Browse > Article
http://dx.doi.org/10.12989/sem.2004.17.5.627

Short-term cyclic performance of metal-plate-connected wood truss joints  

Gupta, Rakesh (Department of Wood Science and Engineering, 114 Richardson Hall, Oregon State University)
Miller, Thomas H. (Department of Civil, Construction, and Environmental Engineering, Oregon State University)
Freilinger, Shawn M. Wicks (Oregon Department of Transportation)
Publication Information
Structural Engineering and Mechanics / v.17, no.5, 2004 , pp. 627-639 More about this Journal
Abstract
The objective of this research was to evaluate the performance of metal-plate-connected truss joints subjected to cyclic loading conditions that simulated seismic events in the lives of the joints. We also investigated the duration of load factor for these joints. We tested tension splice joints and heel joints from a standard 9.2-m Fink truss constructed from $38-{\times}89-mm$ Douglas-fir lumber: 10 tension splice joints for static condition and for each of 6 cyclic loading conditions (70 joints total) and 10 heel joints for static condition and for each of 3 cyclic loading conditions (40 joints total). We evaluated results by comparing the strengths of the control group (static) with those of the cyclic loading groups. None of the cyclic loading conditions showed any strength degradation; however, there was significant stiffness degradation for both types of joint. The results of this research show that the current duration of load factor of 1.6 for earthquake loading is adequate for these joints.
Keywords
wood engineering; wood connections; duration of load; seismic loads; tension splice joint; heel joint; fink truss;
Citations & Related Records

Times Cited By Web Of Science : 0  (Related Records In Web of Science)
Times Cited By SCOPUS : 0
연도 인용수 순위
  • Reference
1 ASTM. (2000a), "Standard test methods for specific gravity of wood and wood-based materials", ASTM D2395, Annual Book of ASTM Standards, ASTM, West Conshohocken, PA.
2 National Design Specification for Wood Construction. (1997), Revised Edition. American Forest and PaperAssociation, Washington, DC.
3 Gupta, R., Vatovec, M. and Miller, T.H. (1996), "Metal-plate-connected wood joints: a literature review", ForestResearch Laboratory, Research Contribution 13, Oregon State University, Corvallis, OR.
4 TPI 1-1995. (1995), "National design standard for metal plate connected wood truss construction", Truss PlateInstitute, Madison, WI.
5 Gupta, R. and Gebremedhin, K.G. (1990), "Destructive testing of metal-plate-connected wood truss joints", J.Struct. Engrg., 116(7), 1971-1982.   DOI
6 Freilinger, S.M.W. (1998), "Short-term duration of load and cyclic performance of metal-plate-connected trussjoints", MS thesis, Civil Engineering and Forest Products, Oregon State University, Corvallis, OR.
7 Redlinger, M.J. (1998), "Behavior of metal-plate-connected wood truss joints under wind and impact loads", MSthesis, Oregon State University, Corvallis, OR.
8 ASTM. (2000b), "Standard test methods for direct moisture content measurement of wood and wood-basematerials", ASTM D4442. Annual Book of ASTM Standards, ASTM, West Conshohocken, PA.
9 Dolan, J.D. (1989), "The dynamic response of timber shear walls", Ph.D. thesis, Dept. of Civil Engineering,University of British Columbia, Vancouver, BC, Canada.
10 Dolan, J.D., Gutshall, S.T. and McLain, T.E. (1996), "Monotonic and cyclic tests to determine short-term loadduration performance of nail and bolt connections", Research Report No. TE-1994-001. Virginia PolytechnicInstitute and State University, Blacksburg, VA.
11 Emerson, R. and Fridley, K.J. (1996), "Cyclic loading of truss plate connections", For. Prod. J., 46(5), 83-90.
12 Kent, S.M., Gupta, R. and Miller, T.H. (1997), "Dynamic behavior of metal-plate-connected wood truss joints",J. Struct. Engrg., 123(8), 1037-1045.   DOI   ScienceOn