Browse > Article
http://dx.doi.org/10.5668/JEHS.2022.48.6.324

Affecting Factors of Lung Disease and Classification of Exposure Rating of Applicants for Injuries from Humidifier Disinfectants  

Gihong, Min (Department of Health and Safety, Daegu Catholic University)
Junghyun, Shin (Korea Society of Environment Health)
Eun-Kyung, Jo (Korea Society of Environment Health)
Dayoung, Jeong (Korea Society of Environment Health)
Jiyoon, Ryu (Korea Society of Environment Health)
Dongjun, Kim (Department of Health and Safety, Daegu Catholic University)
Jaemin, Woo (Department of Health and Safety, Daegu Catholic University)
Sungho, Bae (Department of Health and Safety, Daegu Catholic University)
Jihun, Shin (Department of Health and Safety, Daegu Catholic University)
Seula, Lee (Department of Preventive Medicine, Gachon University College of Medicine)
Yoon-Hyeong, Choi (Department of Preventive Medicine, Gachon University College of Medicine)
Wonho, Yang (Department of Health and Safety, Daegu Catholic University)
Publication Information
Journal of Environmental Health Sciences / v.48, no.6, 2022 , pp. 324-330 More about this Journal
Abstract
Background: Lung injuries due to exposure to humidifier disinfectants (HDs) were reported in 2011 in South Korea. As a result of the government's epidemiological investigation and toxicity test study, it was found that HDs caused health damage such as lung disease. Objectives: The purpose of this study was to classify HD exposure ratings and analyze the affecting factors that could identify the relationship with lung disease. Methods: Exposure assessment for HDs was conducted using a questionnaire during face-to-face interviews with the applicants. Ratings of high exposure (Class 1) and low exposure (Class 2) were cross-tabulated with clinical ratings (acceptable and unacceptable). Logistic regression analysis was carried out by setting the clinical rating of lung disease as a dependent variable and the socio-demographic and exposure characteristics obtained through the questionnaire as independent variables. Results: The concentration in air of polyhexamethylene guanidine (PHMG) was 71.96±107.47 ㎍/m3, and the exposure concentration was 15.21±23.28 ㎍/m3 . The exposure rating was overestimated with 97.1% of affected subjects having high exposure using margin of exposure (MOE), but only 9.9% matching the clinical class. In the overestimated group, it could be explained by the fact that the exposure time was long and the subjects had already recovered from damage symptoms. As a result of logistic regression analysis, ten variables were found to be significant influencing factors. Conclusions: A new exposure rating could be calculated based on the MOE, and factors affecting lung disease could be estimated through comparative evaluation with the clinical rating.
Keywords
Humidifier disinfectant; exposure rating; margin of exposure; lung disease;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 United States Environmental Protection Agency (U.S. EPA). Risk Assessment Guidance for Superfund Volume I: Human Health Evaluation Manual (Part F, Supplemental Guidance for Inhalation Risk Assessment). Washington, D.C.: EPA; 2009.
2 Shim HE, Lee JY, Lee CH, Mushtaq S, Song HY, Song L, et al. Quantification of inhaled aerosol particles composed of toxic household disinfectant using radioanalytical method. Chemosphere. 2018; 207: 649-654.   DOI
3 Delgado-Rodriguez M, Llorca J. Bias. J Epidemiol Community Health. 2004; 58(8): 635-641.   DOI
4 Paek D, Koh Y, Park DU, Cheong HK, Do KH, Lim CM, et al. Nationwide study of humidifier disinfectant lung injury in South Korea, 1994-2011. Incidence and dose-response relationships. Ann Am Thorac Soc. 2015; 12(12): 1813-1821.   DOI
5 Park K. An analysis of a humidifier disinfectant case from a toxicological perspective. Environ Health Toxicol. 2016; 31: e2016013.   DOI
6 Park D, Ryu S, Lim H, Kim S, Roh H, Cha W, et al. Estimation of humidifier disinfectant amounts inhaled into the respiratory system. J Environ Health Sci. 2016; 42(3): 141-146.   DOI
7 Vahtera J, Kivimaki M, Vaananen A, Linna A, Pentti J, Helenius H, et al. Sex differences in health effects of family death or illness: are women more vulnerable than men? Psychosom Med. 2006; 68(2): 283-291.   DOI
8 Read JG, Gorman BK. Gender and health inequality. Annu Rev Sociol. 2010; 36: 371-386.
9 Choi Y, Lim H, Lim S, Paek D. Health damages and lessons of the use of humidifier disinfectants in Korea. J Environ Health Sci. 2012: 38(2): 166-174.   DOI
10 Kim E, Ryu H, Park J, Choe Y, Heo J, Lee S, et al. Classification and characterization of exposure rating in humidifier disinfectants through calculation of PHMG reference concentration. J Environ Health Sci. 2020; 46(3): 335-343.
