Browse > Article
http://dx.doi.org/10.5012/bkcs.2003.24.9.1319

Quantitative Analysis of Seven Triazine Herbicides by On-Line Micellar Electrokinetic Chromatography-Electrospray Ionization Mass Spectrometry  

Kang, Seong-Ho (Department of Chemistry, Chonbuk National University)
Shin, Dae-Ho (Korea Basic Science Institute)
Chang, Yoon-Seok (School of Environment Science and Engineering, Pohang University of Science and Technology)
Publication Information
Abstract
This paper presents a successful demonstration of the on-line coupling of MEKC (micellar electrokinetic chromatography) to ESIMS (electrospray ionization mass spectrometry) for the quantitative analysis of seven s-triazine herbicides. The on-line MEKC-ESIMS was used to determine the structure of CE-separated peaks of seven triazine herbicides. The mixture of triazine herbicides was separated in a 20 mM sodium borate buffer (pH 8.5) containing 15 mM sodium dodecylsulfate (SDS) by using a bare fused-silica capillary. Electrospray ionization mass spectrometer was operated in the positive-ion mode when the mass spectra of seven triazine herbicides were observed from each peak, and the solution of water-methanol-formic acid (50/49/1 v/v/v) was used as a sheath liquid. The effects of SDS concentration, the run buffer pH, and the electric field on the separation of seven s-triazine herbicides were investigated. The MEKC-ESIMS detection showed 5 to 10 times higher sensitivity compared to the MEKC-UV detection. In addition, it did not need any pretreatment step.
Keywords
Triazines; On-line MEKC-ESIMS;
Citations & Related Records

Times Cited By Web Of Science : 2  (Related Records In Web of Science)
Times Cited By SCOPUS : 2
연도 인용수 순위
1 Terabe, S.; Otsuka, K.; Ichikawa, K.; Tsuchiya, A.; Ando, T. Anal.Chem. 1984, 56, 111.   DOI
2 Baker, D. R. Capillary Electrophoresis; A Wiley-IntersciencePublication: New York, U. S. A., 1995; p 58.
3 Moseley, M. A.; Deterding, L. J.; Tomer, K. B.; Jorgenson, J. W. J.Chromatogr. 1990, 516, 167.   DOI   ScienceOn
4 Schmitt, P.; Garrison, A. W.; Freitag, D.; Kettrup, A. J. Chromatogr.A 1996, 723, 169.   DOI   ScienceOn
5 Cohen, A. S.; Paulus, A.; Karger, B. L. Chromatogrphia 1987, 24,15.   DOI
6 Moseley, M. A.; Jorgenson, J. W.; Shabanowitz, J.; Hunt, D. F.;Tomer, K. B. J. Am. Soc. Mass Spectrum 1992, 3, 289.   DOI   ScienceOn
7 Foret, F.; Bocek, P. In Advances in Electrophoresis; Chrambach,A.; Dunn, M. J.; Radola, B. J., Eds.; VCH: Weinheim, 1989; p273.
8 Pleasance, S.; Thibault, P.; Kelly, J. J. Chromatogr. 1992, 59, 325.
9 Hopfgartner, G.; Wachs, T.; Bean, K.; Henion, J. Anal. Chem.1993, 65, 439.   DOI
10 Baker, D. R. Capillary Electrophoresis; A Wiley-IntersciencePublication: New York, U. S. A., 1995; p 26.
11 Schmitt, Ph.; Poiger, T.; Simon, R.; Freitag, D.; Kettrup, A.;Garrison, A. W. Anal. Chem. 1997, 69, 2559.   DOI   ScienceOn
12 Foret, F.; Sustac, V.; Bocek, P. Electrophoresis 1990, 11, 95.   DOI   ScienceOn
13 Carabias-Martinez, R.; Rodriguez-Gonzalo, E.; Dominguez-Alvarez,J.; Hernandez-Mendez, J. J. Chromatogr. A 2000, 869, 451.   DOI   ScienceOn
14 Carabias-Martinez, R.; Rodriguez-Gonzalo, E.; Dominguez-Alvarez, J.; Hernandez-Mendez, J. Anal. Chem. 1999, 71, 2468.   DOI   ScienceOn
15 Carabias-Martinez, R.; Rodriguez-Gonzalo, E.; Dominguez-Alvarez, J.; Hernandez-Mendez, J. Anal. Chem. 1997, 69, 4437.   DOI   ScienceOn
16 Matchett, W. H.; Winnik, W.; Brumley, W. C. J. Cap. Elec. 1996,3, 199.
17 Cai, J.; Rassi, Z. E. J. Chromatogr. 1992, 608, 31.   DOI   ScienceOn
18 Moseley, M. A.; Deterding, L. J.; Tomer, K. B.; Jorgenson, J. W.Anal. Chem. 1991, 63, 109.   DOI   ScienceOn
19 Carabias-Martinez, R.; Rodriguez-Gonzalo, E.; Dominguez-Alvarez, J.; Hernandez-Mendez, J. Electrophoresis 2002, 23, 494.   DOI   ScienceOn
20 Jun, S.; Yoshihisa, U.; Akihiro, K.; Ikuroshin, K. Anal. Biochem.1992, 207, 1.   DOI   ScienceOn
21 Yang, L.; Harrata, A. K.; Lee, C. S. Anal. Chem. 1997, 69, 1820.   DOI   ScienceOn
22 Smith, R. D.; Olivares, J. A.; Nguyen, N. T.; Udseth, H. R. Anal.Chem. 1998, 60, 426.