Browse > Article
http://dx.doi.org/10.5012/bkcs.2009.30.9.2021

Rapid HPLC Method for the Simultaneous Determination of Eight Urinary Metabolites of Toluene, Xylene and Styrene  

Lee, Cheol-Woo (Department of Pharmaceutical Analysis, College of Pharmacy, Chung-Ang University)
Lee, Jeong-Mi (Department of Pharmacology, University of Texas Southwestern Medical Center)
Lee, Jae-Hyun (Department of Pharmaceutical Analysis, College of Pharmacy, Chung-Ang University)
Eom, Han-Young (Department of Pharmaceutical Analysis, College of Pharmacy, Chung-Ang University)
Kim, Min-Kyung (Department of Pharmaceutical Analysis, College of Pharmacy, Chung-Ang University)
Suh, Joon-Hyuk (Department of Pharmaceutical Analysis, College of Pharmacy, Chung-Ang University)
Yeom, Hye-Sun (Department of Pharmaceutical Analysis, College of Pharmacy, Chung-Ang University)
Kim, Un-Yong (Department of Pharmaceutical Analysis, College of Pharmacy, Chung-Ang University)
Youm, Jeong-Rok (Department of Pharmaceutical Analysis, College of Pharmacy, Chung-Ang University)
Han, Sang-Beom (Department of Pharmaceutical Analysis, College of Pharmacy, Chung-Ang University)
Publication Information
Abstract
Toluene, xylene and styrene are volatile organic solvents that are commonly used in mixtures in many industries. Because these solvents are metabolized and then excreted in urine, their urinary metabolites are thought to be biomarkers of occupational exposure to these solvents. Therefore, a simple, rapid, and yet reliable analytical method for determining the metabolites is required for accurate biological monitoring. In the present study, a simple and rapid HPLC-UV method was developed for the simultaneous determination of eight major metabolites of toluene, xylene and styrene: hippuric acid (HA), mandelic acid (MA), o-, m- and p-methylhippuric acids (o-, m- and p-MHAs), and o-, m- and p-cresols. A monolithic column was employed as the stationary phase and several conditions, including flow rate, composition of mobile phase and column temperature, were variables for the optimization of the chromatographic resolution. All eight metabolites were successfully resolved within 5 minutes in 10% aqueous ethanol containing 0.3% acetic acid and 1.6% $\beta$-cyclodextrin, using a flow rate gradient of 1.0 - 5.0 mL/min at 25 ${^{\circ}C}$. The performance of this method was validated by linearity, intra- and inter-day accuracy, and precision. The linearity was observed with correlation coefficients of 0.9998 for HA, 0.9999 for MA, 0.9989 for o-MHA, 0.9998 for m-MHA, 0.9991 for p-MHA, 0.9997 for o-cresol, 0.9998 for m-cresol, and 0.9986 for p-cresol. The intra- and inter-day precision of the method were less than 5.89% (CV) and the accuracy ranged from 92.95 to 106.62%. The validity was further confirmed by analysis of reference samples that were prepared by the inter-laboratory quality assurance program of the Korea Occupational Safety and Health Agency (KOSHA, Seoul, Korea). All measured concentrations of the analytes agreed with the certified values.
Keywords
Urinary metabolites; HPLC-UV method; Monolithic column; $\beta$-Cyclodextrin; Flow rate gradient;
Citations & Related Records

