Browse > Article
http://dx.doi.org/10.12989/sem.2005.19.6.721

Experimental analysis of a semi-actively controlled steel building  

Occhiuzzi, Antonio (Department of Structural Analysis and Design, School of Engineering, University of Napoli Federico II)
Spizzuoco, Mariacristina (Department of Structural Analysis and Design, School of Engineering, University of Napoli Federico II)
Publication Information
Structural Engineering and Mechanics / v.19, no.6, 2005 , pp. 721-747 More about this Journal
Abstract
The strong need of verifying theories formulated for semi-active control through applications to real structures is due to the fact that theoretical research on semi-active control systems is not matched by a corresponding satisfactory experimental activity. This paper shows how a smart system including magnetorheological devices as damping elements can be implemented in a large-scale structural model, by describing in detail the kind of electronics (dedicated hardware and software) adopted during the experimental campaign. It also describes the most interesting results in terms of reduction of the seismic response (either experimental or numerical) of the semi-actively controlled structure compared to a passive operating control system, and in terms of the evaluation criteria proposed in the benchmark for seismically excited controlled buildings. The paper also explains how to derive from the classical theory of optimal control the adopted control logic, based on a clear physical approach, and provides an exhaustive picture of the time delays characterizing the control sequence.
Keywords
semi-active control; magnetorheological dampers; large scale tests;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
Times Cited By Web Of Science : 3  (Related Records In Web of Science)
Times Cited By SCOPUS : 4
연도 인용수 순위
1 Yang, N.J. and Akbarpour, A. (1987), 'New optimal control algorithms for structural control', J. Eng. Mech., 113, 1369-1386   DOI   ScienceOn
2 Chen, Z.Q., Wang, X.Y., Ko, J.M., Ni, Y.Q., Spencer, B.F., Yang, G. and Hu, J.H. (2004), 'MR damping system for mitigating wind-rain induced vibration on Dongting Lake Cable-Stayed Bridge', Wind and Structures, 7(5), 293-304   DOI   ScienceOn
3 Chu, S.Y., Soong, T.T., Reinhorn, A.M., Helgeson, R.J. and Riley, M.A. (2002), 'Integration issues in implementation of structural control systems', J. Struct. Control, 9, 31-58   DOI   ScienceOn
4 De Luca, A. and Serino, G. (1988), 'Lapproccio energetico nella progettazione sismica', Ingegneria Sismica, Anno, V(3), 18-27 (in Italian)
5 Hiwatashi, T., Shiozaki, Y., Fujitani, H., Iiba, M., Tomura, T., Sodeyarna, H. and Soda, S. (2002), 'Semi-active control of large-scale test frame by magneto-rheological damper', Proc. 3rd World Conf. on Structural Control, ed F Casciati, United Kingdom: Wiley, 2, 355-360
6 Inaudi, J.A. and Hayen, J.C (1995), 'Research on variable-structure systems in the United States', Proc. Post-SMiRT Conf. Sem. on Seismic Isolation, Passive Energy Dissipation and Control of Vibrations, Santiago, Cile: GLIS, 591-622
7 Inaudi, J.A. (2000), 'Performance of variable-damping systems: Theoretical analysis and simulation', Proc. 3rd Int. Workshop on Structural Control, ed F Casciati & Magonette, United Kingdom: World Scientific, 301-316
8 Jung, H.J., Spencer, B.F., Ni, Y.Q. and Lee, I.W. (2004), 'State-of-the-art of semiactive control systems using MR fluid dampers in civil engineering applications', Struct. Eng. Mech., 17(3), 493-526   DOI   ScienceOn
9 Kobori, T. (2002), 'Past, present and future in seismic response control of civil engineering structures', Proc. 3rd World Conf. on Structural Control, ed F Casciati, United Kingdom: Wiley, 1, 9-14
