Abstract
The radiation dosage of nuclear fuel handling machine of PHWR type NPP during normal operation is measured using semiconductor detectors. In order to predict and mitigate the damage of main components in fuel handling machine, caused by high irradiation, the radiation dosage exerted to the components by neutron and gamma ray is measured independently during one time of the fuel exchange, which is used far estimating the radiation dosage for one year. This result can guarantee the safety and economical efficiency for determining the replacement time of the high cost main components in fuel handling machine.
Keywords
semiconductor; radiation; nuclear; neutron; fuel handling machine; gamma-ray;
Citations & Related Records
연도 인용수 순위
  • Reference
1 G. Mackay, I. Thomson, C. R. Himing, and M. Zeya: 'Gamma-ray Dose Mapping in Operational CANDU Reactor Containment Areas using MOS Dosimeters,' ASTM publication, pp. 441-446, 1994
2 P. N. Cooper: Introduction on Nuclear Radiation Detector, Cambridge University Press, pp. 84-96, 1986
3 A. Holmes-Siedle, L. Adams, J. Stephen Leffler, and Steven R. Lindgren: 'The RADFET System for Real-Time Dosimeer in Nuclear Facility,' IEEE Trans. Nucl. Sci., 1983
4 M. McPherson, T. Sloan, B. K. Jones, 'Suppression of Irradiation Effect in Gold-Doped Silicon Detectors', J. Phys. D: Appl. Phys. 30, pp. 3028-3035, 1997   DOI   ScienceOn
5 N. H. Lee et all, 'Development of Fast Neutron Detector and its Characteristics', KIEE Annual Summer Cong., 2003
6 J. M. Swartz and M. O. Thurston, 'Analysis of the Effect of Fast-Neutron Bombardment on the Current-Voltage Characteristic of a Conductivity-Modulated P-I-N Diode,' J. Appl. Phys. 37 no. 2, pp. 745-755, 1966   DOI
7 A. Holmes-Siedle: 'The Space-Charge Dosimeter,' Nuclear. Instruments. & Methods, vol. 121, pp. 169-179, 1974   DOI   ScienceOn