Browse > Article

A Study on Drainage Facilities in Mountainous Urban Neighborhood Parks - The Cases of Baebongsan Park and Ogeum Park in Seoul -  

Lee, Sang-Suk (Dept. of Landscape Architecture, University of Seoul)
Publication Information
Journal of the Korean Institute of Landscape Architecture / v.38, no.5, 2010 , pp. 80-92 More about this Journal
Abstract
The purpose of this study was to analyze drainage facilities in mountainous urban neigbborhood parks--Baebongsan Park and Ogeum Park--in Seoul. Based on an analysis of existing drainage facilities, the volume of storm water runoff (VSW), the runoff rate of open channels(ROC), and the detention capacity of open charmels(DCOC) by each drainage watershed, the coefficient of runoff rate(CROC) as evaluated to be relevant between VSW and ROC and the coefficient of the detention capacity of open channe1s(CDCOC) as evaluated with DCOC compared to VSW were estimated and analyzed by parks and by watersheds. The results are as follows: 1. The total drainage area of Baebongsan Park was 34.13ha including surface runoff area(15.05ha; 44.09%), open channel area(l4.60ha; 42.78%), and natural waterway area(4.48ha; 13.13%). The total drainage area of Ogeum Park was 20.39ha including open channel area (10.14ha; 49.73%), ridge-side gutter area(7.17ha; 35.16%), surface runoff area (2.52ha; 12.36%), and natural waterway area (0.56ha; 2.75%). In Baebongsan Park, the portion of surface runoff was comparatively higher while the portion of artificial drainage area was higber in Ogeum Park. 2. In Baebongsan Park drainage districts were largely divided: VSW was $7.28m^3/s$ in total(average $0.23m^3/s$). Comparatively, tbe VSW in Ogeum Park, including smaller drainage districts, was $4.37m^3/s$ in total(average $0.12m^3/s$). 3. The ROC of Baebmgsan Park was $11.58m^3/s$ in total(average $0.77m^3/s$) and the CROC was 5.26, while in Ogeum Park, the ROC was $15.40m^3/s$(average $0.34m^3/s$) and tbe CROC was 8.87 higher than that of Baebongsan Because the size and slope of the open channel in Baebongsan Park was higher, the average ROC was larger, while tbe CROC of Ogeum Park was higher than that of Baebongsan Park, for the VSW in Ogeum Park was comparatively lower. 4. The DCOC in Baebongsan Park was $554.54m^3$ and the average of CDCOC was 179.83. That of Ogeum Park was $717.74m^3$ and the average of the CDCOC was 339.69, meaning that the DCOC of Ogeum Park was so much higber that drainage facilities in Ogeum Park were built intensively. This study was focused m the capacity of the drainage facilities in mountainous urban neighborhood parks by using the CROC to evaluate relevance between VSW and ROC and the CDCOC to evaluate the DCOC as compared with VSW. The devised methodology and coefficient for evaluating drainage facilities in mountainous urban neighborhood parks may he universally applicable through additional study. Further study m sustainable urban drainage systems for retaining rainwater in a reservoir and for enhancing ecological value is required in the near future.
Keywords
Storm Water Runoff; Runoff Coefficient; Open Channel; Watershed; Sustainable Urban Drainage System;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Lal, A. M. W., Mark Belnap and Randy Van Zee(1998)Simulation of overland and groundwater flow in the Everglades National Park. Proceedings of the International Water Resources Engineering Conference. Memphis: rsmbiblio.bib: pp.610-615.
2 Johns, Philand Neil Macdonald(2006)Making space for unruly water : Sustainable drainage systems and the disciplining of surface runoff. Geoforum 38:534-544.
3 Kennedy, S., L. Lewis, E. Sharp and S. Wong(2007)Sustainable Urban Drainage Systems(SUDS)-More than adrainage solution?. Proceedings of the 6th International Conference on Suistainable Techniques and Strategies in Urban Water Management. Lyon:NOVATECH 2007.pp.423-430.
4 김지호,박영진,최인호,송재호(2004)산지유역의 합리식 유출계수 산정에 관한 연구.한국수자원학회 2004학술발표회논문집:173-177.
5 Chen, Jieyun and Barry J. Adams(2005)Analysis of storage facilities for urban stormwater quantity control. Advances in Water Resources 28:377-392.   DOI   ScienceOn
6 이해주,지병윤,정도현,김종윤,차두송(2000)임도 옆도랑의 침식요인 평가와 안정성 판별에 관한 연구.한국임학회지 89(3):397-404.
7 이호상,김기원,김철영(2004)임도의 횡단배수시설에 관한 연구.한국임학회 2004학술연구 발표논문집:325-327.
8 최기수,이상석(2003)조경구조학.서울:일조각.
9 환경부(2005)하수도시설기준.
10 농업과학기술원(2000)토양 및 식물체 분석법.
11 서울특별시(2009b)남산 물관리사업 기본 및 실시설계보고서.
12 서울특별시(2002)하수도정비기본계획(변경)보고서.
13 서울특별시(2007)미집행 도시계획시설 재정비계획 수립 90.
14 서울특별시(2009a)서울시 하수도정비기본계획(변경)보고서.
15 서울특별시,한국수자원학회(1999)98수해백서.
16 http://gis.seoul.go.kr/
17 강신권,김태균(2008)지역별 강우분포를 고려한 블록포장지역의 유출계수 산정에 관한 연구.한국조경학회지 36(4):111-119.   과학기술학회마을
18 국토해양부(2009)하천설계기준.
19 김영란(2004)서울시 침수피해 저감을 위한 우수저류시설 적용방안.서울시정개발연구원 보고서.
20 Storm, Steven, Kurt Nathan and Jake Woland(2008)Site Engineering for Landscape Architects (5nd ed.). New Jersey:John Wiley & Sons.
21 http://parks.seoul.go.kr/park/common/etc/park001.jsp
22 Molzahn, Robert E. and Christopher B. Burke(1986)Assessment of drainage infrastructure for urban areas.Tunnelling and Underground Space Technology 1(3/4): 387-389.   DOI