Browse > Article

A Calibration Method Using Four Fiducials Applicable to Nonlinear Displacement of PCBs on SMT Devices  

Jang, Chan-Soo (삼성테크원 정밀기기연구소)
Kim, Yung-Joon (삼성테크원 정밀기기연구소)
Kim, Jae-Ok (삼성테크원 정밀기기연구소)
Publication Information
Abstract
A new position correction method using four fiducials as reference points was developed and examined. It was aimed to calibrate nonlinear deformation by numerous error sources. A correlation for correction was derived from the geometric relationship between four fiducials and chip position. Compared with three points method, it exhibited more accurate correction, especially for inner area of a quadrilateral composed of four fiducial points. Its accuracy was found to be increased as fiducials moves outwardly within a printed circuit board (PCB) and/or as they form more rectangle-like shape As for arbitrarily nonlinear deformation, this method can be applied using more than five fiducials. In this case, local-area calibration is carried out by sectioning a board area into several rectangular are as.
Keywords
Surface mount technology; Fiducial; Placement position and angle;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 안정호, '두 보정면과 사교좌표 매핑을 이용한 카메라 보정법,' 한국 정밀공학회지, 제 16권, 제 7호, pp. 119-124, 1999   과학기술학회마을
2 Ray, R., 'Placement of Surface Mount Components: Machine Accuray and Performance Modeling,' IEEE Conf. Systems, Man and Cybernetics, Vol. 2, pp. 1746-1752, 1995   DOI