A Study on the Probabilistic Safety Assessment and Sensitivity Analysis of Success Criteria of Large LOCA for APR+  

Moon, Horim (Korea Hydro & Nuclear Power Co., LTD., Central Research Institute)
Kim, Han Gon (Korea Hydro & Nuclear Power Co., LTD., Central Research Institute)
Publication Information
Journal of the Korean Society of Safety / v.31, no.6, 2016 , pp. 129-134 More about this Journal
Abstract
Standard design of APR+(advanced power reactor plus) was certified at 2014 by Korea regulatory body. Based on the experience gained from OPR1000 and APR1400, the APR1400 was being developed as a 1,500MWe class reactor using Korean technologies for design code, reactor coolant pump, and man-machine interface system. APR+ has been basically designed to have the seismic design basis of safe shutdown earthquake (SSE) 0.3g, a 4-train safety concept based on N+2 design philosophy, and a passive auxiliary feedwater system (PAFS). Also, safety issues on the Fukushima-type accidents have been extensively reviewed and applied to enhance APR+ safety. APR+ provides higher reliability and safety against tsunami and earthquake. The purpose of this paper is to implement probabilistic safety assessment considering these design features and to analyze sensitivity of core damage frequency for large loss of coolant accident of APR+.
Keywords
APR+; probabilistic safety analysis; core damage frequency; passive auxiliary feedwater system;
Citations & Related Records
연도 인용수 순위
  • Reference
1 KHNP, "APR+ Standard Safety Aalysis Report," 2011.
2 H. R. Moon, "Technical Report on Safety Analysis for the APR+", KHNP Central Research Institute, 2013.
3 NUREG/CR-2300, "PRA Procedures Guide-A guide to the performance of probabilistic risk assessment for Nuclear Power Plants," U.S. Nuclear Regulatory Commission, Vol. 1 & 2, 1982.
4 NUREG/CR-2815, "Probabilistic Safety Analysis Procedures Guide," U.S. Nuclear Regulatory Commission, 1984.
5 NUREG/CR-5750, "Rates of Initiating Events at US Nuclear Power Plants: 1987-1995," INEEL, 1999.
6 "Advanced Light Water Reactor Utility Requirements Document," Rev.7, EPRI, 1995.
7 KHNP, "Probabilistic safety Analysis for Shin-Kori 34," 2011.
8 H. R. Moon at el., "The Sensitivity Analysis for Applying Gas Turbine Generator to Alternate Alternating Current in APR+," Transactions of the Korea Society of Mechanical Engineers, Part A, Vol. 36, No. 1, pp. 97-102, 2012.
9 NUREG-1150, "Severe Accident Risks: An Assessment for Five U.S. Nuclear Power Plants," Vols. 1 and 2, Final Summary Report, U.S. Nuclear Regulatory Commission, 1990.
10 KHNP, "APR1400 Standard Safety Analysis Report," 2001.
11 U.S. Nuclear Regulatory Commission, RELAP5/MOD3.3 Code Manual," 2003.
12 NUREG/CR-6928, "Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants," U.S. Nuclear Regulatory Commission, "Industry Average Parameter Estimates, 2010 Update," http://nrcoe.inl.gov/resultsdb/AvgPerf, 2012.