Browse > Article
http://dx.doi.org/10.5012/jkcs.2003.47.6.578

Static Supercritical Fluid Extraction of PCBs from Soil Matrix  

Ryoo, Keon-Sang (Department of Applied Chemistry, Andong National University)
Lee, Won-Kyoung (Department of Applied Chemistry, Andong National University)
Hong, Yong-Pyo (Department of Applied Chemistry, Andong National University)
Oh, In-Gyung (Department of Applied Chemistry, Andong National University)
Kim, Yong-Gyun (School of Bioresource Sciences, Andong National University)
Publication Information
Abstract
Polychlorinated biphenyls (PCBs) known as environmental contaminants in soil were analyzed by the soil pollution standard process test and the static supercritical $CO_2$ extraction mode. It was shown that the percent average recoveries of PCBs by the soil pollution standard process test were ranged in 25-35% and the corresponding standard deviations were above 10%. In contrast, the percent average recoveries of PCBs by the static supercritical $CO_2$ extraction mode were 2-2.5 times higher and standard deviations were within 7%. These results indicate that static supercritical $CO_2$ extraction mode may be a useful alternative to sample pretreatment certified by the soil pollution standard process test. The increasing supercritical $CO_2$ pressure from 1130 psi to 1996 psi at $40^{\circ}C$ enhanced the recovery of all PCB congeners from soil. However, at same Tc and Pc, the equilibrium time (5 versus 60 minutes) had no effect on the recovery of each PCB congener. Finally, similar PCB recoveries were obtained under the same extraction condition, regardless of the molecular weight and structure (coplanar versus non-coplanar) of PCB congeners.
Keywords
PCBs; Soil Pollution Standard Process Test; Static Supercritical Fluid Extraction Mode;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Safe, S. Critical Rev. Toxicology, 1990, 21, 51.   DOI
2 Gere, D. R.; Knipe, C. R.; Pipkin, W.; Randal, L. G. Int. Environ. Technology, 1995, 5(4), 20.
3 Safe, S. Annu. Rev. Pharmacal. Toxicol. 1986, 26, 371.   DOI   ScienceOn
4 Erickson, M. D. Analytical Chemistry of PCBs; CRC Press-Lewis Publishers: New York, U.S.A, 1997.
5 U. S. EPA Fed. Regist. 1979, 44, 31514.
6 Ross, R. A.; Lemay, R. Environ. Sci. Technol. 1987, 21, 1115.   DOI   ScienceOn
7 Iwata, H.; Tanabe, S.; Sakal, N.; Tatsukawa, R. Environ. Sci. Technol. 1993, 27, 1080.   DOI   ScienceOn
8 Anton, K.; Jan, P.; Stanislav, J.; Jana, C; Beata, D. Chemosphere, 2001, 43, 595.   DOI   ScienceOn
9 편집부저, 수질.폐기물.토양 공정시험방법; 동화기술, 2001.
10 Hawthome, S. B. Analytical Chemistry, 1990, 62, 633A   DOI
11 Yang, Y.; Hawthome, S. B.; Miller, D. J. J. Chramatogr. 1995, A699, 265.
12 Hawthome, S. B.; Langenfeld, J. J.; Miller, D. J.; Burford, M. D. Analytical Chemistry, 1992, 64, 1614.   DOI
13 Langenfeld, J. J.; Hawthome, S. B.; Miller, D. J.; Pawliszyn, J. Analytical Chemistry, 1994, 65, 338.   DOI