Browse > Article
http://dx.doi.org/10.6113/TKPE.2020.25.4.261

Study on Transformer Saturation in Isolated Full-Bridge DC-DC Converters  

Kim, Jeonghun (School of Energy Eng., Kyungpook Nat'l University)
Cha, Honnyong (School of Energy Eng., Kyungpook Nat'l University)
Publication Information
The Transactions of the Korean Institute of Power Electronics / v.25, no.4, 2020 , pp. 261-268 More about this Journal
Abstract
Transformer saturation in full bridge (FB) isolated DC-DC converters is caused by uneven switching speeds and voltage drops in semiconductor devices and mismatched gate signals. In order to prevent transformer saturation, most popular and widely used approach is to insert a capacitor in series with the transformer windings. This study conducts extensive analyses on transformer saturation and the effect of DC blocking capacitors when they are placed in the primary or secondary windings of a transformer. The effect of the DC blocking capacitors is verified in voltage-fed and current-fed FB converters.
Keywords
Current-fed; DC blocking capacitor; Transformer saturation; Voltage-fed;
Citations & Related Records
연도 인용수 순위
  • Reference
1 F. Z. Peng, H. Li, G. J. Su, and J. S. Lawler, “A new ZVS bidirectional DC-DC converter for fuel cell and battery application,” IEEE Transactions on Power Electronics, Vol. 19, No. 1, pp. 54-65, Jan. 2004.   DOI
2 P. He and A. Khaligh, “Comprehensive analyses and comparison of 1 kW isolated DC-DC converters for bidirectional EV charging systems,” IEEE Transactions on Transportation Electrification, Vol. 3, No. 1, pp. 147-156, Mar. 2017.   DOI
3 F. Krismer and J. W. Kolar, “Efficiency-optimized high-current dual active bridge converter for automotive applications,” IEEE Transactions on Industrial Electronics, Vol. 59, No. 7, pp. 2745-2760, Jul. 2012.   DOI
4 G. Ortiz, L. Fässler, J. W. Kolar, and O. Apeldoorn, “Flux balancing of isolation transformers and application of “The magnetic ear” for closed-loop volt-second compensation,” IEEE Transactions on Power Electronics, Vol. 29, No. 8, pp. 4078-4090, Aug. 2014.   DOI
5 J. Muhlethaler, J. Biela, J. W. Kolar, and A. Ecklebe, "Core losses under the DC bias condition based on steinmetz parameters" IEEE Transactions on Power Electronics, Vol. 27, No. 2, pp. 953-963, Feb. 2012.   DOI
6 R. W. Erickson and D. Maksimovi'c, Fundamentals of Power Electronics, Second Edition, Springer Science+ Business Media, LLC, 2001.
7 O. Garcia, P. Zumel, A. D. Castro, P. Alou, and J. Cobos, “Current self-balance mechanism in multiphase buck converter,” IEEE Transactions on Power Electronics, Vol. 24, No. 6, pp. 1600-1606, Jun. 2009.   DOI
8 G. Buticchi and E. Lorenzani, “Detection method of the DC bias in distribution power transformers,” IEEE Transactions on Industrial Electronics, Vol. 60, No. 8, pp. 3539-3549, Aug. 2013.   DOI
9 S. Klopper and J. A. Ferreira, “A sensor for balancing flux in converters with a high-frequency transformer link,” IEEE Transactions on Industry Applications, Vol. 33, No. 3, pp. 774-779, May/Jun. 1997.   DOI
10 P. Ripka and M. Janosek, “Advances in magnetic field sensors,” IEEE Sensors Journal, Vol. 10, No. 6, pp. 1108-1116, Jun. 2010.   DOI
11 A. Pressman, Switching Power Supply Design, McGraw-Hill, Inc., 1998.