Browse > Article
http://dx.doi.org/10.5371/jkhs.2011.23.2.116

Ceramic on Ceramic Total Hip Arthroplasty - The Results of a Minimum 10-Years Follow up -  

Moon, Do-Hyun (Department of Orthopedic Surgery, Gil Medical Center, College of Medicine, Gachon University)
Choi, Jang-Seok (Department of Orthopedic Surgery, Gil Medical Center, College of Medicine, Gachon University)
Kim, Dong-Whan (Department of Orthopedic Surgery, Gil Medical Center, College of Medicine, Gachon University)
Kim, Kwang-Hee (Department of Orthopedic Surgery, Gil Medical Center, College of Medicine, Gachon University)
Publication Information
Hip & pelvis / v.23, no.2, 2011 , pp. 116-123 More about this Journal
Abstract
Purpose: We wanted to evaluate the clinical and radiographic results of ceramic on ceramic bearing cementless total hip arthroplasty with a minimum of 10-years follow up. Materials and Methods: This study was performed on 44 patients and 51 hips, and the patients were recruited among the patients who underwent ceramic-ceramic type cementless total hip arthroplasty from August 1998 to February 2000 and they were available for 10-years or longer follow up. The gender ratio was 28 males and 16 females, and the mean age at the time of surgery was 49 years (range: 26~77 years). Regarding the causality of disease, osteonecrosis was noted in 36 cases, degenerative arthritis was noted in 4 cases, acetabular dysplasia was noted in 4 cases and septic or tuberculous hip sequelae was noted in 7 cases. The clinical evaluation was performed according to the Harris hip score, and for the radiological evaluation of the femoral component, we assessed the degree of subsidence and the presence of periprosthetic osteolysis, endosteal new bone formation and cortical hypertrophy, and the final fixation state of the implant. In the cases with an acetabular cup osteoscleostic line in the vicinity of the acetabular cup, endosteal new bone formation, acetabular osteolysis and the vertical migration as well as the horizontal migration of the acetubular cup were assessed. Results: Regarding the clinical outcomes, the Harris hip score was improved from an average 59 points to 93 points at the final follow up. For the radiological results, osteolysis was not detected in the acetabular and femoral components, the subsidence of femoral stem was not beyond 2 mm on average and significant subsidence was not detected. In regard to complications, linear fracture during surgery was noted in 6 cases and postoperative hip dislocation was noted in 1 case. A ceramic head fracture occurred in one case and a ceramic liner fracture occurred in 2 cases. Conclusion: This type of articulation is a promising option at a minimum of 10-years follow up of 51 hips that underwent ceramic-ceramic bearing cementless total hip arthroplasty. However, our results demonstrated that surgeons should be aware of the potential risks of ceramic fracture when using ceramic-on-ceramic bearing surfaces. Additional longer-term follow-up is necessary.
Keywords
Total hip arthroplasty; Ceramic on ceramic bearing;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Willert HG, Semlitsch M. Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res. 1977;11:157-64.   DOI   ScienceOn
2 Sedel L. Evolution of alumina-on-alumina implants: a review. Clin Orthop Relat Res. 2000;379:48-54.
3 Nizard RS, Sedel L, Christel P, Meunier A, Soudry M, Witvoet J. Ten-year survivorship of cemented ceramicceramic total hip prosthesis. Clin Orthop Relat Res. 1992;282:53-63.
4 Yoon TR, Rowe SM, Jung ST, Seon KJ, Maloney WJ. Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces. J Bone Joint Surg Am. 1998;80:1459-68.
5 Han CD, Choi CJ, Yang IW, Lee DH. Total hip arthroplasty with ceramic-on-ceramic articulation - minimum 5-year follow-up results. J Korean Orthop Assoc. 2006;41:421-7.
6 Bizot P, Larrouy M, Witvoet J, Sedel L, Nizard R. Pressfit metal-backed alumina sockets: a minimum 5-year followup study. Clin Orthop Relat Res. 2000;379:134-42.
7 Garino JP. Modern ceramic-on-ceramic total hip systems in the United States: early results. Clin Orthop Relat Res. 2000;379:41-7.
8 Murphy SB. Ceramic-ceramic bearings in THA: the new gold standard--in the affirmative. Orthopedics. 2002;25:933-4.
9 Kim YM, Kim SR, Rhyu KH, Kim JK, Yoo JJ, Kim HJ. Short term results of ceramic-on-ceramic bearing Bicontact total hip arthroplasty. J Korean Hip Soc. 2001;13:1-7.
10 Lee SH, Kwon KD, Cho SH, Shin SJ, Youm YS. Ceramic on ceramic in cementless total hip arthroplasty: preliminary reports with minimal 3-year follow up. J Korean Hip Soc. 2003;15:124-30.
