-type perfobond rib shear connector", Steel Compos. Struct., 18(2), 497-517. https://doi.org/10.12989/scs.2015.18.2.497.   DOI
16 Lee, Y.H., Kim, M.S., Kim, H. and Kim, D.J. (2014), "Shear resistance of stud connectors in high strength concrete", Struct. Eng. Mech., 52(4), 647-661. https://doi.org/10.12989/sem.2014.52.4.647.   DOI
17 Hosaka, T., Mitsuki, K., Hiragi, H., Ushijima, Y., Tachibana, Y. and Watanabe. H. (2000), "An experimental study on shear characteristics of perfobond strip and it's rational strength equation", J. Struct. Eng., 46(3), 1593-1604.
18 Jorge, B., Luciano M.B., Enrique, M. and Bruno, M. (2018), "Review of stud shear resistance prediction in steel-concrete composite beams", Steel Compos. Struct., 27(3), 355-370. https://doi.org/10.12989/scs.2018.27.3.355.   DOI
19 Dao, D.K., Chu, T.H.V., Bui, D.V. and Le, V.P.N. (2018). "Application of a newly puzzel shaped crestbond rib shear connector in composite beam using opposite T steel girder: An experimental study", The 4th Conference Congres International de Geotechnique Ouvrages Structures CIGOS-2017.
20 Lorenc, W., Kozuch, M. and Rowinski, S. (2014a), "The behaviour of puzzle-shaped composite dowels-Part I: Experimental study", J. Constr. Steel Res., 101, 482-499. https://doi.org/10.1016/j.jcsr.2014.05.013.   DOI
21 Lorenc, W., Kozuch, M. and Rowinski, S. (2014b), "The behaviour of puzzle-shaped composite dowels-Part II: Theoretical investigations", J. Constr. Steel Res., 101, 482-499. https://doi.org/10.1016/j.jcsr.2014.05.012.   DOI
22 Kim, S.H., Heo, W.H., Woo, K.S., Jung, C.Y. and Park, S.J. (2014b), "End bearing resistance of Y-type perfobond rib according to rib width-height ratio", J. Constr. Steel Res., 103, 101-116. https://doi.org/10.1016/j.jcsr.2014.08.003.   DOI
23 Le, V.P.N., Bui, D.V., Chu, T.H.V., Kim, I.T., Ahn, J.H. and Dao, D.K. (2016), "Behavior of steel and concrete composite beams with a newly puzzle shape of crestbond rib shear connector: An experimental study", Struct. Eng. Mech., 60(6), 1001-1019. https://doi.org/10.12989/sem.2016.60.6.1001.   DOI
24 Vianna, J.d.C., Costa-Neves, L.F., Vellasco, P.C.G.d.S. and de Andrade, S.A.L. (2009), "Experimental assessment of Perfobond and T-Perfobond shear connectors structural response", J. Constr. Steel Res., 65, 408-421. https://doi.org/10.1016/j.jcsr.2008.02.011.   DOI
25 Mirza, O. and Kaewunruen, S. (2018), "Influence of shear bolt connections on modular precast steel-concrete composites for track support structures", Steel Compos. Struct., 27(5), 647-659. https://doi.org/10.12989/scs.2018.27.5.647.   DOI
26 Sal, R. and Ferreira, D. (2007), "Semi-rigid composite frames with perfobond and T-rib connectors Part 1: Full scale tests", J. Constr. Steel Res., 63(2), 263-279. https://doi.org/10.1016/j.jcsr.2006.04.011.   DOI
27 Shuangjie. Z., Chen, Z. and Yuqing, L. (2018), "Experimental shear strength evaluation of perfobond shear connector with various hole shapes", Struct. Eng. Mech., 67(2), 131-142. https://doi.org/10.12989/sem.2018.67.2.131.   DOI
28 Leonhardt, F., Andra, H.P. and Neues, H.W. (1987), "New improved shear connector with high fatigue strength for composite structures", Beron-und Stahlbetonbau Heft., 12, 325-331.   DOI
29 Kim, S.H., Choi, J., Park, S.J., Ahn, J.H. and Jung, C.Y. (2014a), "Behavior of composite girder with Y-type perfobond rib shear connector", J. Constr. Steel Res., 103, 275-289. https://doi.org/10.1016/j.jcsr.2014.09.012.   DOI
30 Vianna, J.d.C., Costa-Neves, L.F., Vellasco, P.C.G.d.S. and de Andrade, S.A.L. (2008), "Structural behaviour of T-Perfobond shear connectors in composite girders: An experimental approach", Eng. Struct., 30(9), 2381-2391. https://doi.org/10.1016/j.engstruct.2008.01.015.   DOI
31 Kim, K.S, Han, O., Gombosuren, M. and Kim, S.H. (2019), "Numerical simulation of Y-type perfobond rib shear connectors using finite element analysis", Steel Compos. Struct., 31(1), 53-67. https://doi.org/10.12989/scs.2019.31.1.053.   DOI
32 Kim, S.H., Kim, K.S., Park, S., Ahn, J.H. and Lee, M.K. (2016), "Y-type perfobond rib shear connectors subjected to fatigue loading on highway bridges", J. Constr. Steel Res., 122, 445-454. https://doi.org/10.1016/j.jcsr.2016.04.015.   DOI
33 Chu, T.H.V., Bui, D.V., Le, V.P.N, Kim, I.T., Anh, J.H. and Dao, D.K. (2016), "Shear resistancebehaviors of anewly puzzle shape of crestbond rib shear connector: an experimental study", Steel Compos. Struct., 21(5), 1157-1182. https://doi.org/10.12989/scs.2016.21.5.1157.   DOI
34 Xing, W., Lin, X. and Shiling, P. (2015), "Shear behavior of multi-hole perfobond connectors in steel-concrete structure", Struct. Eng. Mech., 56(6), 983-1001. https://doi.org/10.12989/sem.2015.56.6.983.   DOI
35 Chu, T.H.V., Le, V.P.N., Dao, D.K., Nguyen, T.H. and Bui, D.V. (2018). "Shear resistance behaviors of a newly puzzle shape of crestbond rib shear connector: an experimental study", The 4th conference Congres International de Geotechnique Ouvrages Structures CIGOS-2017.
36 Ahn, J.H., Lee, C.G. and Won, J.H. (2010), "Shear resistance of the perfobond rib shear connector depending on concrete strength and rib arrangement", J. Constr. Steel Res., 66, 1295-1307. https://doi.org/10.1016/j.jcsr.2010.04.008.   DOI
37 Bui, D.V. (2010), "Behaviour of Steel-Concrete Composite beams made of Ultra high performance concrete", Der Wirtschaftswissenschaftlichen Fakultater Universitat Leipzig, Leipzig, October.
38 Chromiak, P. and Studnicka, J. (2006), "Load capacity of perforated shear connector", J. Eng. Inform. Sci., 1(3), 23-30. https://doi.org/10.1556/Pollack.1.2006.3.2.
39 de Andrade, S. (2007), "Semi-rigid composite frames with perfobond and T-rib connectors Part 2: Design models assessment", J. Constr. Steel Res., 63(2), 280-292. https://doi.org/10.1016/j.jcsr.2006.04.010.   DOI