Browse > Article

Variation of Paraspinal Muscle Forces according to the Lumbar Motion Segment Fusion during Upright Stance Posture  

Kim, Young-Eun (Department of Mechanical Engineering, Dakook Univ.)
Choi, Hae-Won (Graduate School, Department of Mechanical Engineering, Dakook Univ.)
Publication Information
Abstract
For stability analysis of the lumbar spine, the hypothesis presented is that the disc has stress sensors driving feedback mechanism, which could react to the imposed loads by adjusting the contraction of the muscles. Fusion in the motion segment of the lumbar spinal column is believed to alter the stability of the spinal column. To identify this effect finite element (FE) models combined with optimization technique was applied and quantify the role of each muscle and reaction forces in the spinal column with respect to the fusion level. The musculoskeletal FE model was consisted with detailed whole lumbar spine, pelvis, sacrum, coccyx and simplified trunk model. Vertebral body and pelvis were modeled as a rigid body and the rib cage was constructed with rigid truss element for the computational efficiency. Spinal fusion model was applied to L3-L4, L4-L5, L5-S1 (single level) and L3-L5 (two levels) segments. Muscle architecture with 46 local muscles was used as acting directions. Minimization of the nucleus pressure deviation and annulus fiber average axial stress deviation was selected for cost function. As a result, spinal fusion produced reaction changes at each motion segment as well as contribution of each muscle. Longissimus thoracis and psoas major muscle showed dramatic changes for the cases of L5-S1 and L3-L5 level fusion. Muscle force change at each muscle also generated relatively high nucleus pressure not only at the adjacent level but at another level, which can explain disc degeneration pattern observed in clinical study.
Keywords
Paraspinal Muscle Force; Finite Element Model; Optimization Method; Fusion;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Rohlmann, A., Neller, S., Claes, L., Bergmann, G. and Wilke, H. J., "Influence of a Follower Load on Intradiscal Pressure and Intersegmental Rotation of the Lumbar Spine," Spine, Vol. 26, No. 24, pp. 557-561, 2001.   DOI   ScienceOn
2 Lu, Y. M., Hutton, W. C. and Gharpuray, V. M., "The Effect of Fluid Loss on the Viscoelastic Behavior of the Lumbar Intervertebral Disc in Compression," J. of Biomed. Eng., Vol. 120, No. 1, pp. 48-54, 1998.
3 Santaguida, P. L. and McGill, M., "The Psoas Major Muscle: A Three-Dimensional Geometric Study," J. Biomechanics, Vol. 28, No. 3, pp. 339-345, 1995.   DOI   ScienceOn
4 Wai, M. S., Santos, E. R. G., Morcom, R. A. and Fraser, R. D., "Magnetic Resonance Imaging 20 Years After Anterior Lumbar Interbody Fusion," Spine, Vol. 31, No. 17, pp. 1952-1956, 2006   DOI   ScienceOn
5 Chen, C. S., Cheng, C. K., Liu, C. L. and Lo, W. H., "Stress Analysis of the Disc Adjacent to Interbody Fusion in Lumbar Spine," Medical Engineering & Physics, Vol. 23, No. 7, pp. 483-491, 2001.
6 Pintar, F. A., "The Biomechanics of Spinal Elements," Doctoral Dissertation, Department of Biomedical Engineering, Marquette University, 1986.
7 Shirazi-Adl, A. and Parnianpour, M., "Load Bearing and Stress Analysis of the Human Spine under a Novel Wrapping Compression Load," Clinical Biomechanics, Vol. 15, No. 10, pp. 718-725, 2000.   DOI   ScienceOn
8 Cholewicki, J., McGill, S. M. and Norman, R. W., "Comparison of Muscle Forces and Joint Load from an Optimization and EMG Assisted Lumbar Spine Model: towards Development of a Hybrid Approach," J. of Biomechanics, Vol. 28, No. 3, pp. 321-331, 1995.   DOI   ScienceOn
9 Penning, L., "Psoas Muscle and Lumbar Spine Stability: A Concept Uniting Existing Controversies," Eur. Spine J., Vol. 9, No. 6, pp. 577-585, 2000.   DOI   ScienceOn
10 White III, A. A. and Panjabi, M. M., "Clinical biomechanics of the Spine," Lippincott Williams & Wilkins, pp. 1-83, 1990.
11 Kim, Y. E. and Kim, S. T, "Stress Sensors Driving a Feedback Mechanism for the Prediction of Paraspinal Muscle Forces during Upright Stance Posture," J. of Biomechanical Science and Engineering, Vol. 3, No. 3, pp. 419-430, 2008.   DOI
12 Patwardhan, A. G., Havey, R. M., Meade, K. P., Lee, B. and Dunlap, B., "A Follower Load Increases the Load-Carrying Capacity of the Lumbar Spine in Compression," Spine, Vol. 24, No. 10, pp. 1003-1009, 1999.   DOI   ScienceOn
13 Kim, Y. E., Goel, V. K., Lim, T.-H. and Weinstein, J., "Effect of Disc Degeneration at one Level on the Adjacent Level in Axial Mode," Spine, Vol. 16, No. 3, pp. 331-335, 1991.   DOI   ScienceOn
14 Renner, S. M., Natarajan, R. N., Patwardhan, A. G., Havey, R. M., Voronov, L. I., Guo, B. Y., Andersson, G. B. and An, H. S., "Novel Model to Analyze the Effect of a Large Compressive Follower Pre-load on Range of Motions in a Lumbar Spine," J. of Biomechanics, Vol. 40, No. 6, pp. 1326-1332, 2007.   DOI   ScienceOn
15 Kim, Y. E. and Yun, S. S., "Effect on the Adjacent Motion Segments according to the Artificial Disc Insertion," Journal of Korean Society for Precision Engineering, Vol. 24, No. 8, pp. 122-129, 2007.