Design of Integrated Safery System for Sealed Places  

Jeong, Min-Seung (Department of Computer Engineering, Pukyong National University)
Lee, Chang-Shin (Conis)
Cho, Woo-Hyeon (Department of Computer Engineering, Pukyong National University)
Abstract
Disaster accidents at industrial sites have been increasing every year. In shipyards there are countless enclosed spaces causing issues like harmful-toxic gases stuck in those sealed areas. And due to such special and complicated structures of the working places with many layers of walls separating each other, there exist more issues of communication with workers trapped inside when accidents happen. Under this circumstance there must be a huge difficulty to evacuate or rescue the workers in case of any disaster. Therefore, in this paper, We would like to introduce the "integrated safety system" to more effectively deal with the problems and prevent such disasters in tough working environments. The suggested integrated safety system can prevent accidents in advance because it can control the data on the location of the workers in real time and the numerical values such as gas, oxygen, and carbon dioxide generated in the workplace in real time.
Keywords
LoRa Communication; Mesh; Evacuation; Standing Operating Procedure; Disaster;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Electronics And Telecommunications Research Institute, "Technology of Portable Gas Measurement System in a Enclosure," Technical Report, 2015.
2 T. H. Yoon, W. S. Jung, D. S. Yoo, and H. K. Choi, "LoRaWAN Class Yard : Development of LoRaWAN Relay System to overcome Radio Shadow Area," Proceedings of the KICS 2018 Summer General Conference, pp. 724-725, July 2018.
3 Y. J. Choi, and H. Choi, "Accident Prevention in Confined Space Using IoT Technology", Journal of the korea Institute of Information and Communication Engineering, vol. 22, no. 9, pp. 1159-1164, September 2018.   DOI
4 T. W. Kim, "Power Supply Characteristic of IoT Electrical Safety Mornitoring Device according to the LoRa Technology," Proceedings of the KIEE 2016 Spring Conference, pp. 256-257, October 2016.
5 D. H. Ryu, "A Development of Protable Mesh Network Gateway for Disaster Relief," The Journal of the Institute of Internet Broadcasting and Communication, vol. 11, no. 3, pp. 99-105, June 2011.   DOI
6 J. H. Ko, D. K. Han, S. R. Lee, H. Y. Park, and D.H. Kim, "Implementation of GPS-based Wireless Loss Prevention System using the LoRa Module," Journal of Digital Contents Society, vol. 18, no. 4, pp. 761-768, July 2017.   DOI
7 Ministry of Public Administration and Security, "Disaster response standard operating procedure (SOP) - Policy research and information service," Dongguk University Industrial Cooperation Group, Technical Report, 2012.
8 K. U. Jung. (2016, October). An Analysis of Technology Trends for Ubiquitous Computing. [Internet]. Available: http://www.ubiu.net/board/view.php?id=u_trend&page=1&sn1=&divpage=1&sn=off&ss=on&sc=on&select_arrange= headnum&desc=asc&no=3.