Times Cited By Web Of Science : 1  (Related Records In Web of Science)
Times Cited By SCOPUS : 1
연도 인용수 순위
1 Deeb, S. E.; Schepers, U.; Wätzig, H. J. Sep. Sci. 2006, 29, 1571   DOI   ScienceOn
2 de Melo, N. F.; Grillo, R.; Rosa, A. H.; Fraceto, L. F. J. Pharm. Biomed. Anal. 2008, 47, 865   DOI   ScienceOn
3 Xiao, K. P.; Xiong, Y.; Rustum, A. M. J. Chromatogr. Sci. 2008, 46, 15   DOI   ScienceOn
4 Chen, D.; Jiang, S.; Chen, Y.; Hu, Y. J. Pharm. Biomed. Anal. 2004, 34, 239   DOI   ScienceOn
5 Laurens, J. B.; Mbianda, X. Y.; Spies, J. H.; Ubbink, J. B.; Vermaak, W. J. J. Chromatogr. B 2002, 774, 173   DOI   ScienceOn
6 Han, S. B.; Lee, S. J.; Lee, C. W.; Yoon, S. H.; Joung, S. K.; Youm, J. R. Anal. Sci. & Tech. 2006, 19, 433
7 Yang, J. S.; Lee, M. Y.; Park, I. J.; Moon, Y. H.; Kang, S. K. Int. Arch. Occup. Environ. Health 1997, 69, 361   DOI   ScienceOn
8 International Conference on Harmonization (ICH) of Technical Requirements for the Registration of Pharmaceuticals for Human Use; Validation of analytical procedures; ICH-Q2A: Geneva, 1995
9 Ogata, M.; Taguchi, T. Int. Arch. Occup. Environ. Health 1986, 58, 121   DOI
10 Poggi, G.; Giusiani, M.; Palagi, U.; Paggiaro, P. L.; Loi, A. M.; Dazzi, F.; Siclari, C.; Baschieri, L. Int. Arch. Occup. Environ. Health 1982, 50, 25   DOI
11 Arapitsas, P.; Turner, C. Talanta 2008, 74, 1218   DOI   ScienceOn
12 Liu, J.; Sun, J.; Zhang, W.; Gao, K.; He, Z. J. Pharm. Biomed. Anal. 2008, 46, 405   DOI   ScienceOn
13 Adcock, J. L.; Francis, P. S.; Agg, K. M.; Marshall, G. D.; Barnett, N. W. Anal. Chim. Acta 2007, 600, 136   DOI   ScienceOn
14 Lubda, D.; Cabrera, K.; Nakanishi, K.; Minakuchi, H. J. Sol-Gel Sci. Tech. 2002, 23, 185   DOI   ScienceOn
15 Tzanavaras, P. D.; Themelis, D. G. J. Pharm. Biomed. Anal. 2007, 43, 1526   DOI   ScienceOn
16 Yang, Y. D. Biomed. Chromatogr. 1998, 12, 47   DOI   ScienceOn
17 Kongtip, P.; Vararussami, J.; Pruktharathikul, V. J. Chromatogr. B 2001, 751, 199   DOI   ScienceOn
18 Chua, S. C.; Lee, B. L.; Liau, L. S.; Ong, C. N. J. Anal. Toxicol. 1993, 17, 129   DOI
19 Hansen, S. H.; D$\phi$ssing, M. J. Chromatogr. 1982, 229, 141   DOI   ScienceOn
20 Chakroun, R.; Faidi, F.; Hedhili, A.; Charbaji, K.; Nouaigui, H.; Laiba, M. B. J. Forensic. Sci. 2008, 53, 232   DOI   ScienceOn
21 Kataoka, H.; Manabe, K.; Nakase, S.; Makita, M. J. Pharm. Biomed. Anal. 1991, 9, 699   DOI   ScienceOn
22 Pacenti, M.; Dugheri, S.; Villanelli, F.; Bartolucci, G.; Calamai, L.; Boccalon, P.; Arcangeli, G.; Vecchione, F.; Alessi, P.; Kikic, I.; Cupelli, V. Biomed. hromatogr. 2008, 22, 1155   DOI   ScienceOn
23 Jiye, A.; Huang, Q.; Wang, G.; Zha, W.; Yan, B.; Ren, H.; Gu, S.; Zhang, Y.; Zhang, Q.; Shao, F.; Sheng, L. J. Anal. Biochem. 2008, 379, 20   DOI   ScienceOn
24 Marais, A. A.; Laurens, J. B. J. Sep. Sci. 2005, 28, 2526   DOI   ScienceOn
25 Szucs, S.; Toth, L.; Legoza, J.; Sarvary, A.; Adany, R. Arch. Toxicol. 2002, 76, 560   DOI   ScienceOn
26 Saito, T.; Takeichi, S. J. Pharm. Biomed. Anal. 2002, 30, 365   DOI   ScienceOn
27 Heinrich-Ramm, R.; Jakubowski, M.; Heinzow, B.; Christensen, J. M.; Olsen, E.; Hertel, O. Pure Appl. Chem. 2000, 72, 385   DOI   ScienceOn
28 Seedorff, L.; Olsen, E. Ann. Occup. Hyg. 1990, 34, 371   DOI   ScienceOn
29 Chen, Z.; Liu, S. J.; Cai, S. X.; Yao, Y. M.; Yin, H.; Ukai, H.; Uchida, Y.; Nakatsuka, H.; Watanabe, T.; Ikeda, M. Occup. Environ. Med. 1994, 51, 47   DOI   ScienceOn
30 Persson, B.; Fredriksson, M.; Olsen, K.; Boeryd, B.; Axelson, O. Cancer 1993, 72, 1773   DOI   ScienceOn
31 Imbriani, M.; Ghittori, S. Int. Arch. Occup. Environ. Health 2005, 78, 1   DOI   ScienceOn
32 Hee, S. Q. Biological Monitoring; an Introduction; Van Nostrand Reinhold: New York, U. S. A., 1993; p 471-478
33 Inoue, O.; Seiji, K.; Suzuki, T.; Watanabe, T.; Nakatsuka, H.; Satoh, H.; Ikeda, M. Bull. Environ. Contam. Toxicol. 1991, 47, 204   DOI   ScienceOn
34 Astier, A. J. Chromatogr. 1993, 643, 389   DOI   ScienceOn
35 Fujii, T.; Kawabe, S.; Horike, T.; Taguchi, T.; Ogata, M. J. Chromatogr. B 1999, 730, 41   DOI   ScienceOn