11 Yoo JJ ,Kim YM, Yoon KS, et al. Alumina-on-alumina THA in active patients younger than 40 years old-A 5-year minimum follow-up study. J Korean Orthop Assoc. 2006;41:404-12.
12 Bands R, Pelker RR, Shine J, Bradburn H, Margolis R, Leach J. The noncemented porous-coated hip prosthesis. A three-year clinical follow-up study and roentgenographic analysis. Clin Orthop Relat Res. 1991;269:209-19.
13 Gallo J, Stewart T, Novotny R, Dusza J, Galusek D. Early fracture of a plasma cup ceramic liner: a case report and surface analysis. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub. 2007;151:341-6.   DOI   ScienceOn
14 Lee YK, Yoo JJ, Koo KH, Yoon KS, Kim HJ. Metal neck and liner impingement in ceramic bearing total hip arthroplasty. J Orthop Res. 2011:29:218-22.   DOI   ScienceOn
15 Yang IH, Han CD, Lee JS. Cementless total hip arthroplasty using ceramic-on-ceramic oseonics system: minimum 8-year follow up results. J Korean Orthop Assoc. 2009;44:520-5.   DOI   ScienceOn
16 Callaghan JJ, Dysart SH, Savory CG. The uncemented porous-coated anatomic total hip prosthesis. Two-year results of a prospective consecutive series. J Bone Joint Surg Am. 1988;70:337-46.
17 Gruen TA, McNeice GM, Amstutz HC. "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17-27.
18 Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br. 1987;69:45-55.
19 DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20-32.
20 Mallory TH, Kraus TJ, Vaughn BK. Intraoperative femoral fractures associated with cementless total hip arthroplasty. Orthopedics. 1989;12:231-9.
21 Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990;72:518-28.
22 Boutin P. Total arthroplasty of the hip by fritted aluminum prosthesis. Experimental study and 1st clinical applications. Rev Chir Orthop Reparatrice Appar Mot. 1972;58:229-46.
23 Mittelmeier T, Walter A. The influence of prosthesis design on wear and loosening phenomena. CRC Crit Rev Biocompat. 1987;3:19.
24 Bierbaum BE, Nairus J, Kuesis D, Morrison JC, Ward D. Ceramic-on-ceramic bearings in total hip arthroplasty. Clin Orthop Relat Res. 2002;405:158-63.
25 Pfaff HG. Ceramic component failure and the role of proof testing. Clin Orthop Relat Res. 2000;379:29-33.
26 Clarke IC, Good V, Williams P, et al. Ultra-low wear rates for rigid-on-rigid bearing in total hip replacements. Proc Inst Mech Eng H. 2000;214:331-47.   DOI   ScienceOn
27 Sedel L, Kerboull L, Christel P, Meunier A, Witvoet J. Alumina-on-alumina hip replacement. Results and survivorship in young patients. J Bone Joint Surg Br. 1990;72:658-63.
28 Lee YK, Ha YC, Yoo JJ, Koo KH, Yoon KS, Kim HJ. Alumina-on-alumina total hip arthroplasty: a concise follow-up, at a minimum of ten years, of a previous report. J Bone Joint Surg Am. 2010;92:1715-9.   DOI   ScienceOn
29 Heros R, Willmann G. Ceramic in total hip arthroplasty: history, mechanical properties, clinical results and current state of the art. Seminars Arthroplasty. 1998;9:114-22.
30 Sedel L, Nizard R, Bizot P, Meunier A. Perspective on a 20-year experience with ceramic-on-ceramic articulation in total hip replacement. Semin Arthroplasty. 1998;9:123-34.
31 Koo KH, Ha YC, Jung WH, Kim SR, Yoo JJ, Kim HJ. Isolated fracture of the ceramic head after thirdgeneration alumina-on-alumina total hip arthroplasty. J Bone Joint Surg Am. 2008;90:329-36.   DOI   ScienceOn
32 Ha YC, Kim SY, Kim HJ, Yoo JJ, Koo KH. Ceramic liner fracture after cementless alumina-on-alumina total hip arthroplasty. Clin Orthop Relat Res. 2007;458:106-10.
33 Park YS, Hwang SK, Choy WS, Kim YS, Moon YW, Lim SJ. Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing. J Bone Joint Surg Am. 2006;88:780-7   DOI   ScienceOn
34 Min BW, Song KS, Kang CH, Bae KC, Won YY, Lee KY. Delayed fracture of a ceramic insert with modern ceramic total hip replacement. J Arthroplasty. 2007;22:136-9.   DOI   ScienceOn
35 Toni A, Traina F, Stea S, et al. Early diagnosis of ceramic liner fracture. Guidelines based on a twelve-year clinical experience. J Bone Joint Surg Am. 2006;88 Suppl:55-63.   DOI