Browse > Article
http://dx.doi.org/10.5229/JKES.2014.17.4.216

Voltammetric Determination of Clenbuterol on Electrochemically Activated Glassy Carbon Electrode  

Lee, Sohee (Graduate School of Convergence Science and Technology, Seoul National University)
Piao, Yuanzhe (Graduate School of Convergence Science and Technology, Seoul National University)
Publication Information
Journal of the Korean Electrochemical Society / v.17, no.4, 2014 , pp. 216-221 More about this Journal
Abstract
A rapid and sensitive voltammetric method for the quantitative determination of Clenbuterol on electrochemically activated glassy carbon electrode has been developed. Using differential pulse voltammetry, the linear response range for the clenbuterol was between $1{\times}10^{-7}$ and $2{\times}10^{-5}M$, and the detection limit was $6{\times}10^{-9}M$ (S/N = 3). The relative standard derivation was 4.3% for $1{\times}10^{-6}M$ clenbuterol. Recoveries of 96% of the clenbuterol (n = 3) were obtained from urine spiked with different amounts in the ranges $5{\times}10^{-7}M$ and $1{\times}10^{-6}M$ by this method.
Keywords
Clenbuterol; Electrochemically activated glassy carbon electrode; Glassy carbon electrode; Cyclic voltammetry; Differential pulse voltammetry;
Citations & Related Records
연도 인용수 순위
  • Reference
1 A. R. Barry and M. M. Graham, J. Cardiol. Cases, 2013, 8, 131.   DOI
2 P. Gustin, M. Ansay and G. Maghuin-Rogister, Ann. Med. Ve., 1988, 62, 371.
3 G. Van Vyncht, S. Preece, P. Gaspar, G. Maghuin-Rogister and E. Depauw, J. Chromatogr., 1996, 750, 43.   DOI
4 H. H. D. Meyer, L. Rinke and I. Dursch, J. Chromatogr., 1991, 564, 551.   DOI
5 J. Girault and J.B. Fourtillan, J. Chromatogr., 1990, 518, 4.
6 B. A. Rashida, P. Kwasowskib and D. Stevenson, J. Pharm. Biomed. Anal., 1999, 21, 635.   DOI
7 P. Gonzaleza, C. A. Fenteb, C. Francoc, B. Vazquezc, E. Quintoc and A. Cepedac, J. Chromatogr. B, 1997, 693, 321   DOI
8 C. Lopez-Erroz, P. Vinas, F. J. Cerdan and M. Hernandez-Cordoba, Talanta, 2000, 53, 47.   DOI
9 M. Hernandez-Carrasquilla, Anal. Chim. Acta, 2000, 408, 285   DOI
10 L. X. Whaites and E. J. Murby, J. Chromatogr. B, 1999, 728, 67.   DOI
11 C. Gausepohl and G. Blaschke, J. Chromatogr. B, 1998, 713, 443.   DOI
12 A. Gleixner.; H. Sauerwein; H. H. D. Meyer, Clinical Chemistry, 1996, 42, 1869.
13 A. Polettini, G. M. Bouland, and M. Montagna, Anal. Chem., 1998, 70, 1362.   DOI
14 G. A. Qureshi and A. Eriksson, J. Chromatogr., 1988, 441, 197.   DOI
15 S. Moanea, M. R. Smyth and M. O'Keeffe, Analyst, 1996, 121, 779.   DOI
16 T. Nagaoka, T. Yoshino, Anal. Chem. ,1986, 58, 1037.   DOI
17 A. L. Beilby, T. A. Sasaki, H MStern, Anal. Chem., 1995, 67, 976.   DOI
18 K. Shi, K. K. Shiu, Anal. Chem., 2002, 74, 879.   DOI
19 Z. N. Zhang, C. H. Lei, W. L. Sun, H. Y. Liu, J. Q. Deng, J. Electroanal. Chem., 1996, 419, 85.   DOI
20 R. L. McCreery, Electroanalytical Chemistry, 1991, 17, 221.
21 K. K. Shiu, F. Y. Song, Electroanalysis, 1998, 10, 256.   DOI
22 M. L. Bowers, B. A. Yenser, Anal. Chim. Acta, 1991, 243, 43.   DOI
23 K. K. Shiu and K. Shi, Electroanalysis, 2000, 12, 134.   DOI
24 Y, Kong, X. Chen, C. Yao, M. Ma and Z. Chen, Anal. Methods, 2011, 3, 2121   DOI
25 G. A. Qureshi and A. Eriksson, J. Chromatogr., 1988, 441, 197.   DOI
26 B. Bo, X. J. Zhu, P. Miao, D. Pei, B. Jiang, Y. Lou, Y. Q. Shu, G. X. Li, Talanta, 2013, 113, 36.   DOI
27 R. R. Gaichore, A. K. Srivastava, J. Appl. Electrochem., 2012, 42, 979.   DOI
28 P. Mial, K. Han, H. Sun, J. Yin, J. Zhao, B. Wang, Y. Tang, ACS Appl. Mater. Interfaces, 2014, 6, 8667.   DOI
29 S. Collins, M. O'keeffe and M. R. Smyth, Analyst, 1994, 119, 2671.   DOI
30 S. Moanea, J. B. Rodrigueza, A. J. M. Ordieresa, P. T. Blancoa and M. R. Smyth, J. Pharm. Biomed. Anal., 1995, 14, 57.   DOI
31 J.Bai, Y. J. Lai, D. W. Jiang, Y. B. Zeng, Y. Z. Xian, F. Xiao, N. D. Zhang, J. Hou, L. T. Jin, Analyst 2012, 137, 4349.   DOI