To collect or transfer samples of gaseous pollutants, various types of tubing are used. Hence, to analyze the uncertainties associated with the use of tubings, a series of comparative test were designed and conducted using the RSC standards with different concentration ranges. For the purpose of this study, we prepared tubings made of six different types of material which include: [1] silco-steel (S1), [2] stainless steel (S2), [3] silicone (S3), [4] PTFE Teflon (T1), [5] tygon (T2), and [6] brass (B). The patterns of RSC loss on to tubing walls, when compared on the basis of the least reactive material S1, exhibited that the extent of RSC loss varied dynamically. It was found that Teflon is highly stable. However, other materials tend to exhibit contrasting patterns of loss. S2 and B show significant loss of light RSC $(H_2S\;and\;CH_3SH)$, while S3 and T2 experience notable loss of heavy RSC (DMS and DMDS).
Keywords
Reduced Sulfur Compounds (RSC); adsorption; loss; tubing; Teflon;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김기현, 최여진 (2005) GC의 주입방식에 차에 따른 고농도 악취황 성분의 검량오차 연구: 주입부티의 고정방식 대비 주입농도의 고정방식 간 비교연구, 한국대기환경학회지, 21(2), 269-274
2 김기현, 최여진, 김성천 (2005) GC 분석시스템의 설정과 그에 따른 감도의 차이: 열탈착 방식 대비 루프주입방식에 의한 황성분의 분석, Analytical science & technology, 18(1), 66-73
3 Sulyok, M., Haberhauer-Troyer, C., and Rosenberg, E. (2002) Observation of sorptive losses of volatile sulfur compounds during natural gas sampling, Journal of chromatography A, 946, 301-305   DOI   PUBMED   ScienceOn
4 Kim K.-H. (2005b) Some insights into the gas chromatographic determination of reduced sulfur compunds (RSC) in air. Environ. Sci. & Technol. 39, 6765-6769   DOI   PUBMED   ScienceOn
5 김기현, 오상인, 최여진, 전의찬, 사재환, 선우영 (2004) 환원황 화합물을 중심으로 한 매립가스의 조성에 대한 연구, 한국대기환경학회지, 20(1), 77-85
6 Kim K.-H. (2005a) Performance characterization of the GC/PFPD for $H_2S,\;CH_3SH$, DMS, and DMDS in air. Atmospheric Environment 39, 2235-2242   DOI   ScienceOn
7 최여진, 김기현, 오상인, 손장호, 2004, 연속측정방법을 이용한 도심권 대기질 내 저농도 황화합물의 관측에 대한 연구, 한국대기환경학회지, 20(2), 195-204
8 Kim, K.-H., Choi, G.-H., Choi, Y.-J. and Song, H.N. (2005) the effects of sampling materials selection in the collection of reduced sulfur compounds in air. Talanta. In Press
9 전선주. 허귀석, 1999, 캐니스터와 Tedlar-bag 시료채집법을 이용한 대기 중의 휘발성유기화합물의 측정, 한국대기환경학회지, 15(4), 417-428
10 김기현, 임계규 (2004) 테들러 백을 이용한 대기 중 황성분의 채취: 보정인자의 적용을 위한 예비연구, 한국지구과학회지, 25(4), 265-269
11 Cheskis, S., Atar, E., and Amirav, A. (1993) Pulsed-flame photometer: a novel gas chromatography detector. Anal. Chem. 65, 539, 313-323   DOI