Browse > Article
http://dx.doi.org/10.5322/JES.2006.15.6.513

Biofiltration of Gaseous Toluene Using Activated Carbon Containing Polyurethane Foam Media  

Amarsanaa Altangerel (Department of Environmental Engineering, Kyungpook National University)
Shin Won-Sik (Department of Environmental Engineering, Kyungpook National University)
Choi Jeong-Hak (Environment Research Department, Research Institute of Industrial Science & Technology)
Choi Sang-June (Department of Environmental Engineering, Kyungpook National University)
Publication Information
Journal of Environmental Science International / v.15, no.6, 2006 , pp. 513-525 More about this Journal
Abstract
In recent decades, biofiltration has been widely accepted for the treatment of contaminated air stream containing low concentration of odorous compounds or volatile organic compounds (VOCs). In this study, conventional biofilters packed with flexible synthetic polyurethane (PU) foam carriers were operated to remove toluene from a contaminated air stream. PU foams containing various amounts of pulverized activated carbon (PAC) were synthesized for the biofilter media and tested for toluene removal. Four biofilter columns were operated for 60 days to remove gaseous toluene from a contaminated air stream. During the biofiltration experiment, inlet toluene concentration was in the range of 0-150 ppm and EBRT (i.e., empty bed residence time) was kept at 26-42 seconds. Pressure drop of the biofilter bed was less than 3 mm $H_2O/m$ filter bed. The maximum removal capacity of toluene in the biofilters packed with PU-PAC foam was in the order of column II (PAC=7.08%) > column III (PAC=8.97%) > column I (PAC=4.95%) > column IV (PAC=13.52%), while the complete removal capacity was in the order of column II > column I > column III > column IV. The better biofiltration performance in column II was attributed to higher porosity providing favorable conditions for microbial growth. The results of biodegradation kinetic analysis showed that PU-PAC foam with 7.08% of PAC content had higher maximum removal rate ($V_m$=14.99 g toluene/kg dry material/day) than the other PU-PAC foams. In overall, the performance of biofiltration might be affected by the structure and physicochemical properties of PU foam induced by PAC content.
Keywords
Biodegradation kinetics; Biofiltration; Powered activated carbon (PAC); Polyurethane foam; Toluene;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Moe, W. M. and R. L. Irvine, 2001, Effect of nitrogen limitation on performance of toluene degrading biofilters during transient loading, Wat. Res., 35, 1407-1414   DOI   ScienceOn
2 Delhomenie, M., L. Bibeau, N. Bredin, S. Roy, S. Broussau, R. Brzezinski, J. L. Kuge1mass and M. Heitz, 2002, Biofiltration of air contaminated with toluene on a compost-based bed, Adv. Environ. Res., 6, 239-254   DOI   ScienceOn
3 Abumaizar, R. J., W. Kocher and E. H. Smith, 1998, Biofiltration of BTEX contaminated air streams using compost-activated carbon filter media, J. Hazard. Mater., 60, 111-126   DOI   ScienceOn
4 Moe, W. M., R. L. Irvine and C. D. Montemagno, 1997, Preliminary investigation of polyurethane foam medium for use in vapor phase biofiltration, Proc. 199 CSCE-ASCE Env. Eng. Conf.: Protecting People and the Env., Edmonton, AB, Canada, S.J. Stanley and C.J.W. Ward (eds.), CSCE, Montreal, PQ, 1755-1766
5 Choi, J. H., Y. S. Jeong, Y. H. Kim, D. J. Joo, S. J. Choi, T. W. Ha, D. H. Lee and I. H. Park, 2003, Removal of ammonia by biofilters: A study with flow-modified system and kinetics, J. Air & Waste Manage. Assoc., 53, 92-101   DOI
