Browse > Article
http://dx.doi.org/10.12989/sem.2020.74.3.381

Behavior of CFS built-up battened columns: Parametric study and design recommendations  

Vijayanand, S (Department of Civil Engineering, Kongu Engineering College)
Anbarasu, M (Department of Civil Engineering, Government College of Engineering)
Publication Information
Structural Engineering and Mechanics / v.74, no.3, 2020 , pp. 381-394 More about this Journal
Abstract
The structural performance of cold-formed steel (CFS) built-up battened columns were numerically investigated in this paper. The built-up column sections were formed by connecting two-lipped channels back-to-back, with a regular spacing of battens plates, and have been investigated in the current study. Finite element models were validated with the test results reported by the authors in the companion paper. Using the validated models, the parametric study was extended, covering a wider range of overall slenderness to assess the accuracy of the current design rules in predicting the design strengths of the CFS built-up battened columns. The parameters viz., overall slenderness, different geometries, plate slenderness (b/t ratio) and yield stress were considered for this study. In total, a total of 228 finite element models were analyzed and the results obtained were compared with current design strength predicted by Effective Width Method of AISI Specifications (AISI S100:2016) and European specifications (EN1993-1-3:2006). The parametric study results indicated that the current design rules are limited in predicting the accuracy of the design strengths of CFS built-up battened columns. Therefore, a design equation was proposed for the AISI and EC3 specifications to predict the reliable design strength of the CFS Built-up battened columns and was also verified by the reliability analysis.
Keywords
cold-formed steel; effective width method; lipped channel; numerical study; battened column; reliability analysis; built-up columns;
Citations & Related Records
Times Cited By KSCI : 22  (Citation Analysis)
연도 인용수 순위
1 Maia, W., Vieira Jr, L., Schafer, B. and Malite, M. (2016), "Experimental and numerical investigation of CFS double angle members under compression", J. Construct. Steel Res., 121, 398-412. https://doi.org/10.1016/j.jcsr.2016.03.003.   DOI
2 Megnounif, A., Djafour, M., Belarbi, A. and Kerdal, D. (2008), "Strength buckling predictions of CFS built-up columns", Struct. Eng. Mech., 28(4), 443-460. https://doi.org/10.12989/sem.2008.28.4.443.   DOI
3 Muftah, F., Sani, M., Hisyam, M.S., Muda, M.F. and Mohammad, S. (2014), "Assessment of Connection Arrangement of Built-up CFS Section under Axial Compression", Adv. Mater. Res., https://doi.org/10.1002/cepa.224.
4 Muthuraj, H., Sekar, S., Mahendran, M. and Deepak, O. (2017), "Post buckling mechanics and strength of CFS columns exhibiting Local-Distortional interaction mode failure", Struct. Eng. Mech., 64(5), 621-640. https://doi.org/10.12989/sem.2017.64.5.621.   DOI
5 Roy, K., Ting, T.C.H., Lau, H.H. and Lim, J.B. (2018), "Nonlinear behavior of axially loaded back-to-back built-up CFS un-lipped channel sections", Steel Compos. Struct., 28(2), 233-250. https://doi.org/10.12989/scs.2018.28.2.233.   DOI
6 Sahoo, D.R. and Rai, D.C. (2007), "Built-up battened columns under lateral cyclic loading", Thin-Walled Struct., 45(5), 552-562. https://doi.org/10.1016/j.tws.2007.02.016.   DOI
7 Kherbouche, S. and Megnounif, A. (2019), "Numerical study and design of thin walled cold formed steel built-up open and closed section columns", Eng. Struct., 179, 670-682. https://doi.org/10.1016/j.engstruct.2018.10.069.   DOI
8 Saleh, A., Zahrai, S.M. and Mirghaderi, S.R. (2016), "Experimental study on innovative tubular web RBS connections in steel MRFs with typical shallow beams", Struct. Eng. Mech., 57(5), 785-808. https://doi.org/10.12989/sem.2016.57.5.785.   DOI
9 Schafer, B.W., and Pecoz, T. (1998), "Computational modelling of cold-formed steel: characterizing geometric imperfections and residual stresses", J. Construct. Steel Res., 47(3), 193-210. https://doi.org/10.1016/S0143-974X(98)00007-8.   DOI
10 Serror, M.H., Soliman, E.G. and Hassan, A.F. (2017), "Numerical study on the rotation capacity of CFRP strengthened cold formed steel beams", Steel Compos. Struct., 23(4), 385-397. https://doi.org/10.12989/scs.2017.23.4.385.   DOI
11 Shi, G., Liu, Z., Ban, H., Zhang, Y., Shi, Y. and Wang, Y. (2012), "Tests and finite element analysis on the local buckling of 420 MPa steel equal angle columns under axial compression", Steel Compos. Struct., 12(1), 31-51. https://doi.org/10.12989/scs.2011.12.1.031.   DOI
