Browse > Article
http://dx.doi.org/10.22156/CS4SMB.2019.9.3.128

Discussion on the Value of Using Gait Analysis System Using Smart Shoes  

Park, Tae-Sung (Biomedical Research Institude, Pusan National University Hospital)
Shin, Myung-Jun (Department of Rehabilitation Medicine, Pusan National University Hospital)
Lee, Lee-Eun (Biomedical Research Institude, Pusan National University Hospital)
Publication Information
Journal of Convergence for Information Technology / v.9, no.3, 2019 , pp. 128-133 More about this Journal
Abstract
The purpose of this study is to verify whether the data measured by the researcher and the smart shoe sensor data are the same or similar by performing the 6 - minute walking test and time up and go test after putting smart shoes on a normal person. Ten normal adult males participated. After wearing smart shoes, they performed a 6-minute walk test and a time up and go test. The results of this experiment show that the accuracy of the current sensor is high. The difference in the distance of the 6-minute walking test is that the difference is because the turning point, which is not calculated in the actual 30-m track, measures the distance. From this point of view, it can be seen that smart shoes measure more accurate distance and it is expected that various tests will be possible through smart sensors.
Keywords
Shoes; Sensor; 6-minute walk test; Time up and go test; smart shoes;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 A. Schmid et al. (2007). Improvements in speed-based gait classifications are meaningful. Stroke, 38(7), 2096-100.   DOI
2 H. R. Jung & D. W. Oh. (2017). Influence of Walking Capacity and Environment on the Outcomes of Shortand Long-distance Walking Velocity Tests in Individuals with Chronic Stroke. Physical Therapy Korea, 24(3), 01-09.   DOI
3 S. J. Choi & D. W. Oh. (2012). The Effects of Intensive Chest Mobility Exercise on Increasing Pulmonary Function and Gait in Stroke Patients. Journal of Special Education & Rehabilitation Science, 51(2), 221-239.
4 S. M. Sim & D. W. Oh. (2011). Use of the 6-Minute Walk Test as Gait Therapy for Hemiplegic Patients: Possibility of Practice Effect by Providing Knowledge of Result. Korean Journal of Health Promotion. 11(1), 42-47.
5 J. S. Park & J. Y. Park. (2016). Market trends and business opportunities of the smart insole technology. Journal of the Korea Institute of Information and Communication Engineering, 20(7), 1389-1397.   DOI
6 C. H. Kim et al. (2008). Predicting Oxygen Uptake for Men with Moderate to Severe Chronic Obstructive Pulmonary Disease. Tuberculosis and Respiratory Diseases, 64(6), 1433-438.
7 S. H. Lee & B. Y. Hwang. (2008). The Correlations among the Dynamic Gait Index the Berg Balance Scale and Timed Up & Go Test in people with strokel. The journal of Korean academy of physical therapy science. 15(3), 1-8.
8 S. B. Park et al. (2014). Development of smart shoes with personalized mobile health management system. Eromonomics Society of Korea, 11, 141-144.
9 S. P. Jun, Y. Y. You & S. B. Park. (2016). Development of Smart Shoe with Musculoskeletal Injury Prevention and Monitoring System. Korean Society of precision engineering, 10, 599-600.
10 E. Myagmar, T. S. Kim & S. R. Kwon. (2017). Real Time Healthcare System using Smart Shoes. THE INSTITUTE OF ELECTRONICS ENGINEERS OF KOREA, 6, 1372-1373.
11 S. B. Park & S. K. Park. (2009). Validation of SMART technology controller's ability to calculate metabolic energy expenditure. The Korean Journal of Physical Education, 48(3), 499-506.
12 S. M. Kim. (2018). A Study on the Design Plan of UX for the Smart Healthcare for the Aged Society - Focused on IOT Technology. Jour. of KoCon.a, 18(11), 462-474.
13 G. Y. Lee & D. M. Lee. (2018). A Study on the Future Bathroom Coupled with Smart Healthcare System. Journal of the Korea Convergence Society, 9(3), 203-209   DOI