6 Yani, M., M. Hirai and M. Shoda, 1998, Removal kinetics of ammonia by peat biofilter seeded with night soil sludge, J. Ferment. Bioeng., 85, 502-506   DOI   ScienceOn
7 Sorial, G. A., F. L. Smith, M. T. Suidan and P. Biswas, 1995, Evaluation of trickle bed biofilter media for toluene removal, J. Air & Waste Manage. Assoc., 45, 801-810   DOI
8 Holubar, P., C. Andorfer and R. Braun, 1995, Prevention of clogging in trickling filters for purification of hydrocarbon-contaminated waste air, Proc. of the 1995 Conference on Biofiltration, University of Southern California, D. S. Hodge and F. E. Reynolds, Jr., (eds.), 115-122
9 Severin, B. F., J. Shi, B. G. Cybul, L. M., Neilson and J. L. Furstenberg, 1995, High-rate low volume biofilters for industry, WEF: Industrial Wastes Technical Conference, Multimedia Pollution Control and Preventions, Pittsburgh, P A, USA, pp. 352
10 Moe, W. M. and R. L. Irvine, 2000, Polyurethane foam medium for biofiltration, Part I: Characterization, J. Env. Eng., 126, 815-825   DOI   ScienceOn
11 Lu, C., W. Chu and M. Lin, 2000, Removal of BTEX vapor from waste gases by a trickle bed biofilter, J. Air & Waste Manage. Assoc., 50, 411-417   DOI
12 Farmer, R. W., J. S. Chen, D. M. Kopchynski and W. J. Maier, 1995, Reactor switching: proposed biomass control strategy for the biofiltration process, In: Biological Unit Processes for Hazardous Waste Treatment, R. E. Hinchee, G. D. Sayles and R. S. Skeen (eds.), Battelle Press, 3, 243-248
13 Szycher, M., 1999, Szycher's Handbook of Polyurethanes, CRC Press, Boca Raton, FL, USA, 696pp
14 Devinny, J. S., M. A. Deshusses and T. S. Webster, 1999, Biofiltration for Air Pollution Control, CRC Press, Boca Raton, FL, USA, 299pp
15 Kim, N., M. Hirai and M. Shoda, 2000, Comparison of organic and inorganic packing materials in the removal of ammonia gas in biofilters, J. Hazard. Mater., 72, 77-90   DOI   ScienceOn
16 Liu, Y., Y. Sun, J. Chen, D. Xue and J. S. Chung, 2002, Simultaneous removal of ethyl acetate and toluene in air streams using compost-based biofilters, J. Hazard Mater., 95, 199-213   DOI   ScienceOn
17 Deshusses, M. A. and G. Hamer, 1993, The removal of volatile ketone mixtures from air in biofilters, Bioproc. Biosyst. Eng., 9, 141-146   DOI   ScienceOn
18 Martinez, F. A., 2001, Polyurethane Foam based Packing Media for Biofilters Removing Volatile Organic Compounds from Contaminated Air, M.S. Thesis, Louisiana State University, Baton Rouge, LA, USA, 84pp
19 Torkian, A., R. Dehghanzadeh and M. Hakimjavadi, 2003, Biodegradation of aromatic hydrocarbons in a compost biofilter, J. Chem. Technol. Biotechnol., 78, 795-801   DOI   ScienceOn
20 Moe, W. M. and R. L. Irvine, 2001, Polyurethane foam based biofilter media for toluene removal, Wat. Sci. Technol., 43(11), 35-42
21 Ergas, S. J., E. D. Schroeder and D. P. Chang, 1992, Biodegradation technology for volatile organic compound removal from air streams, Phase I: Performance verification, Prepared for Research Division, California Air Resources Board, Final Report Under Contract No. AO-32-137
22 Ergas, S. J., E. D. Schroeder, D. P. Y. Chang and R. L. Morton, 1995, Control of volatile organic compound emissions using a compost biofilter, Water Environ, Res., 67, 816-821   DOI
23 Moe, W. M. and R. L. Irvine, 2000, Polyurethane foam medium for biofiltration, Part II: Operation and Performance, J. Env. Eng., 126, 826-832   DOI   ScienceOn
24 Kinney, K. A., W. Wright, D. P. Chang and E. D. Schroeder, 1997, Biodegradation of vapor phase contaminants, In: Fundamentals and Applications of Bioremediation: Principles, I, S. K. Sikdar and R. L. Irvine (eds.), Technomic Publishing, Inc., Lancaster, PA, USA, pp.601-630