12 Standards of Australia (2018), CFS Structures, AS/NZS 4600.
13 ValsaIpe, T., SharadaBai, H., ManjulaVani, K. and Iqbal, M.M.Z. (2013), "Flexural behavior of CFS concrete composite beams", Steel Compos. Struct., 14(2), 105-120. https://doi.org/10.12989/scs.2013.14.2.105.   DOI
14 Vijayanand, S. and Anbarasu, M. (2019), "Strength and behavior of cold-formed steel built-up battened columns: tests and numerical validation", J. Struct. Eng. (Madras), 46(2), 154-164.
15 Whittle, J. and Ramseyer, C. (2009), "Buckling capacities of axially loaded, cold-formed, built-up C-channels", Thin Wall. Struct.,47(2), 190-201. https://doi.org/10.1016/j.tws.2008.05.014.   DOI
16 Young, B. and Chen, J. (2008), "Design of CFS built-up closed sections with intermediate stiffeners", J. Struct. Eng., 134(5), 727-737. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:5(727).   DOI
17 ABAQUS (2014), ABAQUS Standard (Version 6.14.2), Simulia Inc., Johnston, RI, U.S.A.
18 Zhang, J.H. and Young, B. (2015), "Numerical investigation and design of cold-formed steel built-up open section columns with longitudinal stiffeners", Thin Wall. Struct., 89, 178-191. https://doi.org/10.1016/j.tws.2014.12.011.   DOI
19 Zhang, J.H. and Young, B. (2018), "Finite element analysis and design of CFS built-up closed section columns with web stiffeners", Thin-wall. Struct., 131, 223-237. https://doi.org/10.1016/j.tws.2018.06.008.   DOI
20 Zhou, W. and Jiang, L. (2017), "Distortional buckling of cold-formed lipped channel columns subjected to axial compression", Steel Compos. Struct., 23(3), 331-338. https://doi.org/10.12989/scs.2017.23.3.331.   DOI
21 Anbarasu, M., Kumar, S.B. and Sukumar, S. (2013), "Study on the effect of ties in the intermediate length cold formed steel (CFS) columns", Struct. Eng. Mech., 46(3), 323-335. https://doi.org/10.12989/sem.2013.46.3.323.   DOI
22 AISI (2007), North American specification for the design of cold formed steel structural members, Washington, DC, U.S.A.
23 AISI (2016), North American specification for the design of cold formed steel structural members, Washington, DC, U.S.A.
24 Anbarasu, M. (2019a), "Simulation of flexural behaviour and design of CFS closed built-up beams composed of two sigma sections for local buckling", Eng. Struct., 191, 549-562. https://doi.org/10.1016/j.engstruct.2019.04.093.   DOI
25 Anbarasu, M. and Sukumar, S. (2014), "Influence of spacers on ultimate strength of intermediate length thin walled columns", Steel Compos. Struct., 16(4), 437-454. https://doi.org/10.12989/scs.2014.16.4.437.   DOI
26 Anbarasu, M. and Venkatesan, M. (2019b), "Behaviour of CFS built-up I-section columns composed of four U-profiles", Adv. Struct. Eng., 22(3), 613-625. https://doi.org/10.1177/1369433218795568.   DOI
27 Anbarasu, M. and Dar, M. (2020), "Improved design procedure for battened cold-formed steel built-up columns composed of lipped angles", J. Construct. Steel Res., 164, 105781. https://doi.org/10.1016/j.jcsr.2019.105781.   DOI
28 AS1170.1-2002, Standards Association of Australia, Sydney, Australia.
29 ASCE (2006), Minimum design loads for buildings and other structures, ASCE/SEI7-05. American Society of Civil Engineers Standard; 2006., China, October.
30 Dar, M.A., Subramanian N., Dar A.R., Majid M., Haseeb M., Tahoor M., (2019b) "Structural efficiency of various strengthening schemes for cold-formed steel beams: Effect of global imperfections", Steel Compos. Struct., 30(4), 393-403.   DOI
31 Devi, S.V. and Singh, K.D. (2020), "Finite element study of lean duplex stainless steel semi-elliptical hollow section members with circular perforation subjected to torsion", Thin Wall. Struct., 146 https://doi.org/10.1016/j.tws.2019.106464.
