Browse > Article
http://dx.doi.org/10.6109/jkiice.2016.20.11.2100

An Implementation of Remote Monitoring System for Control Relay  

Chang, Yong-Hoon (Department of Emergency Medical Technology, Dongju College)
Nam, Jae-hyun (Department of Computer Education, Silla University)
Abstract
The automation system uses PLC to monitor the manufacturing process status of the production product and processes the sensor information transmitted from the sensor. In this paper, we propose a remote surveillance system to monitor the status of control relay used in automation system. The proposed system consists of a control relay module, a one-chip processor module, a computer monitoring system, and a database system that inputs and manages the details of the control relay. The computer monitoring system is configured to monitor the operating condition and life time of the control relay. The database is configured so that the input date of the control relay can be input and corrected, and the operating state information of the control relay can be automatically printed. In the remote monitoring system, the failure status of the control relay is recognized in real time, and the time required for normal operation can be minimized by quickly replacing faulty parts.
Keywords
Automatic control; Control Relay; One-chip; Remote; Data-Base; Real-time monitoring;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 I. S. Han, "Mechanical Life Prediction of a Relay by Accelerated Life Tests," Master Thesis, Department of Industrial Engineering Graduate School, Chongju University, Feb. 2004.
2 Y. H. Chang and J. H Nam, "Implementation of Diagnostic Monitoring System for Auxiliary Relay," in Conference on Korea Information and Communication Engineering, vol. 20, no. 2, pp.709-711, 2016.
3 Y. I. Kwon, and I. S. Han,"Mechanical Life Prediction of a Relay by Accelerated Life Tests," in Proceedings of the Korean Reliability Society Conference, vol. 9, pp.75-82, June 2005.
4 K. B. Lee, "Electrical Life Estimation of Electromagnetic Relays by Accelerated Test(ALT)," Master Thesis, Dept. of Safety Engineering Graduate School of Industry and Engineering, Seoul National University, Feb. 2010.
5 S. H. Ji, S. H. Kim, S. W. Heo, and D. S. Rho, "Evaluation Algorithm for Coordination Protection Between Substation Relay and Recloser," in Proceedings of the Korea Academia-Industrial Cooperation Society Fall Conference, vol. 29, pp.17-20, 2011.
6 KSC 4520, "Hinge Type Electronic Relay," Korean Standards Association, 1992.
7 C. K. Kim, I. K. Lee, and S. H. Cho, "Study for Failure Examples of Solenoid Valve, Relay and Idle Control Actuator in Liquid Petroleum Gas vehicle Engines," Journal of the Korean Institute of Gas, vol. 15, no. 3, pp.47-52, June 2011.   DOI