Abstract
In order to secure the stability against strong earthquakes, isolation devices on the existing nuclear power plant have been introduced. By applying the isolation device on structures, it is possible to isolate structures from the ground motion. Therefore, the natural frequencies of the structures become longer, and the responses of the structures due to the ground motion decrease. Especially, when designing the nuclear power plant, it is important to ensure the safety of internal devices as well as the nuclear power plant itself. The floor response spectrum is commonly used in designing the internal devices. In this research, floor response spectrum is evaluated and the effect of second hardening behavior is investigated by performing earthquake analysis.
Keywords
floor response spectrum; isolation device; second hardening; base-isolated nuclear power plant;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Kim, H.J., Choi, K.S., Yi, W.H., Yang, W.J. (2013) A Study on Evaluation of Floor Response Spectrum for Seismic Design of Non-Structural Components, J. Earthq. Eng. Soc. Korea, 17(6), pp.279-291.   DOI
2 KEPCO & KHNP (2013) APR1400 Design Control Document Rev.0.
3 Mazzoni, S., McKenna, F., Scott, M.H., Fenves, G.L. (2006) OpenSees Command Language Manual, Pacific Earthquake Engineering Research(PEER) Center.
4 McKay, M.D., Beckman, R.J., Conover, W.J. (2000) A Comparison of Three Methods for Selecting Values of Input Variables in the Analysis of Output from a Computer Code, Technometrics, 42(1), pp.55-61.   DOI
5 Nelder, J. A., Mead, R. (1965) A Simplex Method for Function Minimization. The Comput. J., 7(4), 308-313.   DOI
6 U.S. NRC (1978) Regulatory Guide 1.122, Development of Floor Design Response Spectra for Seismic Design of Floor-Supported Equipment or Components.
7 U.S. NRC (1973) Regulatory Guide 1.60, Design Response Spectra for Seismic Design of Nuclear Plants.
8 Wilson, E.L., Habibullah, A. (1998) SAP2000-Structural Analysis Users Manual. Computers and Structures, Inc.