A Study on the Elevator Overbalance-Ratio Control and Improved Scheme for Safety  

Lee, Ho-Cheol (Department of Electronic & Electrical Engineering, Pusan National University)
Choi, Young-Kiu (Department of Electrical Engineering, Pusan National University)
Abstract
An elevator is driven by the friction between the pulley and wire rope. A balancing counter weight is connected to the elevator car with a wire rope. This structure is essential to drive elevators while it always has weight unbalance problems on each side. The overbalance-ratio of elevators may be an important factor for safety and structural efficiency; however, it is not yet clearly defined in the Requirements of Korea Elevator Inspection. This paper describes these "weight unbalance ratio" for control of elevators to reduce the number of accidents. It includes the analysis of current elevator maintenance situations and also proposes some fundamental improvement schemes for safety.
Keywords
elevator; overbalance-ratio; safety; requirements of inspection;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Korea Elevator Safety Institute, "Korea Elevator History for 100 Years", 2010.
2 Ministry of Security and Public Administration, "A Study on the Elevator Safety Inspection Improvement based on the Accident Cases", 2009.
3 Winfried Quadfasel, Brakes for Lift Systems, pp. 2-3, March 2004.
4 Kyung-Taek Chung, Dong-Bok Kim, "An Experimental Study of Spring Acting Rope Brake for Lift", SARK Summer conference, pp. 1258-1261, 2011.
5 Joosup Jang, "Design Parameters Considering Friction Characteristics for Rope Brake System of Elevator", KSTLE, vol. 29, No. 3, pp. 171-179, June 2013.   과학기술학회마을   DOI   ScienceOn
6 K. Rajaraman and S. K. Nagaraja, "An elevator speed-control system using squirrel-cage induction motors," IEEE Transactions on Industrial Electronics, vol. IE-31, no.2, pp.164-167, May 1984.   DOI   ScienceOn
7 Hiromi Inaba, K. Hirasawa, Takeki Ando, Mitsuyuki Hombu, and M. Nakazato, "Development of a high-speed elevator controlled by current source inverter system with sinusoidal input and output", IEEE Transactions on Industry Applications, vol. 28, no. 4, July 1992.
8 N. Mutoh, N. Ohnuma, A. Omiya, and M. Konya, "A motor driving controller suitable for elevators," IEEE Transactions on Power Electronics, vol. 13, no. 6, pp. 1123-1134, Nov, 1998.   DOI   ScienceOn
9 D.N. Dyck and P.E. Caines, "The logical control of an elevator," IEEE Transactions on Automatic Control, vol. 40, no. 3, pp. 480-486, Mar 1995.   DOI   ScienceOn