Abstract
The use of steel-concrete composite members has been significantly increased as they have the advantages of the reduction of cross sectional areas, excellent ductility against earthquake loadings and a longer life span than typical steel frame members. The increased use of composite members requires an intensive study on the shear resistance evaluation of stud connectors in high strength concrete. However, the applicability of currently available standards is limited to composite members with normal and lightweight strength concrete. In this paper, push-out tests were performed on 24 specimens to investigate the structural behavior and shear resistance of stud connectors in high strength concrete. Test parameters include the existence of shear studs, height to diameter ratio of a shear stud, its diameter and concrete cover thickness. A shear resistance equation of stud connectors is proposed through a linear regression analysis based on the test results. Its accuracy is compared with those of existing shear resistance equations for studs in normal and lightweight concrete.
Keywords
shear stud; composite members; shear resistance; high strength concrete; steel pipe;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 An, L. and Cederwall, K. (1996), "Push-out tests on studs in high strength and normal strength concrete", J. Constr. Steel Res., 36(1), 15-29.   DOI   ScienceOn
2 Cheong, H.Y., Kim, S.S. and Kim, K.S. (2000), "The shear strength of headed stud connector in embedded steel column bases", J. Architect. Ins. Kor, 16(1), 89-96.
3 Chithira, K. and Baskar, K. (2014), "Experimental Study on circular concrete filled steel tubes with and without shear Connectors", Steel Compos. Struct., 16(1), 99-116.
4 Deric, J.O. (1990), "Deterioration in strength of stud connectors in composite bridge beams", J. Struct. Eng., ASCE, 116(12), 3417-3431.   DOI
5 Hiragi, H., Matsui, S., and Fukumoto, Y. (1989), "Derivation strength equations of headed stud shear connectors-static strength", Struct. Eng., 35(3), 1221-1232.
6 Kang, J.W., Park, S.M. and Kim, Y.T. (2005), "An analytic study on the bond stress between concrete and steel tube in CFT tublar column", J. Kor. Assoc. Spat. Struct., 5(3), 101-107.   과학기술학회마을
7 Oehlers, D.J. and Johnson, R.P. (1987), "The strength of stud shear connections in composite beams", Struct. Eng., 65B(2), 44-48.
8 Ollgaard, J.G., Slutter, R.G. and Fisher, J.W. (1971), "Shear strength of stud connectors in lightweight and normal-weight concrete", AISC Eng. J., 8(2), 55-64.
9 Prakash, A., Anandavalli, N., Madheswaran, C.K. and Lakshmanan, N. (2012), "Experimental investigation on flexural behaviour of HSS Stud connected steel-concrete composite girders", Steel Compos. Struct., 13(3), 239-258.   DOI   ScienceOn
10 Seok, K.Y., Ju, G.S., Choi, J.Y., Chae, S.H. and Kang, J.W. (2007), "A study on improved analytic method for the bond stress between concrete and steel tube in CFT column", J. Kor. Assoc. Spat. Struct., 7(2), 83-90.   과학기술학회마을
11 Shim, C.S., Kim, H.H., Han, J.H. and Lee, P.G. (2006), "Evaluation of ultimate strength of shear connection in steel embedded composite girders", J. Kor. Soc. Steel Constr., 18(4), 405-415.
12 Valente, I. and Cruz, P.J.S. (2009), "Experimental analysis of shear connection between steel and lightweight concrete", J. Constr. Steel Res., 65(10-11), 1954-1963.   DOI   ScienceOn
13 Vianna, J.C., Costa-Neves, L.F., Vellasco, P.C.G.S. and Andrade, S.A.L. (2008), "Structural behaviour of TPerfobond shear connectors in composite girders: An experimental approach", Eng. Struct., 30(9), 2381-2391.   DOI   ScienceOn
14 Commission of European Communities (1985), Eurocode No.4: Common Unified Rules for Composite Steel and Concrete Structure, Luxembourg.
15 Kennedy, S.J. (1984), "End connection effects on the strength of concrete filled HSS beam columns", University of Alberta, M.Sc. Thesis, Department of Civil Engineering, Edmonton, Alberta, Canada.
16 Architectural Institute of Korea (2009), Korean Building Code - Structural 2009, Ministry of Construction and Transportation of Korea, Seoul, Korea.
17 Canadian Standards Association (CSA) (2003), S16-01 Limit States Design of Steel Structure, Canadian Standards Association, Toronto.
18 GB 50010-2002 (2002), Code for Design of Concrete Structures, Chinese Standard, Beijing.
19 KS F 2405 (2005), Method of Test for Compressive Strength of Concrete, Korea Standards Association. (In Korean)
20 American Institute of Steel Construction (AISC) (2004), Manual of Steel Construction-Load and Resistance Factor Design, American Institute of Steel Construction, Chicago.