Browse > Article
http://dx.doi.org/10.5371/jkhs.2010.22.3.177

Cement Fixation Technique for a Femoral Stem  

Kim, Sung-Kon (Department of Orthopaedic Surgery, Ansan Hospital, College of Medicine, Korea University)
Publication Information
Hip & pelvis / v.22, no.3, 2010 , pp. 177-182 More about this Journal
Abstract
Cemented total hip arthroplasty was first introduced by Sir John Charnley in 1961 and it has become one of the principal fixation techniques for fixation of an implant. The surgical technique has since been modified and this has resulted in improved longevity and reliability. The clinical success of the cemented technique has varied in literature, and this has been reported as 30~40% failure to 2% failure for 14 years of follow up using the 2nd generation cement technique. Currently, the successful clinical results can be contributed to the better developed design of the femoral stem and the advancement of the 3rd and 4th generation cement fixation techniques. As society gains more elderly people, for the older patients who have osteoporosis, a wide and thin femur would be the best indication for cement fixation in order to achieve early stability and better clinical results. It is imperative to learn and practice performing the exact cement fixation technique to achieve the best clinical results.
Keywords
Cement fixation technique; Femoral stem;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Callahan JJ, Rosenberg AG, Rubash HE. The adult hip. Philadelphia: Lippinecott Raven; 1998.959-73.
2 Amstutz HC, Markolf KL, McNeice GM, Gruen TA. Loosening of total hip components: cause and prevention. In: Evarts CM, ed. St. Louis: CV Mosby; 1976.102-16.
3 Stauffer RN. Ten- year follow-up study of total hip replacement. J Bone Joint Surg Am. 1982;64:983-90.   DOI
4 Barrack RL, Mulroy RD Jr, Harris WH. Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review. J Bone Joint Surg Br. 1992;74:385-9.
5 Maltry JA, Noble PC, Kamaric E, Tullos HS. Factors influencing pressurization of the femoral canal during cemented total hip arthroplasty. J Arthroplaty. 1995;10:492-7.   DOI   ScienceOn
6 Majkowski RS, Miles AW, Bannister GC, Perkins J, Taylor GJ. Bone surface preparation in cemented joint replacement. J Bone Joint Surg Br. 1993;75:459-63
7 Burke DW, Gates EI, Harris WH. Centrifugation as a method of improving tensile and fatigue properties of acrylic bone cement. J Bone Joint Surg Am. 1984;66:1265-73.   DOI
8 Goldring SR, Schiller AL, Roelke M, Rourke CM, O'Neil DA, Harris WH. The synovial-like membrane at the bonecement interface in loose total hip replacements and its proposed role in bone lysis. J Bone Joint Surg Am.1983;65:575-84   DOI
9 Jasty M, Jiraneck W, Harris WH. Acrylic fragmentation in total hip replacements and its biologic consequences. Clin Orthop Relat Res. 1992;285:116-28.
10 Kelley SS, Fitzgerald RH Jr, Rand JA, Ilstrup DM. A prospective randomized study of a collar versus a collarless femoral prosthesis . Clin Orthop Relat Res. 1993;294:114-22.
11 Meding JB, Ritter MA, Keating EM, Faris PM, Edmondson K. A comparison of collared and collarless femoral components in primary cemented total hip arthroplasty: a randomized clinical trial. J Arthroplasty 1999;14:123-30.   DOI   ScienceOn
12 Choi D, Park Y, Yoon Y, Masri B. In vitro measurement of interface micormotion and crack in cemented total hip arthroplasty systems with different surface roughness. Clin Biomechanics. 2010;25:50-5.   DOI   ScienceOn
13 Collis DK, Moher CG. Comparison of clinical outcome in total hip arthroplasy using rough and polished cemented stems with essentially the same geometry. J Bone Joint Surg Am. 2002:84-A:586-92.
14 Harris WH, McGann WA. Loosening of the femoral component after use of the medullary-plug cementing technique. Follow-up note with a minimum five-year follow-up. J Bone Joint Surg Am. 1986;68:1064-6.   DOI
15 Davies JP, O'Connor DO, Burke DW, Jasty M, Harris WH. The effect of centrifugation on the fatigue life of bone cement in the presense of surface irregularities. Clin Orthop Relat Res. 1988;229:156-61.
16 Wixson RL, Lautenschlager EP, Novak MA. Vacuum mixing of acrylic bone cement. J Arthroplasty.1987;2:141-9.   DOI   ScienceOn
17 Brand RA, Pedersen DR, Yoder SA. How definition of "loosening"affects the incidence of loose total hip reconstruction. Clin Orthop Relat Res. 1986;210:185-91.
18 Jasty M, Maloney WJ, Bragdon CR, Haire T, Harris WH. Histomorphological studies of the long-term skeletal responses to well fixed cemented femoral components. J Bone Joint Surg Am. 1990;72:1220-9.   DOI
19 Kwong LM, Jasty M, Mulroy RD, Maloney WJ, Bragdon C, Harris WH. The histology of the radiolucent line. J Bone Joint Surg Br. 1992;74:67-73.   DOI
20 Jasty M, Maloney WJ, Bragdon CR, O'Connor DO, Haire T, Harris WH. The initiation of failure in cemented femoral components of hip arthroplasty. J Bone Joint Surg Br. 1991;73:551-8.   DOI
21 Maloney WJ, Jasty M, Burke DW, et al. Biomechanical and histologic investigation of cemented total hip arthroplasties. A study of autopsy-retrieved femurs after in vivo cycling. Clin Orthop Relat Res. 1989;249:129-40
22 Harrigan TP, Karch JA, O'Connor DO, Burke DW, Harris WH. A finite element study of the initiation of failure of fixation in cemented total hip components. J Orthop Res. 1992;10:134-44.   DOI
23 Harrigan TP, Harris WH. A three dimensional non-linear finite element study of the effect of cement-prosthesis debonding in cemented femoral total hip components. J Biomech. 1991;24:1047-58.   DOI   ScienceOn