10 Luenberger, D.G. (1979), Introduction to Dynamic Systems - Theory, Models & Applications, John Wiley & Sons Inc., USA
11 Medeot, R., Braun, C., Seiler, C., Debost, S., Hedin, F., Bergamo, G., Forni, M., Bettinali, F., Serino, G. and Fuller, K.N.G. (2001), 'The EC-funded project SPACE (Semi-Active and Passive Control of the Dynamic Behavior of Structures Subjected to Earthquakes, Wind and Vibrations)', Proc. 7th Int. Seminar on Seismic Isolation, Passive Energy Dissipation and Active Control of Vibrations of Structures, Assisi, Italy: GLIS, 1, 447-475
12 Morishian, S., Shiraishi, T. and Nakaya, N. (2002), 'Adaptive vibration control of a structure using MR damper', Proc. 3rd World Conf. on Structural Control, ed F Casciati, United Kingdom: Wiley, 3, 761-766
13 National Instruments (2000), LabVIEW$^{TM}$ - User Manual, National Instruments Corp., Austin, Texas - USA
14 Nishitani, A. and Inoue, Y. (2001), 'Overview of the application of active/semiactive control to building structures in Japan', Earth. Eng. Struct. Dyn., 30, 1565-1574   DOI   ScienceOn
15 Occhiuzzi, A. and Serino, G. (2002), 'Control strategies for semi-active structural control devices', Proc. 3rd World Conf. on Structural Control, ed F Casciati, United Kingdom: Wiley, 3, 641-647
16 Occhiuzzi, A. and Spizzuoco, M. (2003), 'Semi-active magnetorheological dampers applied to a steel building', Proc. Forth Int. Conf. on Behaviour ofSteel Structures in Seismic Areas, ed F M Mazzolani, The Netherlands: Balkema, 633-639
17 Symans, M.D. and Constantinou, M.C. (1999), 'Semi-active control systems for seismic protection of structures: A state-of-the-art review', Eng. Struct., 21, 469-487   DOI   ScienceOn
18 Occhiuzzi, A., Spizzuoco, M. and Serino, G. (2003), 'Experimental analysis of magnetorheological dampers for structural control', Smart Mater. Struct., 12, 703-711   DOI   ScienceOn
19 Serino, G., Occhiuzzi, A., Spizzuoco, M., Seiler, C. and Fischer, O. (2002), 'Semi-active control via MR dampers: Algorithms, numerical modeling and prediction of the resulting response of structures', Proc. 3rd World Conf. on Structural Control, ed F Casciati, United Kingdom: Wiley, 2, 1113-1118
20 Spencer, B.F. and Nagarajaiah, S. (2003), 'State of the art of structural control', J. Struct. Engrg., 129, 845-856   DOI   ScienceOn
21 Tagami, J., Koshida, H., Kurino, H., Sugiyama, T., Suwa, M. and Mori, F. (2002), 'Forced vibration test of an 11-storey building with semi-active switching oil damper', Proc. 3rd World Conf. on Structural Control, ed F Casciati, United Kingdom: Wiley, 2, 75-80
22 University of Illinois Urbana-Champaign - Department of Civil and Environmental Engineering http://cee.uiuc.edu/sstl/benchmarks
23 Wongprasert, N. and Symans, M.D. (2002), 'Experimental evaluation of a smart base-isolation system consisting of spherical sliding bearings and variable fluid dampers', Proc. 3rd World Conf. on Structural Control, ed F Casciati, United Kingdom: Wiley, 2, 331-336
24 Yamamoto, M., Higashino, M. and Aizawa, S. (2002), 'Development of semi-active mass damper system using oil damper with solenoid valves', Proc. 3rd World Conf. on Structural Control, ed F Casciati, United Kingdom: Wiley, 2, 343-348
25 Yang, G., Spencer, B.F., Carlson, J.D. and Sain, M.K. (2002), 'Large-scale MR fluid dampers: Modeling and dynamic performance considerations', Eng. Struct., 24, 309-323   DOI   ScienceOn
26 Yang, N.J., Li, Z. and Liu, S.C. (1992), 'Stable controllers for istantaneous optimal control', J. Eng. Mech., 118, 1612-1630   DOI