Simple Electrochemical Immunosensor for the Detection of Hippuric Acid on the Screen-printed Carbon Electrode Modified Gold Nanoparticles  

Choi, Young-Bong (Department of chemistry, Dankook University)
Tae, Gun-Sik (Department of Life Sciences, Dankook University)
Publication Information
Journal of the Korean Electrochemical Society / v.14, no.1, 2011 , pp. 44-49 More about this Journal
Abstract
This paper describes an electrochemical immunosensor for simple, fast and quantitative detection of a urinary hippuric acid which is one of major biological indicator in toluene-exposed humans. The feature of this electrochemical system for immunoassay of hippuric acid is based on the direct conjugation of ferrocene to a hippuric acid. With the competition between the ferrocene-hippuric acid complex and hippuric acid for binding to the anti-hippuric acid monoclonal antibody coated onto gold nanoparticles, the electrical signals are turned out to be proportional to urinary hippuric acid in the range of 0.01-10 mg/mL, which is enough to be used for the point-of-care. The proposed electrochemical method could extend its applications to detect a wide range of different small molecules of antigens in the health care area.
Keywords
Immunosensor; Hippuric acid; Ferrocene; Point-of-care;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 H. C. Yoon, M. Y. Hong, and H. S. Kim, ‘Functionalization of a poly(amidoamine) dendrimer with ferrocenyls and its application to the construction of a reagentless enzyme electrode’ Anal Chem., 72, 4420 (2000)   DOI
2 Young-Bong Choi and Hyug-Han Kim, ‘Synthesis of osmium redox complex and its application for biosensor using an electrochemical method’ Journal of the Korean Electrochemical Society., 10, 152 (2007).   과학기술학회마을   DOI
3 M. O. Finot, G. D. Braybrook, and M. T. McDermott, ‘Characterization of electrochemically deposited gold nanocrystals on glassy carbon electrodes’ J Electrochem Soc., 466, 234 (1999).
4 M. S. El-Deab, T. Okajima, and T. Ohsaka, ‘Electrochemical reduction of oxygen on gold nanoparticle-electrodeposited glassy carbon electrodes’ J Electrochem Soc., 150, A851 (2003).   DOI
5 C. Duan and M. E. Meyerhoff, ‘Immobilization of proteins on gold Coated Porous Membranes Via an Activated Self-Assembled Monolayer of Thioctic acid’ Anal Chem., 66, 1369 (1994).   DOI
6 T. J. Moore, M. J. Joseph, B. W. Allen, L. A, and Jr. Coury, ‘Enzymically Amplified Voltammetric Sensor for Microliter Sample Volumes of Salicylate’ Anal Chem., 67, 1896 (1995).   DOI
7 J. Wang, B. Tian, and K. R. Rogers, ‘Thick-film electrochemical immunosensor based on stripping potentiometric detection of a metal ion label’ Anal Chem., 70, 1682 (1998).   DOI
8 T. K. Lim and T. Matsunaga, ‘Construction of electrochemical flow immunoassay system using capillary columns and ferrocene conjugated immunoglobulin G for detection of human chorionic gonadotrophin’ Biosens Bioelectron, 16, 1063 (2001).   DOI
9 T. K. Lim, S. Imai, and T. Matsunaga, ‘Miniaturized amperometric flow immunoassay system using a glass fiber membrane modified with anion’ Biotechnol Bioeng., 77, 758 (2002).   DOI
10 T. K. Lim, H. Ohta, and T. Matsunaga, ‘Microfabricated On-Chip-Type Electrochemical Flow Immunoassay System for the Detection of Histamine Released in Whole Blood Samples’ Anal Chem., 75, 3316 (2003).   DOI
11 H. M. Park, S. H. Lee, H. Chung, O. H. Kwon, K. Y. Yoo, H. H. Kim, S. C. Heo, J. S. Park, and G. S. Tae, ‘Immunochromatographic analysis of hippuric acid in urine’ J Anal Toxicol., 31, 347 (2007).   DOI   ScienceOn
12 S. Purushothama, S. Kradtap, C. A. Wijayawardhana, H. B. Halsall, and W. R. Heineman, ‘Small Volume Bead Assay for Ovalbumin with Electrochemical Detection’ Analyst., 126, 337 (2001).   DOI
13 Y. Zhang and A. Heller, ‘Reduction of the nonspecific binding of a target antibody and of its enzyme-labeled detection probe enabling electrochemical immunoassay of an antibody through the 7 pg/ml-100 ng/mL (40 fM-400 pM) range’ Anal Chem., 77, 7758 (2005).   DOI
14 C. Padeste, A. Grubelnik, and L. Tiefenauer, ‘Ferroceneavidin conjugates for bioelectrochemical applications’ Biosens Bioelectron., 15, 431 (2000).   DOI
15 P. Kongtip, J. Vararussami, and V. Pruktharathikul, ‘Modified method for determination of hippuric acid and methylhippuric acid in urine by gas chromatography’ J Chromatogr B Biomed Sci Appl., 751, 199 (2001).   DOI
16 K. Tomokuni and M. Ogata, ‘Direct Colorimetric Determination of Hippuric Acid in Urine’ Clin Chem., 18, 349 (1972).
17 T. Sakai, Y. Niinuma, S. Yanagihara, and K. Ushio, ‘Simultaneous determination of hippuric acid and o-, mand p-methylhippuric acids in urine by high-performance liquid chromatography’ J Chromatogr., 276, 182 (1983).   DOI
18 A. C. Lee, G. Liu, C. K. Heng, S. N. Tan, T. M. Lim, and Y. Lin, ‘Sensitive electrochemical detection of horseradish peroxidase at disposable screen-printed carbon electrode’ Electroanalysis., 20, 2040 (2008).   DOI
19 Y. Y. Lin, J. Wang, G. Liu, H. Wu, C. M. Wai, and Y. Lin, ‘Label/immunochromatographic electrochemical biosensor for rapid and sensitive detection of prostate-specific antigen’ Biosensor and Bioelectronics., 23, 1659 (2008).   DOI
20 S. Prabhulkar, S. Alwarappan, G. Liu, and C. Z. Li, ‘Amperometric micro-immunosensor for the detection of tumor biomarker’ Biosensor and Bioelectronics., 24, 3524 (2009).   DOI
21 S. J. Yoo, Y. B. Choi, J. I. Ju, G. S. Tae, H. H. Kim and, S. H. Lee, ‘Microfluidic chip-based electrochemical immunoassay for hippuric acid’ Analyst., 134, 2462 (2009).   DOI
22 J. Wang, A. Ibanez, M. P. Chatrathi, and A. Escarpa, ‘Electrochemical enzyme immunoassays on microchip platforms’ Anal Chem., 73, 5323 (2001).   DOI
23 R. G. Feldman, M.H. Ratner, and T. Ptak, ‘Chronic toxic encephalopathy in a painter exposed to mixed solvents’ Environmental Health Perspectives., 107, 417 (1999).   DOI
24 J. W. Boor and H. I. Hutrig, ‘Permanent cerebellar ataxia after exposure to toluene’ Ann. Neurol., 2, 440 (1977).   DOI
25 N. L. Rosenberg, M. C. Spitz, C. M. Filley, K. A. Davis, and H. H Schaumburg, ‘Central nervous system effects of chronic toluene abuse-clinical, brainstem evoked response and magnetic -resonance imaging studies’ Neurotoxicol. Teratol., 10, 489 (1988).   DOI