Comparison of Algorithms for Generating Parametric Image of Cerebral Blood Flow Using PET Positron Emission Tomography |
Lee, Jae-Sung
(Department of Nuclear Medicinel, Seoul National University College of Medicine)
Lee, Dong-Soo (Department of Nuclear Medicinel, Seoul National University College of Medicine) Park, Kwang-Suk (Department of Nuclear Medicinel, Seoul National University College of Medicine) Chung, June-Key (Department of Nuclear Medicinel, Seoul National University College of Medicine) Lee, Myung-Chul (Department of Nuclear Medicinel, Seoul National University College of Medicine) |
1 | Kety SS. The theory and application of the exchange inert gas at the lung and tissues. Pharmacol Rev. 1951;3: 1-41 PUBMED |
2 | Feng D,Wang Z, Huang S-C. A study on statistically reliable and computationally efficient algorithms forgenerating local cerebral blood flow parametric images with positron emission tomography. IEEE Trans Med Imaging. 1993;12:182-188 DOI ScienceOn |
3 | Alpert NM, Eriksson L, Chang JY, et al. Strategy for the measurement of regional cerebral blood flow using short-lived tracers and emission tomography. J Cereb Blood Flow Metab. 1984;4: 28-34 DOI PUBMED |
4 | Yokoi T, Kanno I, Iida H, Miura S, Uemura K. A new approach of weighted integration technique based on accumulated images using dynamic PET and HO. J Cereb Blood Flow Metab. 1991;11:492-501 DOI PUBMED |
5 | Zubal IG, Harrell CR, Smith EO, Rattner Z, Gindi G, Hoffer PB. Computerized 3-dimensional segmented human anatomy. Med Phys. 1994;21:299-302 DOI ScienceOn |
6 | Iida H, Miura S, Shoji Y, et al. Noninvasive quantitation of cerebral blood flow using oxygen-15-water and a dual-PET system. J Nucl Med. 1998;39: 1789-1798 PUBMED |
7 | Iida H, Rhodes CG, de Silva R, et al. Use of the left ventricular time-activity curve as a noninvasive input function in dynamic oxygen-15-water positron emission tomography. J Nucl Med.1992;33: 1669-1677 PUBMED |
8 | Koeppe RA, Holthoff VA, Frey KA, Kilbourn MR, Kuhl DE. Compartmental analysis of [11C]flumazenil kinetics for the estimation of ligand transport rate and receptor distribution using positron emission tomography. J Cereb Blood Flow Metab. 1991;11: 735-744 DOI PUBMED |
9 | Thompson CJ, Moreno-Cantu J, Picard Y. PETSIM: Monte Carlo Simulation of all Sensitivity and Resolution Parameters of Positron Imaging Systems. Phys Med Biol. 1992;37: 731-749 DOI ScienceOn |
10 | Kimura Y, Senda M, Alpert NM. Fast formation of statistically reliable FDG parametric images based on clustering and principal components. Phys Med Biol. 2002;47: 455-468 DOI ScienceOn |
11 | Feng D, Ho D, Chen K. An evaluation of the algorithms for determining local cerebral metabolic rates of glucose using positron emission tomography dynamic data. IEEE Trans Med Imaging. 1995;14: 697-710 DOI ScienceOn |
12 | Huang SC, Carson RE, Phelps ME. Measurement of local blood flow and distribution volume with short-lived isotopes: a general input technique. J Cereb Blood Flow Metab. 1982;2: 99-108 DOI PUBMED |
13 | Feng D, Huang S-C. Wang Z, Ho D. An unbiased parametric imaging algorithm for nonuniformly sampled biomedical system parameter estimation. IEEE Trans Med Imaging. 1996;15: 512-518 |
14 | Kety SS. Measurement of local blood flow by the exchange of an inert, diffusible substance. Methods Med Res. 1960;8: 228-236 |
15 | Phelps ME, Mazziotta J, Schelbert H. Positron emission tomography and autoradiography: principle and application for the brain and heart. NY: Raven Press;1986 |
16 | Carson RE, Huang SC, Green MV. Weighted integration method for local cerebral blood flow measurements with positron emission tomography. J Cereb Blood Flow Metab. 1986;6: 245-258 DOI PUBMED |
17 | Feng D, Ho D, Lau KK, Siu WC. GLLS for optimally sampled continuous dynamic system modeling: theory and algorithm. Comput Methods Programs Biomed. 1999;59: 31-43 DOI ScienceOn |
18 | Koeppe RA, Holthoff VA, Frey KA, Kilbourn MR, Kuhl DE. Compartmental analysis of [11C]flumazenil kinetics for the estimation of ligand transport rate and receptor distribution using positron emission tomography. J Cereb Blood Flow Metab. 1991;11: 735-744 DOI PUBMED |
19 | Kimura Y, Hsu H, Toyama H, et al. Improved signal-to-noise ratio in parametric images by cluster analysis. Neuroimage. 1999;9: 554-561 DOI ScienceOn |
20 | Huang SC, Carson RE, Hoffman EJ, et al. Quantitative measurements of local cerebral blood flow in humans by positron emission tomography and O-15 water. J Cereb Blood Flow Metab. 1983;3: 141-153 DOI PUBMED |
21 | Marquardt DW. An algorithm for least squares estimations of nonlinear parameters. J Soc Indust Appl Math. 1963;11: 431-441 DOI ScienceOn |
22 | Iida H, Bloomfield PM, Miura S, et al. Effect of real-time weighted integration system for rapid calculation of functional images in clinical positron emission tomography. IEEE Trans Med Imaging. 1995;14: 116-121 DOI ScienceOn |
23 | Bard Y. Nonlinear parameter estimation. NY: Academic Press;1974 |