Browse > Article
http://dx.doi.org/10.7837/kosomes.2015.21.4.437

A Study on the HSE Monitoring System based on Smart Device for Establishing Evaluation System of the Combined Safety Index  

Woo, Jong-Hun (Department of Naval Architecture and Ocean Systems Engineering, Korea Maritime and Ocean University)
Lim, Hyun-Kyu (Department of Naval Architecture and Ocean Systems Engineering, Korea Maritime and Ocean University)
Youn, Kyung-Won (Department of Naval Architecture and Ocean Systems Engineering, Korea Maritime and Ocean University)
Ham, Dong-Kyun (Department of Naval Architecture and Ocean Systems Engineering, Korea Maritime and Ocean University)
Publication Information
Journal of the Korean Society of Marine Environment & Safety / v.21, no.4, 2015 , pp. 437-448 More about this Journal
Abstract
In this paper, smartphone based measuring device was developed by integration of several sonsors such as moving, temperature, pulsation, respiration and hearing and sever/client programs was developed for the data acquisition and communication between smartphone and server computer. Then, the concept of CSI(combined safety index) was proposed for the comprehensive diagnositcs of workers status. For the validation of the proposed concept, the real data was acquired by boarding at training ship of korea maritime and ocean university. The acquired data was analyzed with the stochastical method of regressionn, then the meaningful result was driven that could explain the relation between the risky situation and the measured chronical data.
Keywords
Biometrics; CSI(Combined safety index); HSE(Health; Safety and Environment); Offshore plant; Smart device;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Jeon, J. A., N. S. Kim, J. G. Go, T. J. Park, H. Y. Gang and C. S. Pyo(2014), IoT device product and technology trend, Journal of The Korean Institute of Communication and Information Sciences, Vol. 31, No. 4, pp. 44-52.
2 Jung, J. W.(2001), Building on Internet Survey System Using Apache PHP Mysql and Application to Webmining, Hanyang University, Seoul, Korea, pp. 1-28.
3 Jung, S. J.(2013), Mobile Healthcare System using Wearable Physiological Sensors in Global M2M Networks, Pukyong National University, Busan, Korea, pp. 1-186.
4 Lee, H. S. and J. H. Im(2015), SPSS 22 Manual, Seoul, Korea, JypHuunJae, pp. 298-363.
5 Oh, H. S., S. R. Chang and D. J. Kim(2013), Smart Work Based Development of HSE Management System, Bulletin of the Society of Naval Architects of Korea, Vol. 50, No. 2, pp. 38-43.
6 Park, J. Y., H. S. Oh and S. Y. Moon(2013), Smart Device Based Quality Management and Process Management of Shipyard Production, Bulletin of the Society of Naval Architects of Korea, Vol. 50, No. 2, pp. 26-32.
7 Park, S. T.(2005), A study for Understanding of Actual Condition and Prevention Countermeasures Regarding Industrial Disaster in Shipbuilding Industry, Ulsan University, Ulsan, Korea, pp. 1-56.
8 Statistical Data of Shipbuilding Industrial Disaster(2015), http://www.bls.gov/iif/.
9 Woo, J. H., M. J. Sung and G. H. Kim(2013), Research on the HSE Application with Smart Device and Biometrics, Proceedings of the Society of CAD/CAM Engineers Conference, pp. 259-267.
10 Yoo, K. M., H. H. Park and K. J. Chung(2009), A Study on Statistics for Accidents in Confined Space in Korea, Korean Industrial Hygiene Association Journal, Vol. 19, No. 4, pp. 363-369.
11 Yun, W. J., Y. S. Ro and S. B. Cho(2010), A Study on Safety System for Blasting Workers using Real Time Location System in the Shipyard, Journal of the Society of Naval Architects of Korea, Vol. 47, No. 6, pp. 836-842.   DOI   ScienceOn
12 Global smartphone subscriptions to reach 5.6 billion by 2019(2013), Ericsson Mobility Report, http://www.ericsson.com.
13 Heo, J. W.(2010), The Implementation of The Optimum Production Process Management System By The Manufacturing Execution System Solution, Ulsan University Library, Ulsan, Korea, pp. 1-43.
14 Industrial accident rate and death 10-thousand person rate(2015), http://www.kosha.or.kr/board.do?menuId=554.