11 Quinn A, Shaman J. Indoor temperature and humidity in New York City apartments during winter. Sci Total Environ. 2017; 583: 29-35.   DOI
12 Yoon C, Kim S, Kim Y, Park M. Assessment of hazardous substances concentration in the air according to the type of water used in the humidifier. Korean J Public Health. 2019; 56(1): 33-39.   DOI
13 Ryu H, Choi YH, Kim E, Park J, Lee S, Yoon J, et al. Misclassification and characterization of exposure to humidifier disinfectants using a questionnaire. BMC Public Health. 2021; 21(1): 1458.   DOI
14 Daftary AS, Deterding RR. Inhalational lung injury associated with humidifier "white dust". Pediatrics. 2011; 127(2): e509-e512.   DOI
15 Lee H, Byeon S, Lee K. Recommendation of occupational exposure limit through occupational hazard assessment of PHMG-phosphate. J Korean Soc Occup Environ Hyg. 2019; 29(1): 13-20.   DOI
16 Ryu SH, Park DU, Lee E, Park S, Lee SY, Jung S, et al. Humidifier disinfectant and use characteristics associated with lung injury in Korea. Indoor Air. 2019; 29(5): 735-747.   DOI
17 Korea Centers for Disease Control and Prevention (KCDC). Analytical Results of the Chemical Components of Various Humidifier Disinfectant Brands from KCDC's Parliamentary Inspection. Cheongju: KCDC; 2011.
18 Korean Society of Environmental Health (KSEH). Case Studies on Victims of Humidifier Disinfectants. Seoul: Korean Society of Environmental Health; 2012.
19 Kim J, Zoh K, Kim H, Park D. A review on the health risks associated with the use of products containing benzalkonium chloride (BKC), focusing on humidifier disinfectant products. J Environ Health Sci. 2021; 47(6): 513-520.
20 National Institute of Environmental Research (NIER). Establishing Disease Identification and Standards Criteria to Expand the Range of Health Hazards Caused by the Humidifier Sterilizer. Incheon: National Institute of Environmental Research; 2017.
21 Ministry of Environment (MoE). 2017 White Paper of Environment. Sejong: Ministry of Environment; 2017.
22 Korea Environmental Industry and Technology Institute (KEITI). Statistical Data. Available: https://www.healthrelief.or.kr/home/content/stats01/view.do [accessed 2 December 2022].
23 Choi Y, Ryu H, Yoon J, Lee S, Kwak J, Han B, et al. Demographic characteristics and exposure assessment for applicants who have been injured by humidifier disinfectant- focusing on 4-1 and 4-2 applicants. J Environ Health Sci. 2018; 44(4): 301-314.
24 Kim EC. Analysis of affecting factors of lung disease according to exposure and socio-demographic characteristics in the affected victims by usage of humidifier disinfectants [dissertation]. [Gyeongsan]: Daegu Catholic University; 2021.
25 National Institute of Environmental Research (NIER). A Safety Study for Management of the Existing Chemicals (I). Incheon: National Institute of Environmental Research; 2013.
26 Nieuwenhuijsen MJ. Exposure assessment in occupational and environmental epidemiology. Oxford: Oxford University Press; 2003.
27 Kim S. Assessment of factors affecting the exposure on local community [dissertation]. [Gyeongsan]: Daegu Catholic University; 2014.
28 Manini P, De Palma G, Mutti A. Exposure assessment at the workplace: implications of biological variability. Toxicol Lett. 2007; 168(3): 210-218.   DOI
29 Korea Occupational Safety and Health Agency (KOSHA). Chemical Information. Available: http://msds.kosha.or.kr/kcic/msdssearchAll.do [accessed 2 December 2022].
30 Park J, Ryu H, Heo J, Cho M, Yang W. Estimation of ventilation rates in Korean homes using time-activity patterns and carbon dioxide (CO2) concentration. J Environ Health Sci. 2019; 45(1): 1-8.
31 Yang W, Lee K, Chung M. Characterization of indoor air quality using multiple measurements of nitrogen dioxide. Indoor Air. 2004; 14(2): 105-111.   DOI
32 Diapouli E, Chaloulakou A, Koutrakis P. Estimating the concentration of indoor particles of outdoor origin: a review. J Air Waste Manag Assoc. 2013; 63(10): 1113-1129.   DOI
33 Yao W, Dal Porto R, Gallagher DL, Dietrich AM. Human exposure to particles at the air-water interface: influence of water quality on indoor air quality from use of ultrasonic humidifiers. Environ Int. 2020; 143: 105902.   DOI