Browse > Article

A Case Report on Fungal Contamination and Remediation in a Leakage-water Damaged Apartment  

Cho, Jun-Ho (Management Center for Health Promotion, Korea Institute for Health and Social Affairs)
Paik, Nam-Won (International Environmental Consultants)
Publication Information
Journal of Environmental Health Sciences / v.32, no.5, 2006 , pp. 418-423 More about this Journal
Keywords
water-leakage; apartment; fungi; ozone treatment; biocide;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Hong, J. B., Chung, Y. H. and Chang, Y. H. : Distribution of hospital airborne microorganisms in Seoul, Korea. Korean Journal Environmental Health Society, 29(1), 1-7, 2003   DOI   ScienceOn
2 Bae SoonSuk : Study on the housing warranty system for consumer protection. Housing Studies Review, 13(3), 5-32, 2005
3 The Genus Aspergillus : Raper, K. B., Fennel, D. I., The William & Wilkins Co., Baltimore, 1965
4 Indoor Air Quality Standard 95-1 recommended for Florida. : Indoor Air Quality Association, Inc., Longwood, Florida, 1995
5 Sampling Instrumentation and Methods : United States Occupational Safety and Health Administration (USOSHA) OSHA Technical Manual, Washington, D.C., OSHA, 1992
6 Elford, W. J. and van den Ende, J. : An investigation of the merits of ozone as an aerial disinfectant. Journal of Hygiene, 42, 240-265, 1942   DOI
7 Rautiala, S., Reponen, T., Nevalainen, A., Husman, T. and Kalliokoski, P. : Control of exposure to airborne viable microorganisms during remediation of moldy buildings; report of three case studies. American Industrial Hygiene Association Journal, 59, 455-460, 1998   DOI
8 Moon, K. W., Byeon, S. H., Choi, D. W., Kim, Y. W., Lee, J. H. and Lee, E. I. : Exposure assessments on biological contaminants in homes of allergy patients-bacteria, fungi, house dust mite allergen and endotoxin. Korean Journal Environmental Health Society, 31(2), 120-126, 2005   과학기술학회마을
9 Bio-aerosols: Assessment and Control : Macher, J. (Ed.) American Conference of Governmental Industrial Hygienists, Cincinnati, OH, 1999
10 Donham, K., Haglind, P., Peterson, Y., Rylander, R. and Belin, L. : Environmental and health studies of farm workers in Swedish swine confinement buildings. British Journal of Industrial Medicine, 46, 31-37, 1989
11 Population and Housing Census Report 2005 : Korea National Statistical Office (KNSO), 2006
12 Reynolds, S. J., Streifel, A. J. and McJilton, C. E. : Elevated airborne concentrations of fungi in residential and office environments. American Industrial Hygiene Association Journal, 51, 601-604, 1990   DOI
13 Field Guide for the Determination of Biological Contaminants in Environmental Samples : Dillon, H. K., Heinsohn, P. A. and Miller, J. D. (eds), American Industrial Hygiene Association, Fairfax, 119-121, 1996
14 Manual and Atlas of the Penicillia : Ramirez, C., Elsevier Biomedical, Amsterdam, 1982
15 NIOSH Manual of Analytical Methods, J. : National Institute for Occupational Safety and Health, 91, 1998
16 Cho, J. H., Min, K. H. and Paik, N. W. : Temporal variation of airborne fungi concentrations and related factors in subway stations in Seoul, Korea. International Journal of Hygiene and Environmental Health, 209(3), 249-255, 2006   DOI   ScienceOn
17 Kim, Y. S., Lee, E. G., Yup, M. J. and Kim, K. Y. : Distribution and classification of indoor concentration of microorganisms in public buildings. Korean Journal Environmental Health Society, 28(1), 85-92, 2002   DOI   ScienceOn
18 Foarde, K., van Osdell, D. and Steiber, R. : Investigation of gas-phase ozone as a potential biocide. Applied Occupational Environmental Hygiene, 12(8), 535-542, 1997   DOI   ScienceOn