QCM biosensor for the determination of haptoglobin
![]() |
Kim, Sung-Il
(Department of Chemistry, Kangnung National University)
Lee, Hyeon-Jeong (Gangwon Science High School) Park, Soon-Hyuk (Gangwon Science High School) Bhang, Hyun-Soo (Gangwon Science High School) Lee, Jin-Ah (Gangwon Science High School) Choi, Suk-Jung (Department of Chemistry, Kangnung National University) |
1 | L. Pastorino, F. Caneva Soumetz, M. Giacomini, and C. Ruggiero, 'Development of a piezoelectric immunosensor for the measurement of paclitaxel', J. lmmunol. Methods, vol. 313, pp. 191-198, 2006 DOI ScienceOn |
2 | U. Gronlund, C. H. Sandgren, and K. P. Waller, 'Haptoglobin and serum amyloid A in milk from dairy cows with chronic sub-clinical mastitis', Vet. Res., vol. 36, pp. 191-198, 2005 DOI ScienceOn |
3 | B. Ye, D. W. Cramer, S. J. Skates, S. P. Gygi, V. Pratomo, L. Fu, N. K. Horick, L. J. Licklider, J. O. Schorge, R. S. Berkowitz, and S. C. Mok, 'Haptoglobin-alpha subunit as potential serum biomarker in ovarian cancer: identification and characterization using proteomic profiling and mass spectrometry', Clin. Cancer. Res., vol. 9, pp. 2904-2911, 2003 |
4 | P. D. Eckersall and J. G. Conner, 'Plasma haptoglobin in cattle (Bos taurus) exists as polymers in association with albumin', Comp. Biochem. Physiol. B, vol. 96, pp. 309-314, 1990 DOI ScienceOn |
5 | N. K. Chaki and K. Vijayamohanan, 'Self-assembled mono layers as a tunable platform for biosensor applications', Biosens. Bioelectron., vol. 17, pp. 112, 2002 |
6 | C. Kumar, Nanosystem Characterization Tools in the Life Sciences, Wiley-VCH, Weinheim, Germany, pp. 109-144, 2006 |
7 | Y. S. Fung and Y. Y. Wong, 'Self-assembled monolayers as the coating in a quartz piezoelectric crystal immunosensor to detect Salmonella in aqueous solution', Anal. Chem., vol. 73, pp. 5302-5309, 2001 DOI ScienceOn |
8 | S. Y. Kwon, J. C. Kim, and B. I. Choi, 'Development of QCM dew point sensor and its sensing characteristics study', J. of the Korean Sensors Society, vol. 15, pp. 269-276, 2006 과학기술학회마을 DOI |
9 | H. H. Petersen, J. P. Nielsen, and P. M. Heegaard, 'Application of acute phase protein measurements in veterinary clinical chemistry', Vet. Res., vol. 35, pp. 163-187, 2004 DOI ScienceOn |
10 | S. C. Tam and J. T. Wong, 'Modification of hemoglobin upon covalent coupling to dextran: enhanced stability against acid denaturation and reduced affinity for haptoglobin', Can. J. Biochem., vol. 58, pp. 732-736, 1980 DOI |
11 | T. Okazaki, Y. Yanagisawa, and T. Nagai, 'Analysis of the affinity of each haptoglobin polymer for hemoglobin by two-dimensional affinity electrophoresis', Clin. Chim. Acta., vol. 258, pp. 137-144, 1997 DOI ScienceOn |
12 | M. Morimatsu, B. Syuto, N. Shimada, T. Fujinaga, S. Yamamoto, M. Saito, and M. Naiki, 'Isolation and characterization of bovine haptoglobin from acute phase sera', J. BioI. Chem., vol. 266, pp. 11833-11837, 1991 |
13 | M. Kotaka, G. G. Chen, P. B. Lai, W. Y. Lau, P. K. Chan, T. W. Leung, and A. K. Li, 'Analysis of differentially expressed genes in hepatocellular carcinoma with hepatitis C virus by suppression subtractive hybridization', Oncol. Res., vol. 13, pp. 161-167, 2002 |
14 | H. Van Vlierberghea, M. Langloisb, and J. Delanghe, 'Haptoglobin polymorphisms and iron homeostasis in health and in disease', Clin. Chim. Acta, vol. 345, pp. 35-42, 2004 DOI ScienceOn |
15 | X. Su, F. T. Chew, and S. F. Li. 'Self-assembled monolayer-based piezoelectric crystal immunosensor for the quantification of total human immunoglobulin E', Anal. Biochem., vol. 273, pp. 66-72, 1999 DOI ScienceOn |
16 | V. B. Kandimalla, N. S. Neeta, N. G. Karanth, M. S. Thakur, K. R. Roshini, B. E. Rani, A. Pasha, and N. G. Karanth, 'Regeneration of ethyl parathion antibodies for repeated use in immunosensor: a study on dissociation of antigens from antibodies', Biosens. Bioelectron., vol. 20, pp. 903-906, 2004 DOI ScienceOn |
17 | Y. Kaneta, Y. Kagami, T. Tsunoda, R. Ohno, Y. Nakamura, and T. Katagiri, 'Genome-wide analysis of gene-expression profiles in chronic myeloid leukemia cells using a cDNA microarray', Int. J. Oncol., vol. 23, pp. 681-691, 2003 |
18 | H. F. Juan, J. H. Chen, W. T. Hsu, S. C. Huang, S. T. Chen, J. Y.-C. Lin, Y. W. Chang, C. Y. Chiang, L. L. Wen, D. C. Chan, Y. C. Liu, and Y. J. Chen, 'Identification of tumor-associated plasma biomarkers using proteomic techniques: From mouse to human', Proteomies, vol. 4, pp. 2766-2775, 2004 DOI ScienceOn |
19 | M. Akerstedt, L. Bjorck, K. P. Waller, and A. Stemesjo, 'Biosensor assay for determination of haptoglobin in bovine milk', J. Daily Res., vol. 73, pp. 299-305, 2006 |
20 | A. J. Eun, L. Huang, F. T. Chew, S. F. Li, and S. M. Wong, 'Detection of two orchid viruses using quartz crystal microbalance (QCM) immunosensors', J. Virol. Methods, vol. 99, pp. 71-79, 2002 DOI ScienceOn |
21 | X. L. Su and Y. Li, 'A self-assembled monolayerbased piezoelectric immunosensor for rapid detection of Escherichia coli 0157:H7', Biosens. Bioelectron., vol. 19, pp. 563-574, 2004 DOI ScienceOn |
22 | S. F. Chou, W. L. Hsu, J. M. Hwang, and C. Y. Chen, 'Determination of alpha-fetoprotein in human serum by a quartz crystal microbalance-based immunosensor', Clin. Chem., vol. 48, pp. 913-918, 2002 |
23 | M. M. Vareiro, J. Liu, W. Knoll, K. Zak, D. Williams, and A. T. Jenkins, 'Surface plasmon fluorescence measurements of human chorionic gonadotrophin: role of antibody orientation in obtaining enhanced sensitivity and limit of detection', Anal. Chem., vol. 77, pp. 2426-2431, 2005 DOI ScienceOn |
![]() |