Exposure Assessments of Chemical Risk Factors to Airborne Contaminants in Foundry Process |
Bae, Hye-Jeong
(Institute for Industrial Health, Daegu Haany University)
Nam, Mi-Ran (Institute for Industrial Health, Daegu Haany University) Lee, Sang-Man (IESH-Solution CO. Ltd.) Jung, Yu-Jin (C.E.Tech Co. Ltd., R&D Center) Shon, Byung-Hyun (Dept. of Environmental Engineering, Hanseo University) Phee, Young-Gyu (Faculty of Health Science, Daegu Haany University) Jung, Jong-Hyeon (Faculty of Health Science, Daegu Haany University) |
1 | American Conference of Governmental Industrial Hygienists(ACGIH), 2001, Industrial Ventilation Manual of Recommended Practice, 24th Edition. |
2 | Alpaugh, E. L., 1988, Particulates in Fundamentals of Industrial Hygiene, 3rd ed, by Plog B. A., Chicago, Illinois, National Safety Council, 128. |
3 | Burgess, W., 1995, A Foundry Operation in Recognition of health hazards in industry, 2th ed, Wiley J & Sons, Canada, 106-139. |
4 | Chen, J., McLaughlin, J. K., Zhang, J. Y., Stone, B. J., Luo, J., Chen, R. A., Dosemeci, M., Rexing, S. H., Wu, Z., Hearl, F. J., McCawley, M. A., Blot, W. J., 1992, Mortality among Dust exposed Chinese Mine and Potter Workers, J. Occup. Med., 34(3):311-316. DOI |
5 | Cooper, T. C., Gressel, M. G., Froehlich, P. A., Caplan, P. E., Mickelsen, R. L., Valiante, D., Bost, P., 1993, Successful Reduction of Silica Exposure at Sanitary Ware Pottery, Am. Ind., Hyg. Assoc. j., 54(10) 600-606. DOI |
6 | Environmental Protection Agency(EPA), 1999, Compendium Method TO-11A: Determination of formaldehyde in ambient air using adsorbent cartridge followed by high performance liquid chromatography (HPLC). |
7 | Gomes, J., Lloyd, O. L., Norman, N. J., Pahwa, P., 2001, Dust exposure and impairment of lung function at a small iron foundry in a rapidly developing country, Occup Environ Med, 58, 656-662. DOI |
8 | Guenther, A., Hewitt, C. N., Erickson, D., Fall, R., Geron, C., Graedel, T., Harley, P., Klinger, L., Lerdau, M., McKay, W. A., Pierce, T., Scholes, B., Steinbrecher, R., Tallamraju, R., Taylor, J., Zimmerman, P., 1995, A global model of natural volatile organic compound emissions, Journal of Geophysical Research, 8873-8892. |
9 | Harley, R. A., Cass, G. R., 1995, Modeling the atmospheric concentrations of individual volatile organic compounds, Atmos. Environ, 29, 905-922. DOI |
10 | Jung, J. H., Lee, S. W., Lee, S. M., Shon, B. H., Lee, J. H., Jung, Y. J., 2013, Improvement of capturing velocity in the fume hood using Computational Fluid Dynamics(I) - uniform flow, The Korea Academia-Industrial Cooperation Society, 14(2), 9621-969. |
11 | Jung, Y. J., Park, K. W., Shon, B. H., Jung, J. H., 2013a, A numerical study on performance improvement of rnclosed hood in reverberatory furnace, Journal of the Korean Siciety of Urban Environment, 13(3), 235-242. |
12 | Jung, Y. J., Shon, B. H., Lee, S. M., Jung, J. H., 2013b, A Numerical Study on Performance Improvement of Canopy Hood in Melting Process, The Korea Academia-Industrial Cooperation Society, 14(3), 1519-1526. DOI |
13 | Kang, L. W., 2007, The New Casting Engineering, Bo Sung Gak Publishing company. |
14 | Park, H. S., 2007, Morphological Property and Size Distribution of Dust Particles Emitted from Iron Casting Processes, Environmental Societies Joint conference, 124. |
15 | Kim, M. R., Lee, K. R., Park, D. G., Jang, J. K., 2003, Phenol occurrence characteristics due to the use of chemical company in the casting process, Korea Solid Wastes Engineering Society, 11, 172-175. |
16 | Ministry of Employment and Labor(MoEL), 2012, Occupational exposure limits for chemical and physical agents, MoEL Notification No. 2012-31. |
17 | National Institute for Occupational Safety and Health (NIOSH), 2003, NIOSH manual of analytical methods : No 2016 [cited 2014 May 26]; Available at http://www.cdc.gov/niosh |
18 | Park, J. S., 2006, Development and Field Installation of a System of Simultaneously Removing Dust and Volatile Organic Compounds from Furan Process in Foundry, Korean Chem. Eng. Res., 44(2), 136-148. |
19 | Park, R. M., Ahn, Y. S., Stayner, L. T., Kang, S. K., Jang, J. K., 2005, Mortality of iron and steel workers in Korea, Am J Ind Med, 48:194-204. DOI |
20 | Perrault, G., Dion, C., Ostiguy, C., Michaud, D., Baril, M., 1992, Selective sampling and chemical speciation of airborne dust in ferrous foundries, Am Ind Hye Assoc J, 53(7):463-470. DOI |
21 | Phee, Y. G., Poh, Y. M., Lee, K. M., Kim, H. A., Kim, Y. W., Won, J. I., Kim, H. W., 1997, Analysis or quartz content and particle size distribution of airborne dust from selected foundry operations, Korean Ind. Hyg. Assoc. J, 7(2):196-208. |
22 | Sohn, J. Y., Yoon, D. W., 1995, Characteristics and Control of Volatile Organic Compounds in Indoor Air Environment, Korean Journal of Air-Conditioning and Refrigeration Engineering, 24(1), 44-55. |
23 | Zhang, M., Qi, C., Chen, W. H., Lu, Y., Du, X. Y., Li, W. J., Meng, C. S., 2010, Re-analysis of occupational hazards in foundry. Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi. Apr;28(4), 280-5. |
24 | World Health Organization(WHO), 2002, Europe exposure assessmentin studies on the chronic effectsoflong-term exposuretoairpollution. |