Browse > Article
http://dx.doi.org/10.12989/sem.2002.14.6.649

Reinforced concrete beam-column joints with lap splices under cyclic loading  

Karabinis, Athanasios I. (Department of Civil Engineering, Democritus University of Thrace)
Publication Information
Structural Engineering and Mechanics / v.14, no.6, 2002 , pp. 649-660 More about this Journal
Abstract
Experimental results are presented from tests conducted on reinforced concrete beam-column joints with lap splices under reversed cyclic loading simulating earthquake action. Response curves are compared for twenty-four specimens designed according to Eurocode 2. The main parameters of the investigation are, the geometry of the reinforcing bar extension, the applied axial load (normalized), the available cover over lap splice region extended as length required from Eurocode 2, as well as the shape and the volumetric percentage of the stirrups confining the lap splice zone. The results are evaluated with regards to the load intensity, the energy absorption capacity and the characteristics of the load deflection curve.
Keywords
reinforced concrete; joints; beam-column connections; lap splices; bond; cyclic load; Eurocode 2;
Citations & Related Records

Times Cited By Web Of Science : 0  (Related Records In Web of Science)
Times Cited By SCOPUS : 0
연도 인용수 순위
  • Reference
1 Lukose, K., Gergely, P. and White, R. (1982), "Behavior of reinforced concrete lapped splices for inelastic cyclicloading", ACI Struct. J., 79(5), March-April 1982, 355-365.
2 Paulay, T. and Priestley, M.J.N. (1992), "Seismic design of reinforced concrete and masonry buildings", J.Willey.
3 ACI Committee 318, "Building code requirements for structural concrete (ACI 318-95)", American Concrete Institute, Detroit 1995.
4 Rezansoff, T., Zacaruk, J. and Topping, R., (1988), "Tensile lap splices in reinforced concrete beams underinelastic cyclic loading", ACI Struct. J., January - February 1988, 46-52.
5 Karabinis, A. (1994), "Experimental investigation of the mechanical behavior of the lap splices", Proc. 11thGreek Concrete Conf., Vol. II, May, 50-68 (in Greek).
6 Canadian Standards Association. "Code for the design of concrete structures for buildings" (CAN3-A23.3M-84),Rexdale, 1984.
7 Paulay, T. (1982), "Lapped splices in earthquake resisting columns", ACI J., Nov. - Dec. 1982, 458-469.
8 'EC-8 - Eurocode 8 - Regulations for Design of Structures under Seismic Actions, Part 1-3, General Codes -Specific Codes for Various Construction Materials and Elements', ENV 1998-1-3-1994.
9 Sagan, V.E., Gergely, P. and White, R.N. (1991), "Behavior and design of non contact lap splices subjected torepeated inelastic tensile loading", ACI Struct. J., 88(4), July-August 1991, 420-431.
10 Karabinis, A. (1995), "Influence of shear on reinforced concrete beams with lap splices", 2nd East Asia-PacificConf. on Structural Engineering and Construction, Vol. 1, Goald Coast, Australia, July, 597-602.
11 'EC2 - Eurocode 2 - Design of Concrete Structures Part 1-1/1992', ENV 1992.
12 Panahshahi, N., White, R. and Gergely, P. (1992), "Reinforced concrete compression lap splices under inelasticcyclic loading", ACI Struct. J., 89(2), March-April 1992, 164-175.