A Possible Merge of FRET and SPR Sensing System for Highly Accurate and Selective Immunosensing  

Lee, Jae-Beom (Department of Nanomedical Engineering, Pusan National University)
Chen, Hongxia (College of Life Science, Shanghai University)
Lee, Jae-Wook (Department of Nanomedical Engineering, Pusan National University)
Sun, Fangfang (Department of Nanomedical Engineering, Pusan National University)
Kim, Cheol-Min (School of Medicine, Pusan National University)
Chang, Chul-Hun L. (School of Medicine, Pusan National University)
Koh, Kwang-Nak (Department of Nanomedical Engineering, Pusan National University)
Publication Information
Abstract
Immuno-sensing for high accurate and selective sensing was performed by fluorescence spectroscopy and surface plasmon resonance (SPR), respectively. Engineered assembly of two fluorescent quantum dots (QDs) with bovine serum albumin (BSA) and anti-BSA was fabricated in PBS buffer for fluorescence analysis of fluorescence resonance energy transfer (FRET). Furthermore, the same bio-moieties were immobilized on Au plates for SPR analysis. Naturally-driven binding affinity of immuno-moieties induced FRET and plasmon resonance angle shift in the nanoscale sensing system. Interestingly, the sensing ranges were uniquely different in two systems: e.g., SPR spectroscopy was suitable for highly accurate analysis to measure in the range of 10$^{-15{\sim}-10$ng/mL while the QD fluorescent sensing system was relatively lower sensing ranges in 10$^{-10{\sim}-6$ng/mL. However, the QD sensing system was larger than the SPR sensing system in terms of sensing capacity per one specimen. It is, therefore, suggested that a mutual assistance of FRET and SPR combined sensing system would be a potentially promising candidate for high accuracy and reliable in situ sensing system of immune-related diseases.
Keywords
Immunosensor; FRET; SPR; Sensing system; Nanoparticle;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
Times Cited By Web Of Science : 1  (Related Records In Web of Science)
Times Cited By SCOPUS : 1
연도 인용수 순위
1 Gopel, W.; Heiduschka, P. Biosens. Bioelectron. 1995, 10, 853-883   DOI   ScienceOn
2 Turner, P. F. A.; Karube, I.; Wilson, G. S. Biosensors: Fundamentals and Applications; Oxford University Press: USA, 1987
3 Eggins, R. B. Chemical Sensors and Biosensors; Wiley: New York, 2002
4 Lei, C. X.; Gong, F. C.; Shen, G. L.; Yu, R. Q. Sensor Actuat B-Chem 2003, 96, 582-588   DOI   ScienceOn
5 Chen, H. X.; Kim, Y. S.; Keum, S. R.; Kim, S. H.; Choi, H. J.; Lee, J. B.; An, W. G.; Koh, K. Sensors 2007, 7, 1216-1223   DOI
6 Lyon, L. A.; Musick, M. D.; Natan, M. J. Anal. Chem. 1998, 70, 5177-5183   DOI   ScienceOn
7 Wilson, M. S. Anal. Chem. 2005, 77, 1496-1502   DOI   ScienceOn
8 Wang, J. Electroanalysis 2005, 17, 7-14   DOI   ScienceOn
9 Balasubramanian, K.; Burghard, M. Anal. Bioanal. Chem. 2006, 385, 452-468   DOI   ScienceOn
10 Park, J. K.; Yee, H. J.; Lee, K. S.; Lee, W. Y.; Shin, M. C.; Kim, T. H.; Kim, S. R. Anal. Chim. Acta 1999, 390, 83-91   DOI   ScienceOn
11 Svorc, J.; Miertus, S.; Katrlik, J.; Stredansky, M. Anal. Chem. 1997, 69, 2086-2090   DOI   ScienceOn
12 R, S. S. Biosens. Bioelectron 1994, 9, 243-264   DOI   ScienceOn
13 Lee, S. M.; Lee, W. Y. Bull. Korean Chem. Soc. 2002, 23, 1169-1172   과학기술학회마을   DOI   ScienceOn
14 Pejcic, B.; De Marco, R.; Parkinson, G. Analyst 2006, 131, 1079-1090   DOI   ScienceOn
15 Mark, R. H.; Ebtisam, W. Am. J. Appl. Sci. 2005, 2, 796-805   DOI
16 Gaponik, N.; Talapin, D. V.; Rogach, A. L.; Hoppe, K.; Shevchenko, E. V.; Kornowski, A.; Eychmueller, A.; Weller, H. J. Phys. Chem. B 2002, 106, 7177-7185   DOI   ScienceOn
17 Lee, J. B.; Govorov, A. O.; Dulka, J.; Kotov, N. A. Nano Lett. 2004, 4, 2323-2330   DOI   ScienceOn