Fenton oxidation method using hydrogen peroxide is an eco-friendly oxidation method used in water treatment and soil restoration. When removing pollutants by this method, it is quite important to properly regulate the concentration of hydrogen peroxide according to the concentration of the contaminants. In this study, electrochemical biosensors using HRP (horseradish peroxidase) enzymes were manufactured and studies were conducted on the activity of enzymes and the detection characteristics of hydrogen peroxide. HRP were electro deposited with chitosan and AuNP on the working electrode surface of the SPCE (Screen Printed Carbon Electrode). Then, the fixation of enzymes was confirmed using the cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The activity of HRP enzymes was also identified from chronoamperometry (CA) and UV spectroscopy. After immersing the biosensor in PBS solution the current generated from electrodes by titrating hydrogen peroxide was measured from CA analysis. The generated current increased linearly for the concentration of hydrogen peroxide, and a calibration curve was derived that could predict the concentration of hydrogen peroxide from the current.
Keywords
Biosensor; Hydrogen peroxide; Electrochemistry; Horseradish peroxidase;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 A. J. Bard, 'Electochemical methods', Wiley, chapter 6 and 11 (2001).
2 Jr. D. K. Gosser, 'Cyclic voltammetry simulation and analysis of reaction mechanisms', VCH Publishers, chapter 2 (1993).
3 B. W. Park, D. S. Kim and D. Y. Yoon, 'Surface modification of gold electrode with gold nanoparticles and mixed self-assembled monolayers for enzyme biosensors', Korean Journal of Chemical Engineering, 28, 64 (2011).   DOI
4 Y. Liu, T. Geng and J. Gao, 'Layer-by-layer immobilization of horseradish peroxidase on a gold electrode modified with colloidal gold nanoparticles', Microchmica Acta, 161, 241 (2008).   DOI
5 B. Y. Chang and S. M. Park, 'Electrochemical impedance spectroscopy', Annual Review of Analytical Chemistry, 3, 207 (2010).   DOI
6 S. M. Park and J. S. Yoo, 'Electrochemical impedance spectroscopy for better electrochemical measurements', Analytical Chemistry, November 1, 459A (2003).
7 B. Y. Park, K. Ko, D. Y. Yoon and D. S. Kim, 'Enzyme activity assay for horseradish peroxidase encapsulated in peptide nanotubes', Enzyme and Microbial Technology, 51, 81 (2012).   DOI
8 B. Neiman, E. Grushka and O. Lev, 'Use of gold nanoparticles to enhance capillary electrophoresis', Analytical Chemistry, 73, 5220 (2001).   DOI
9 A. N. P. Hiner, J. Hernandez-Ruiz, M. B. Arnao, F. Garcia-Canovas and M. Acosta, 'A comparative study of the purity, enzyme activity, and inactivation by hydrogen peroxide of commercially available horseradish peroxidase isoenzymes A and C', Biotechnology and Bioengineering, 50, 609 (1996).   DOI
10 X. Xu, S. Liu and H. Ju, 'A novel hydrogen peroxide sensor via the direct electrochemistry of horseradish peroxidase immobilized on colloidal gold modified screen-printed electrode', Sensors, 3, 350 (2003).   DOI
11 S. K. Rahul, M. Basavaraju, and S. Shrihari, 'Fenton and photo-Fenton oxidation processes for degradation of 3-aminopyridine from water', APCBEE Procedia, 9, 25 (2014).   DOI
12 H. L. Zhang, G. S. Lai, D. Y. Han and A. M. Yu, 'An amperometric hydrogen peroxide biosensor based on immobilization of horseradish peroxidase on an electrode modified with magnetic dextran microspheres', Analytical and Bioanalytical Chemistry, 390, 971 (2008).   DOI
13 B. W. Park, R. Zheng, K. Ko, B. D. Cameron, D. Y. Yoon and D. S. Kim, 'A novel glucose biosensor using bi-enzyme incorporated with peptide nanoparticles', Biosensors and Bioelectronics, 38, 295 (2012).   DOI
14 L. B. Sagle, K. R. Laura, A. R. Julia and P. V. D. Richard, 'Advances in localized surface plasmon resonance spectroscopy biosensing', Nanomedicine, 6, 1447 (2011).   DOI
15 L. Rassaei, M. Amiri, C. M. Cirtiu, M. Sillanpaa, F. Marken and M. Sillanapaa, 'Nanoparticles in electrochemical seonsors for environmental monitoring', Trends in Analytical Chemistry, 30, 1704 (2011).   DOI
16 J. P. Hart, A. Crew, E. Crouch, K. C. Honeychurch and R. M. Pemberton, 'Some recent designs and developments of screen-printed carbon electrochemical sensors/biosensors for biomedical, environmental, and industrial analyses', Analytical Letters, 37, 789 (2004).   DOI
17 O. D. Renedo, M. A. Alonso-Lomillo and M. J. A. Martinez, 'Recent developments in the field of screen-printed electrodes and their related applications', Talanta, 73, 202 (2011).   DOI
18 S. Cosnier, 'Biosensors based on electropolymerized films: new trends', Analytical and Bioanalytical Chemistry, 377, 507 (2003).   DOI
19 E. Llaudet, N. P. Botting, J. A. Crayston and N. Dale, 'A three-enzyme microelectrode sensor for detecting purine release from central nervous system', Biosensors and Bioelectronics, 18, 43 (2003).   DOI
20 V. Kavitha and K. Palanivelu, 'Destruction of cresols by Fenton oxidation process', Water Research, 39, 3062 (2005).   DOI
21 K. H. Ro, Y. I. Choi, J. H. Jung. S. H. Jang, and B. G. Jung, 'Degradation characteristics of diesel-contaminated soil according to hydrogen peroxide ($H_2O_2$) concentrations', J. of the Korean Society for Environmental Technology, 19, 391 (2018).   DOI
22 S. Ledru, N. Ruille and M. Boujtita, 'One-step screen-printed electrode modified in its bulk with HRP based on direct electron transfer for hydrogen peroxide detection in flow injection mode', Biosensors and Bioelecronics, 21, 1591 (2006).   DOI
23 T. Tangkuaram, C. Ponchio, T. Kangkasomboon, P. Katikawong and W. Veerasai, 'Design and development of a highly stable hydrogen peroxide biosensor on screen printed carbon electrode based on horseradish peroxidase bound with gold nanoparticles in the matrix of chitosan'. Biosensors and Bioelectronics, 22, 2071 (2007).   DOI
24 J. Zhang and M. Oyama, 'A hydrogen peroxide sensor based on the peroxidase activity of hemoglobin immobilized on gold nanoparticles-modified ITO electrode', Electrochimica Acta, 50, 85 (2004).   DOI