A Tool Box to Evaluate the Phased Array Coil Performance Using Retrospective 3D Coil Modeling |
Perez, Marlon
(Department of Biomedical Engineering, Kyung Hee University)
Hernandez, Daniel (Department of Biomedical Engineering, Kyung Hee University) Michel, Eric (Department of Biomedical Engineering, Kyung Hee University) Cho, Min Hyoung (Department of Biomedical Engineering, Kyung Hee University) Lee, Soo Yeol (Department of Biomedical Engineering, Kyung Hee University) |
1 | Roemer PB, Edelstein WA, Hayes CE, Souza SP, Mueller OM. The NMR phased array. Magn Reson Med 1990;16:192-225 DOI |
2 | Lee RF, Giaquinto RO, Hardy CJ. Coupling and decoupling theory and its application to the MRI phased array. Magn Reson Med 2002;48:203-213 DOI |
3 | Keil B, Wald LL. Massively parallel MRI detector arrays. J Magn Reson 2013;229:75-89 DOI |
4 | Wong EY, Hillenbrand CM, Lewin JS, Duerk JL. Computer simulations for optimization of design parameters for intravascular imaging microcoil construction. Proc Intl Soc Mag Reson Med 2003;11:2386 |
5 | Constantinides C, Angeli S, Gkagkarellis S, Cofer G. Intercomparison of performance of RF coil geometries for high field mouse cardiac MRI. Concepts Magn Reson Part A. 2011;38A;236-252 |
6 | Hernandez D, Perez M, Lee SY. A bi-planar surface coil for parietal lobe imaging. Proc Intl Soc Mag Reson Med 2013;21:2793 |
7 | Kim DE, Park YM, Perez M, Hernandez D, Lee JH, Lee SY. Retrospective 3D modeling of RF coils using a 3D tracker for EM simulation. Concepts Magn Reson Part B 2013;43:126-132 DOI |
8 | Wiggins GC, Triantafyllou C, Potthast A, Reykowski A, Nittka M, Wald LL. 32-channel 3 tesla receive-only phased-array head coil with soccer-ball element geometry. Magn Reson Med 2006;56:216-223 DOI ScienceOn |
9 | Lattanzi R, Grant AK, Polimeni JR, et al. Performance evaluation of a 32-element head array with respect to the ultimate intrinsic SNR. NMR Biomed 2010;23:142-151 |
10 | Hoult DI. The principle of reciprocity in signal strength calculations- A mathematical guide. Concepts Magn Reson Part A 2000;12:173-187 DOI ScienceOn |
11 | Hartwig V, Tassano S, Mattii A, et al. Computational analysis of a radiofrequency knee coil for low-field MRI using FDTD. Applied Magn Reson 2013;44:389-400 DOI |
12 | Darrasse L, Kassab G. Quick measurement of NMR-coil sensitivity with a dual-loop probe. Review Scientific Instruments 1993;64:1841-1844 DOI |
13 | SEMCAD X MRI. Web site. http://www.speag.com/. |
14 | Griswold MA, Jakob PM, Nittka M, Goldfarb JW, Haase A. Partially parallel imaging with localized sensitivities (PILS). Magn Reson Med 2000;44:602-609 DOI ScienceOn |
15 | Seiberlich N, Griswold M. Parallel imaging in angiography. Magnetic Resonance Angiography. Springer, 2012:188 |