The humidification measurement system designed in laboratory was used to measure relative humidity and temperature of reaction gases passing through internal or external humidifier which was used in proton exchange membrane fuel cell test station. The relative humidity of gases was stabilized after $10\~20$ minutes and thus credibility of data could be assured. The effect of relative humidity on fuel cell performance could be analyzed by humidity measurement system. Extreme caution was needed to avoid humidity sensor mal-function or failure which is probable in experiment of high humidity condition near $100\%$. The amount of water carried by gas through humidifier was increased along the flow rate of gas. However, the extent of increase was lowered at high gas flow rate. These phenomena could be analyzed as residence time effect of gas in humidifier.
Keywords
Fuel cell; Humidity measurement; Energy efficiency;
Citations & Related Records
연도 인용수 순위
  • Reference
1 /
[ W. L. McCabe;J. C. Smith;P. Harriott ] / Unit operations of chemical engineering, (5th ed.)
2 Thermostable ionomeric filled membrane for H₂/O₂fuel cell /
[ B. Baradie;C. Poinsignon;J. Y. Sanchez;Y. Piffard;G. Vitter;N. Bestaoui;D. Foscallo;A. Denoyelle;D. Delabouglie;M. Vaujany ] / J. Power Sources   DOI   ScienceOn
3 Gas humidification process /
[ P. L. Reid;S. C. Dluncan ] / U. S. Patemt 4,759,882
4 Electrochemical fuel cell stack with humidification section located upstream from the electrochemically active section /
[ C. Y. Chow;B. W. Wozniczka ] / U. S. Patent 5,382,478
5 A study of internal humidification of an integrated PEMFC stack /
[ K. H. Choi;D. J. Park;Y. W. Rho;Y. T. Kho;T. H. Lee ] / J. Power Sources   DOI   ScienceOn
6 Effect of direct liquid water injection and interdigitated flow field on the performance of proton exchange membrane fuel cells /
[ D. L. Wood, Ⅲ;J. S. Yi;T. V. Nguyen ] / Electrochim. Acta   DOI   ScienceOn
7 Complex impedance measurements on nafion /
[ M. C. Wintergill;J. J. Fontanella ] / Electrochim. Acta   DOI   ScienceOn
8 Determination of water diffusion coefficients in perfluorosulfonate ionomeric membrane /
[ T. A. Zawodzinski;M. Neeman;L. O. Stillernd ] / J. Phys. Chem.