Browse > Article
http://dx.doi.org/10.3807/KJOP.2009.20.6.346

Measurement of Glucose and Protein in Urine Using Absorption Spectroscopy Under the Influence of Other Substances  

Yoon, Gil-Won (Department of Electronics & Information Engineering, Seoul National University of Technology)
Kim, Hye-Jeong (Institute for Biomedical Electronics, Seoul National University of Technology)
Publication Information
Korean Journal of Optics and Photonics / v.20, no.6, 2009 , pp. 346-353 More about this Journal
Abstract
Glucose and protein in urine are among the important substances for urine analysis and have generally been measured based on a reagent strip test. In this study, these two substances were measured using mid-infrared absorption spectroscopy. Samples were prepared from a commercial synthetic urine product. Glucose and albumin were added as well as red blood cells, which are expected to create the most spectroscopic interference of any substance. Concentrations of these substances were varied independently. Optimal wavelength regions were determined from a partial least squares regression analysis (glucose 980 - 1150/cm, albumin 1400 - 1570/cm). Interference by other substances increased the differences between measured and predicted values. Albumin measurement in particular weres heavily influenced by the presence of glucose and red blood cells. Depending on the inference by other substances, measurement errors were 29.85${\sim}$45.19 mg/dl for a glucose level between 0 and 1000 mg/dl and 14.0${\sim}$93.11 mg/dl for an albumin level of 0 ${\sim}$ 500 mg/dl. Our study proposes an alternative to the chemical test-strip analysis, which shows only discrete concentration levels.
Keywords
Urine; Absorption spectroscopy; Glucose; Albumin; Partial least squares regression;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 H. Kim and J. Lee, “Comparison of urine analyzer URISCAN S-300 Moditron M and Clinitek 100,” Inje Medical Journal 23, 713-719 (2002)
2 O. S. Khalil, “Spectroscopic and clinical aspects of noninvasive glucose measurements,” Clin. Chem. 45, 165-177 (1999)
3 http://www.clinic-clinic.com/clncl-mdcne/clnc-pthlgy/Introduction.htm
4 H. R. Park, B. K. Jeong, and N. W. Park, “Comparative evaluation of dipstick urinalysis by diostick readers,” Journal of Clinical Pathology and Quality Control 23, 239-246 (2001)
5 K. J. Jeon, S. Kim, K. K. Park, J.-W. Kim, and G. Yoon, “Non-invasive total hemoglobin measurement,” Journal of Biomedical Optics 7, 45-50 (2002)   DOI   ScienceOn
6 V. K. Bhutani, G. R. Gourley, S. Adler, B. Kreamer, C. Dalin, and L. H. Johnson, “Noninvasive measurement of total serum bilirubin in a multiracial predischarge newborn population to assess the risk of severe hyperbilirubinemia,” Pediatrics 106, 1-9 (2000)   DOI   ScienceOn
7 K. M. Ringsrud and J. J. Linne, Urinalysis and Body Fluids (Mosb-Year Book Inc., St. Louis, Missouri, USA, 1995), p. 27
8 H. Kim, I. Noh, and G. Yoon, “Glucose prediction in the interstitial fluid based on infrared absorption spectroscopy using multi-component analysis,” J. Opt. Soc. Korea 13, 279-285 (2009)   과학기술학회마을   DOI   ScienceOn
9 H. Chung, M. A. Arnold, M. Rhiel, and D. W. Murhammer, “Simultaneous measurements of glucose, glutamine, ammonia, lactate, and glutamate in aqueous solutions by near-infrared spectroscopy,” Applied Spectroscopy 50, 270-276 (1996)   DOI
10 H. M. Heise, R. Marbach, T. H. Koschinsky, and F. A. Gries, “Multicomponent assay for blood substrates in human plasma by mid-infrared spectroscopy and its evaluation for clinical analysis,” Applied Spectroscopy 48, 85-95 (1994)   DOI   ScienceOn
11 W. R. Premassiri, R. H. Clarke, and M. E. Womble, “Urine analysis by laser Raman spectroscopy,” Lasers Surg. Med. 28, 330-334 (2001)   DOI   ScienceOn
12 J. W. McMurdy and A. J. Berger, “Raman spectroscopybased creatinine measurement in urine samples from a multipatient population,” Applied Spectroscopy 57, 522-525 (2003)   DOI   ScienceOn
13 T. Tatara, Y. Iwao, J. Takeda, Y. Ishihara, S. Ohkochi, and H. Uedaira, “Proton nuclear magnetic resonance spectroscopy of urine for rapid multicomponent analysis of intraoperative cellular metabolites,” Clinica Chimica Acta. 279, 117-124 (1999)   DOI   ScienceOn
14 http://www.kmle.co.kr/viewDrug.php?inx=38763&c=8f7c6dfaee872256a677baf12855155e
15 J. L. Pezzaniti, T. W. Jeng, L. McDowell, and G. M. Oosta, “Preliminary investigation of near-infrared spectroscopic measurements of urea, creatinine, glucose, protein and ketone in urine,” Clinical Biochemistry 34, 239-246 (2001)   DOI   ScienceOn
16 R. A. Shaw, S. Kotowich, H. H. Mantsch, and M. Leroux, “Quantitation of protein, creatinine and urea in urine by near-infrared spectroscopy,” Clinical Biochemistry 29, 11-19 (1996)   DOI   ScienceOn
17 S. H. Park, Modern Design of Experiments (Minyongsa, Korea, 1995), pp. 11-21
18 Y. C. Shen, A. G. Davies, E. H. Linfield, P. F. Taday, D. D. Arnone, and T. S. Elsey, “Determination of glucose concentration in whole blood using Fourier-transform infraredspectroscopy,” Journal of Biological Physics 29, 129-133(2003)   DOI   ScienceOn
19 Y.-J. Kim and G. Yoon, “Multi component assay for human serum using mid-infrared transmission spectroscopy based on component-optimized spectral region selected by a first loading vector analysis in partial least square regression,” Applied Spectroscopy 56, 625-632 (2002)   DOI   ScienceOn