Browse > Article
http://dx.doi.org/10.5207/JIEIE.2010.24.12.147

A Study on the Improvement of Test and Diagnosis Device for Audio Frequency Track Circuit  

Kang, Jang-Kyu (대한전기학원)
Kim, Jae-Chul (숭실대학교 전기공학부)
Publication Information
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers / v.24, no.12, 2010 , pp. 147-155 More about this Journal
Abstract
We studied on performance improvement of TTM(TI21 Test Meter) that is test and diagnosis devices for jointless audio frequency track circuit on Korean electric railway TI21 standard. Upgraded devices is AD-TTM(Advanced TI21 Test Meter). This can measure alternating frequency USB(Upper signal band) and LSB(Lower signal band). In the audio frequency track circuit, ${\pm}17[Hz]$ of nominal frequency are demodulated and supplied to track relay through AND gate. It is important that measurement function which is error between USB and LSB. Need of AD-TTM will stand out in the electric railway system because this is simple and accurate rather than the former device.
Keywords
Jointless Audio Frequency track circuit; TTM(TI21 Test Meter); AD-TTM(Advanced TI21 Test Meter);
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 KIM Yong-Kyu, BAEK Jong-Hyun, RYU Chang-Keun, “A Study on the track circuit characteristic in electrified classical line”, 대한전기학회 하계학술대회 논문집,pp. 1397-1399, 2004.   과학기술학회마을
2 N.Nedelchev, “Jointless track circuit length ”., IEE Proc., Electr. Power Appl, Vol. 146, Issue 1, p.69–74, January 1999.   DOI
3 Kim min-cheol, Jang Dong-Uk, Lee jang-moo, Han moon-seob, Heo nam-yeong, Shin myung-cheol “Study for an estimation of conducted noise between electric train and track circuit by analyzing harmonics” 대한전기학회 하계학술대회 논문집 pp.2360-2362, 2005.   과학기술학회마을
4 김영태, “철도신호제어시스템”, 테크미디어, p40-46, 2006.
5 한국철도표준규격, "KRS-SG-0038-07(R) 무절연가청주파수(AF)궤도회로", p1-2, p10-15, 2006.