A Research of Optimum Supply Reserve Levels for Stability of Power System  

Ahn, Dae-Hoon (한국전력거래소 수급계획과)
Kwon, Seok-Kee (한국전력거래소 수급계획과)
Joo, Haeng-Ro (한국전력거래소 수급계획과)
Choi, Eun-Jae (한국전력거래소 수급계획과)
Publication Information
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers / v.22, no.9, 2008 , pp. 55-61 More about this Journal
Abstract
Because of the high increasing rate of load demand these days the necessity of deciding what optimum reserve level is appropriate to most stably supply electricity is being emphasized. This research studies the downward tendency of reserve ratio by analyzing the trend of change of the network scale, reserve, and reserve ratio while optimum reserve has been increased as the network system scale grow up. This means, at this moment 6,000[MW] is optimum level for short term prospect of power supply and demand. And also, it has been analyzed that, as the annual peak load exceeded 50,000[MW], confirming the amount of optimum reserve level is more stable than keeping 10 to 12[%] reserve ratio.
Keywords
Reserve Classification; Installed Reserve; Supply Reserve; Operating Reserve; Reserve Ratio;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Korea Power Exchange, 'Power Market Rule', pp44-46, 2008. 1
2 D.H.Ahn, 'An examination report for reasonable supply reserve', Korea Power Exchange, 2007. 4
3 H.R.Joo, 'The research of ensuring reasonable reserve in compliance with power industry reconstruction', A treatise of SNU's manager course for KEPCO staffs, 2004. 12
4 Korea Power Exchange, 'The research of reasonable operating reserve standards and estimated reserve quantity', 2002. 10
5 D.H.Ahn, 'The prospects for power supply and demand and resource outage schedule from 2008 to 2009', Korea Power Exchange, 2007. 10