Equivalent static wind loads analysis of tall television towers considering terrain factors of hilltops based on force measurement experiment |
Ke, Shitang
(College of Aerospace Engineering, Nanjing University of Aeronautics and Astronautics)
Wang, Hao (College of Aerospace Engineering, Nanjing University of Aeronautics and Astronautics) Ge, Yaojun (State Key Laboratory for Disaster Reduction in Civil Engineering, Tongji University) Zhao, Lin (State Key Laboratory for Disaster Reduction in Civil Engineering, Tongji University) Cao, Shuyang (State Key Laboratory for Disaster Reduction in Civil Engineering, Tongji University) |
1 | American Standards (2010), "Minimum Design Loads for Buildings and Other Structures", ASCE 7-10, Structural Engineering Institute |
2 | Belloli, M., Rosa, L. and Zasso, A. (2014), "Wind loads on a high slender tower: Numerical and experimental comparison", Eng. Struct., 68(4), 24-32. DOI |
3 | Breuer, P., Chmielewski, T., Gorski, P., Konopka, E. and Tarczynski, L. (2008), "The Stuttgart TV Tower-displacement of the top caused by the effects of sun and wind", Eng. Struct., 30(10), 2771-2781. DOI |
4 | Carril, C.F., Isyumov, N. and Brasil, R.M.L.R.F. (2003), "Experimental study of the wind forces on rectangular latticed communication towers with antennas", J. Wind Eng. Indust. Aerodyn., 91(8), 1007-1022. DOI |
5 | Chinese Standards (2012), "Lode Code for The Design of Building Structures", GB50009-2012, China Building Industry Press. (in Chinese) |
6 | Feng, M.Q. and Zhang, R. (1997), "Wind-induced vibration characteristics of Nanjing TV tower", Int. J. Nonlin. Mech., 32(4), 693-706. DOI |
7 | Glanville, M.J. and Kwok, K.C.S. (1995), "Dynamic characteristics and wind induced response of a steel frame tower", J. Wind Eng. Indust. Aerodyn., 54-55(2), 133-149. DOI |
8 | Japanese Standards (2004), "AIJ Recommendations for Loads on Buildings", AIJ 2004, Research Committee on Structures. (in Japanese). |
9 | Kareem, A. and Kabat, S., Jr F.L.H. (1997), "Aerodynamics of Nanjing Tower: a case study", J. Wind Eng. Indust. Aerodyn., 77-78(5), 725-739. |
10 | Ke, S.T. and Wang, H. (2016), "Analysis on equivalent static wind loads of large television tower considering topographic effect", J. Southeast Univ. Nat. Sci. Ed., 46(3), 545-551. (in Chinese) |
11 | Ke, S.T., Ge, Y.J., Zhao, L. and Tamura, Y. (2012), "A new methodology for analysis of equivalent static wind loads on super-large cooling towers", J. Wind Eng. Indust. Aerodyn., 111(111), 30-39. DOI |
12 | Ke, S.T., Wang, T.G., Ge, Y.J. and Tamura, Y. (2014), "Windinduced responses and equivalent static wind loads of towerblade coupled large wind turbine system", Struct. Eng. Mech., 52(3), 485-505 DOI |
13 | Kitagawa, T., Wakahara, T., Fujino, Y. and Kimura, K. (1997), "An experimental study on vortex-induced vibration of a circular cylinder tower at a high wind speed", J. Wind Eng. Indust. Aerodyn., 69(3), 731-744. |
14 | Li, B., Yang, Q. and Yang, J. (2016), "Wind characteristics near ground in south-eastern coast area of China based on field measurement", Geomat. Nat. Hazard. Risk, 3(4), 1-13. |
15 | Li, Z.L, Wei, Q.K., Huang, H.J. and Sun, Y. (2011), "Windinduced response of super tall building in hilly terrain", J. Vib. Shock, 30(5), 43-48. |
16 | Pirner, M. and Fischer, O. (1999), "Long-time observation of wind and temperature effects on TV towers", J. Wind Eng. Indust. Aerodyn., 79(1), 1-9 DOI |
17 | Simiu, E. and Scanlan, R.H. (1978), Wind Effects on Structures: an Introduction to Wind Engineering, Wiley |
18 | Yang, F., Dang, H. and Niu, H. (2016), "Wind tunnel tests on wind loads acting on an angled steel triangular transmission tower", J. Wind Eng. Indust. Aerodyn., 156(156), 93-103. DOI |
19 | Zhang, Z.Q., Li, A.Q. and Can, D.Y. (2016), "Simulation of dynamic wind load on Heifei Television Tower", J. Southeast Univ. Nat. Sci. Ed., 31(1), 69-73. (in Chinese) |
20 | Zhou, X., Huang, P. and Gu, M. (2010), "Wind loads and windinduced responses of guangzhou new TV tower", Adv. Struct. Eng., 13(4), 707-726. DOI |
![]() |