Loss Analysis of Pulse Type Inverter Circuit for PLS  

Jung, Yong-Chae (남서울대 전자공학과)
Jung, Yun-Chul (LG전자)
Publication Information
The Transactions of the Korean Institute of Power Electronics / v.11, no.6, 2006 , pp. 489-493 More about this Journal
Abstract
The aim of the paper is to design the PLS(Plasma Lighting System) driving inverter circuit with optimal efficiency. In general, it is known that the PLS driven by a pulse has a higher light-conversion efficiency. There are the Class-E type resonant inverter and the semi-bridge inverter as a circuit which can make a pulse with low duty ratio. In this paper, we analyze the losses of the above two circuits. To verify the loss analysis, the inverter circuit with 220V 380W input consumption is manufactured and tested. Throughout the experimental results, the high efficiency PLS system has confirmed.
Keywords
PLS; Plasma Lighting System; Inverter; High Efficiency; Loss Analysis;
Citations & Related Records
연도 인용수 순위
  • Reference
1 정윤철, 최준식, 정용채, '무전극 플라즈마 램프 구동용 인버터 회로', 전력전자학회지, 제10권, 제2호, pp. 21-24, 2005년, 4월
2 http://www.lgelight.co.kr
3 정봉만, 한수빈, 정학근, '신 조명기술', 제16회 에너지절약기술 Workshop 논문집, pp. 409-416, 2001
4 황명근, 이세현, 조미령, 신상욱, 허현수, 배영진, '마이크로웨이브를 이용한 무전극 플라즈마 램프의 구성과 기술 동향', 제18회 에너지절약기술 Workshop 논문집, pp. 427-433, 2003
5 Wharmby, D. O., 'Electrodeless Lamps for Lighting : A Review,' IEE Proceedings A, Vol. 140, No. 6, November 1993
6 배영진, '무전극 램프의 상용화 기술', 대한전기학회 전기의 세계, 제51권, 제1호, pp. 20-23, 2002
7 김진중, 홍성호, 김정원, '초고주파 방전 광원 기술', 제16회 에너지절약기술 Workshop 논문집, pp. 427-433, 2001