The Electrochemical Studies of Two Osmium Redox Polymer Films and Their Application for Multi-Detecting Biosensor |
Tae, Gun-Sik
(Department of Biological Science, Dankook University)
Kim, Jin-Gu (Department of Chemistry, Dankook University) Choi, Young-Bong (Department of Chemistry, Dankook University) Kim, Hyug-Han (Department of Chemistry, Dankook University) |
1 | Y. Zhang, H-H. Kim, N. Mano, M. Dequaire, and A. Heller, 'Simple enzyme-amplified amperometric detection of a 38-base oligonucleotide at 20 pmol L-1 concentration in a 30-L droplet', Anal Bioanal Chem., 374, 1051 (2002) |
2 | Zakeeruddin, S. M.; D. M. Fraser, D. M.; Nazeeruddin, M.-K.; Gratzel, M. 'Towards mediator design: Characterization of tris-(4,4'-substituted-2,2'-bipyridine) complexes of iron(II), ruthenium(II) and osmium(II) as mediators for glucose oxidase of Aspergillus niger and other redox proteins' J. Electroanal. Chem. 337, 253 (1992) DOI ScienceOn |
3 | M. A. Lange and J. Q. Chambers, 'Amperometric determination of glucose with a ferrocene-mediated glucose oxidase/polyacrylamide gel electrode' Anal. Chim. Acta., 175, 89 (1985) DOI ScienceOn |
4 | A. P. F. Turner, 'Diabetes mellitus: biosensors for research and management' World Biotech. Rep., 1, 181 (1985) |
5 | P. D. Hale and T. A. Skotheim, 'Cyclic voltammetry at TCNQ and TTF-TCNQ modified platinum electrodes: A study of the glucose oxidase/glucose and galactose oxidase/ galactose systems' Synth. Met., 28, 853 (1989) DOI ScienceOn |
6 | B. A. Gregg and A. Heller, 'Redox polymer films containing enzymes. 2. Glucose oxidase containing enzyme electrodes' J. Phys. Chem., 95, 5976 (1991) DOI |
7 | R. M. Ianiello, T. J. Lindsay, and A. M. Yacynych, 'Differential pulse voltammetric study of direct electron transfer in glucose oxidase chemically modified graphite electrodes' Anal. Chem. 54, 1098 (1982) DOI |
8 | G. Kenausis, C. Taylor, R. Rajagopalan, and A. Heller, "Wiring" of glucose oxidase and lactate oxidase within a hydrogel made with poly(vinyl pyridine) complexed with [Os(4,4'-dimethoxy-2,2'- , J. Chem. Soc. Faraday Trans., 92, 4131 (1996) DOI |
9 | C. Taylor, G. Kenausis, I. Katakis, and A. Heller, "Wiring" of glucose oxidase within a hydrogel made with polyvinyl imidazole complexed with [(Os-4,4'-dimethoxy- 2,2'-bipyridine) , J. Electroanal. Chem., 396, 511 (1995) DOI ScienceOn |
10 | S. Anderson, E. C. Constable, K. R. Seddon, E. T. Turp, J. E. Baggott, and J. Pilling, 'Preparation and characterization of 2,2-bipyridine-4,4-disulphonic and-5-sulphonic acids and their ruthenium(II) complexes' J. Chem. Soc. Dalton Trans., 2247 (1985) |
11 | D. A. Gough, J. Y. Lucisano, and P. H. S. Tse, 'Twodimensional enzyme electrode sensor for glucose' Anal. Chem., 57, 2351 (1985) DOI ScienceOn |
12 | L. C. Clark Jr. and C. Lyons, 'Electrode systems for continuous monitoring in cardiovascular surgery' Ann. N.Y. Acad. Sci., 102, 29 (1962) DOI |
13 | M. S. Vreeke, K. T. Yong, and A. Heller, 'A Thermostable Hydrogen Peroxide Sensor Based on "Wiring" of Soybean Peroxidase' Anal. Chem., 67, 4247 (1995) DOI |
14 | O. Miyawaki and L. B. Wingard, Jr., 'Electrochemical and enzymatic activity of flavin adenine dinucleotide and glucose oxidase immobilized by adsorption on carbon' Biotech. Bioeng. 26, 1364 (1984) DOI ScienceOn |
15 | R. J. Forster and J. G. Vos, 'Synthesis, Characterization, and Properties of a Series of Osmium- and Ruthenium- Containing Metallopolymers' Macromolecule, 23, 4372 (1990) DOI |
16 | K. Mckenna and A. Brajter-Toth, 'Tetrathiofulvalene tetracyanoquinodimethane xanthine oxidase amperometric electrode for the determination of biological purines' Anal. Chem., 59, 954 (1987) DOI ScienceOn |
17 | A. L. Crumbliss, H. A. O Hill, and D. J. Page, 'The electrochemistry of hexacyanoruthenate at carbon electrodes and the use of ruthenium compounds as mediators in the glucose/glucose oxidase system' J. Electroanal. Chem. Interfacial Electrochem., 206, 327 (1986) DOI ScienceOn |