32 El Aghoury, M., Salem, A., Hanna, M. and Amoush, E. (2013), "Ultimate capacity of battened columns composed of four equal slender angles", Thin Wall. Struct., 63, 175-185.https://doi.org/10.1016/j.tws.2012.07.019.   DOI
33 Eurocode 3 (2006), Design of steels tructures-Part1-5: Plated structural elements, BS EN 1993-1-5, London.
34 El Aghoury, M., Salem, A., Hanna, M. and Amoush, E. (2015), "Strength of cold formed battened columns subjected to eccentric axial compressive force", J. Construct. Steel Res., 113, 58-70. https://doi.org/10.1016/j.jcsr.2015.04.008.   DOI
35 Eurocode 3 (2005), Design of steel structures-Part1-1: General rules and rules for building, BS EN 1993-1-1, London.
36 Eurocode 3 (2006), Design of steel structures-Part 1-3: General rules supplementary rules for cold-formed members and sheeting, BS EN 1993-1-3, Brussels.
37 Ghannam, M. (2017), "Axial load capacity of CFS built-up stub columns", J. Steel Struct., 17(4), 1273-1283. https://doi.org/10.1007/s13296-017-1202-0.   DOI
38 Gunalan, S. and Mahendran, M. (2013), "Improved design rules for fixed ended CFS columns subject to flexural-torsional buckling", Thin Wall. Struct., 73, 1-17. https://doi.org/10.1016/j.tws.2013.06.013.   DOI
39 Bandula Heva, Y. and Mahendran, M. (2012), "Flexural-torsional buckling tests of CFS compression members at elevated temperatures", Steel Compos. Struct., 14(3), 205-227. https://doi.org/10.12989/scs.2013.14.3.205.   DOI
40 Australian Standard, SAA Loading Code, Part1: Dead and Live Loads and Load Combinations.
41 Biggs, K.A., Ramseyer, C., Ree, S. and Kang, T.H.K. (2015), "Experimental testing of cold-formed built-up members in pure compression", Steel Compos. Struct., 18(6), 1331-1351. https://doi.org/10.12989/scs.2015.18.6.1331.   DOI
42 Dabaon, M., Ellobody, E. and Ramzy, K. (2015), "Experimental investigation of built-up CFS section battened columns", Thin-Walled Structures, 92, 137-145. https://doi.org/10.1016/j.tws.2015.03.001.   DOI
43 Dar, M., Subramanian, N., Dar, A. and Raju, J. (2015a), "Experimental investigations on the structural behaviour of a distressed bridge", Struct. Eng. Mech., 56(4), 695-705. https://doi.org/10.12989/sem.2015.56.4.695.   DOI
44 Dar, M., Yusuf, M., Dar, A. and Raju, J. (2015b), "Experimental study on innovative sections for cold formed steel beams", Steel Compos. Struct., 19(6), 1599-1610. https://doi.org/10.12989/scs.2015.19.6.1599.   DOI
45 Dar, M. A., Subramanian N., Dar A. R., Anbarasu M., Lim J.B.P., (2018a), "Structural Performance of Cold-formed Steel Composite Beams", Steel Compos. Struct., 27(5), 545-554.   DOI
46 Dar, M.A., Sahoo, D.R., Pulikkal, S. and Jain, A.K. (2018b), "Behaviour of laced built-up CFS columns: Experimental investigation and numerical validation", Thin Wall. Struct., 132, 398-409. https://doi.org/10.1016/j.tws.2018.09.012.   DOI
47 Dar, M., Subramanian, N., Rather, A.I., Dar, A., Lim JBP, Anbarasu M. and Roy, K. (2019a), "Effect of angle stiffeners on the flexural strength and stiffness of cold-formed steel beams", Steel Compos. Struct., 33(2), 225-243.   DOI
48 Lu, Y., Li, W., Zhou, T. and Wu, H. (2017), "Novel local buckling formulae for cold-formed C-section columns considering end condition effect", Thin Wall. Struct., 116, 265-276. https://doi.org/10.1016/j.tws.2017.02.034.   DOI
49 Kripka, M. and Chamberlain Pravia, Z.M. (2013), "CFS channel columns optimization with simulated annealing method", Struct. Eng. Mech., 48(3), 383-394. https://doi.org/10.12989/sem.2013.48.3.383.   DOI