Adaptation of Sensory Nerve Afferents for Selective Elicitation of Tactile Sensations
![]() |
An, Boyoung
(Department of Biomedical Engineering, Kyung Hee University)
Ma, Joohyung (Department of Biomedical Engineering, Kyung Hee University) Hwang, Sun Hee (Department of Neurology, Samsung Medical Center) Song, Tongjin (Department of Biomedical Engineering, Jungwon University) Khang, Gon (Department of Biomedical Engineering, Kyung Hee University) |
1 | Vallbo, B., Olsson, K., Westberg, K., and Clark, F., "Microstimulation of Single Tactile Afferents from the Human Hand," Brain, Vol. 107, No. 3, pp. 727-749, 1984. DOI |
2 | Johansson, R. S., Landstrom, U., and Lundstrom, R., "Responses of Mechanoreceptive Afferent Units in the Glabrous Skin of the Human Hand to Sinusoidal Skin Displacements," Brain Research, Vol. 244, No. 1, pp. 17-25, 1982. DOI |
3 | Ochoa, J. and Torebjork, E., "Sensations Evoked by Intraneural Microstimulation of Single Mechanoreceptor Units Innervating the Human Hand," The Journal of Physiology, Vol. 342, No. 1, pp. 633-654, 1983. DOI |
4 | Carrozza, M. C., Cappiello, G., Micera, S., Edin, B. B., Beccai, L., et al., "Design of a Cybernetic Hand for Perception and Action," Biological Cybernetics, Vol. 95, No. 6, pp. 629-644, 2006. DOI |
5 | Tyler, D. J. and Durand, D. M., "Functionally Selective Peripheral Nerve Stimulation with a Flat Interface Nerve Electrode," IEEE Transactions on Neural Systems and Rehabilitation Engineering, Vol. 10, No. 4, pp. 294-303, 2002. DOI |
6 | Kajimoto, H., Kawakami, N., Maeda, T., and Tachi, S., "Electrocutaneous Display with Receptor Selective Stimulations," Electronics and Communications in Japan (Part II: Electronics), Vol. 85, No. 6, pp. 40-49, 2002. DOI |
7 | Kajimoto, H., Kawakami, N., and Tachi, S., "Optimal Design Method for Selective Nerve Stimulation and Its Application to Electrocutaneous Display," Proc. of the Haptic Interfaces for Virtual Environment and Teleoperator Systems, pp. 303-310, 2002. |
8 | Ara, J., Hwang, S. H., Song, T., and Khang, G., "Effects of the Stimulus Parameters on the Tactile Sensations Elicited by Single-Channel Transcutaneous Electrical Stimulation," Int. J. Precis. Eng. Manuf., Vol. 15, No. 2, pp. 305-313, 2014. DOI |
9 | Hwang, S. H., Song, T., and Khang, G., "Perception Intensity and Frequency of Pressure and Vibration Elicited by Electrical Stimulation," Proc. of the International Conference on Life Science and Biological Engineering, pp. 952-959, 2014. |
10 | Crook, M. N. and Crook, H., "Adaptation to Cutaneous Pressure," The American Journal of Psychology, Vol. 47, No. 2, pp. 301-308, 1935. DOI |
11 | Ma, J., Khang, G., An, B., Hwang, S. H., and Song, T., "Quantification of the Perception Intensity of Electrically-Elicited Pressure Sensation," Proc. of KSPE Spring Conference, pp. 973-974, 2015. |
12 | Zigler, M. J., "Pressure Adaptation-Time: A Function of Intensity and Extensity," The American Journal of Psychology, Vol. 44, No. 4, pp. 709-720, 1932. DOI |
13 | Bensmaia, S. J., Leung, Y. Y., Hsiao, S. S., and Johnson, K. O., "Vibratory Adaptation of Cutaneous Mechanoreceptive Afferents," Journal of Neurophysiology, Vol. 94, No. 5, pp. 3023-3036, 2005. DOI |
14 | An, B., Khang, G., Hwang, S. H., and Song, T., "Effects of the Previous Stimulation on the Electrically-Elicited Tactile Sensation," Proc. of KSPE Spring Conference, p. 1195, 2014. |
![]() |